Low voltage 16mm 25mm 35mm 50mm 70mm Cu / Al xlpe insulated waterproof electrical cable wire

Low voltage 16mm 25mm 35mm 50mm 70mm Cu / Al xlpe insulated waterproof electrical cable wire
Port: Shanghai/Qingdao/Dalian/Guangzhou/Ningbo
Payment Terms: L/C,T/T,Western Union,MoneyGram,Paypal
Supply Ability: 10 Kilometer/Kilometers per Day other electrical cable MOQ depending on the specifications.
Place of Origin: Henan China
Brand Name: Hongda
Model Number: YJV/N2XY
Insulation Material: XLPE
Type: Low Voltage
Application: Overhead
Conductor Material: Copper
Jacket: PVC
Conductor: Copper
Sheath color: Black or as per requirement
electrical cable Rated voltage: 0.6/1KV
Insulation thickness: 1.8mm
Cable approx. weight: 8743.0 kg/km
Nominal cross section area of Conductor: 5x150mm2
electrical cable Approx. dia of cable: 58.6mm
Test Voltage: 3.5kv
Packing: in drums, or in coils
Certificate: ISO CCC
Packaging Detail: The electrical cable package are export wooden drum, wooden iron drum and other export standard package

Low voltage 16mm 25mm 35mm 50mm 70mm Cu / Al xlpe insulated waterproof electrical cable wire

Cables insulated with PE or PVX

NYY, NYY FLEX, NYY-fl, NYY-fl FLEX, NYY-LS, NYY-LS FLEX, NAYY, NAYY-fl, NAYY-LS, N2XY, N2XY-fl, N2XY-LS, NA2XY,NA2XY-fl,NA2XY-LS

Area of application: NYY (NAYY) electrical cables intended for transmission and distribution of electric power in fixed installations at rated voltage of 0.66, 1.0, 3.0 and 6.0 kV at 50 Hz frequency or DC voltage up to 1.0 kV. Hongda Electrical cables are designed for use on land, rivers and lakes at altitudes up to 4300 m above sea level. And also for installation in dry and wet industrial premises, special cable racks, in blocks, as well as for installation in the open air. Cables are not recommended for in ground installation(in trenches).

 

Technical parameters:

  • Rated operational voltage – 0.66/1.0 kV
  • Number of cores – 1, 2, 3, 4, 5
  • Ambient temperature during use of wire: -50°C +50°C
  • Relative humidity: 98% at 35°C temperature
  • Service life: 50 years

Construction

  • Conductor – aluminum or copper
  • PVC or cross-linked polyethylene insulation
  • PE or PVX sheath

Parameters

Wire forming cores, lateral section Nominal cross-section area, mm
Circular Profiled
Single wire core 1,5 – 10
Multiwire core 16 – 240 70 – 240

Click and Ask for Price

 

Shielded Electrical Cable

NYCY, NYCY-fl, NYCY-LS, NAYCY, NAYCY-fl, NAYCY-LS

Area of application: NYCY, NYCY-fl, NYCY-LS, NAYCY, NAYCY-fl, NAYCY-LS electrical cables are designed for transmission and distribution of electrical power in fixed installations that require a high level of electrical and mechanical protection, for rated voltages up to 1.0 kV nominal frequency of 50Hz. Cables are designed for both single and group laying in production areas and protection of electrical circuits from the influence of external electric fields.

 

Nominal cross sectional area of electrical cable

Wire forming cores, lateral section Nominal cross-section area, mm
Circular Profiled
Single wire core 1,5 – 10
Multiwire core 16 – 240 70 – 240

 

Construction

  • 1. Conductor – aluminum or copper.
  • 2. PVC or XLPE insulation.
  • 3. Belt insulation – polyvinylchloride elastron.
  • 4. Shield of copper wires (or copper tape).
  • 5. Copper tape.
  • 6. PVC or PE sheath

Technical parameters:

  • Rated operational voltage – 0,66/1,0 kV
  • Number of cores – 1, 2, 3, 4, 5
  • Ambient temperature during use of wire: -50°C +50°C
  • Relative humidity: 98% at 35°C temperature
  • Service life: 30 years

Click and Ask for Price

 

Armored Electrical Cable

NYBY, NYBY-fl, NYBY-LS, NYB2Y, N2XBY, N2XBY-fl, N2XBY-LS, N2XB2Y, N2XB(F)2Y, NAYBY, NAYBY-fl, NAYBY-LS, NAYB2Y, NA2XBY, NA2XBY-fl, NA2XBY-LS, NA2XB2Y, NA2XB(F)2Y

Area of application: NYY (NAYY) electrical cables intended for transmission and distribution of electric power in fixed installations at rated voltage of 0.66, 1.0, 3.0 and 6.0 kV at 50 Hz frequency. Hongda Electrical cables are designed for use on land, rivers and lakes at altitudes up to 4300 m above sea level. And also for installation in dry and wet industrial premises, special cable racks, in blocks, as well as for installation in the open air. Elelctrical Cables are not recommended for in ground installation(in trenches).

 

Technical parameters:

  • Number of cores – 1, 2, 3, 4, 5.
  • Operating temperature range from -50°C to +50°C.
  • Relative humidity: 98% at 35°C temperature
  • Service life: 30 years

Construction

  • Conductor – aluminum or copper.
  • PVC or XLPE insulation.
  • Belt insulation – polyvinylchloride elastron.
  • Armour: galvanized steel tape for cover or galvanized steel wire for cover.
  • PE or PVX sheath.

Nominal cross sectional area of electrical cable

Wire forming cores, lateral section Nominal cross-section area, mm
Circular Profiled
Single wire core 1,5 – 10
Multiwire core 16 – 240 70 – 240

Click and Ask for Price

 

 

1>. Power Cables (Armoured / Unarmoured – PVC / XLPE)

Hongda Cable manufactures a wide range of Armoured Cables, Armoured Power Cables, Armoured Electrical Cables, PVC Armoured Cables and XLPE Armoured Cables. XLPE means cross-linked polyethylene or vulcanized polyethylene. The basic material is low density polyethylene. Polyethylene is a thermoplastic material consisting of long chain of hydrocarbon molecules. At elevated temperatures these molecules tend to move relative to one another so that the material becomes increasingly deformable and will eventually melt at the temperature around 110°C.

By means of process similar to the vulcanization of rubber the polyethylene molecules can be cross-linked. The process of cross-linking or vulcanization consists of producing chemical bonds at interval between the long molecular chain to give a “ladder” effect which prevents slippage between molecules as a result of cross-linking the material becomes heat resistant and does not soften at higher temperatures. Further it has better resistance to stress cracking and good resistance to ageing in hot air. With the change of structure there is no adverse effect on electrical properties.

Advantage of “HONGDA CABLE” XLPE Cables

  • Dielectric losses are very small
  • Higher current carrying capacity
  • Higher short circuit rating 250°C as against 160°C for PVC
  • “HONGDA CABLE” XLPE can retain flexibility down upto – 40°C
  • Jointing and Termination is easy
  • Light in weight
  • They are not prone to fatigue damages due to vibrations or loading cycles
  • Has better resistance to most chemicals, oils, acids, etc
  • Can be installed along cable routes without elevation limitations

Comparison of Main Properties Between PVC and XLPE Insulation

Characteristics Unit PVC XLPE
Permitivity (50Hz , 20°C) 4 – 6 2.3
Dielectric loss factor (50Hz, 20°C) 0.05 – 0.07 0.0004
Volume resistivity (27°C) Ohms cm (min.) 1×1013 1×1014
Max. conductor temp. °C 70 90
Max. short circuit temp. °C 160 250
Tensile strength N / mm2 (min.) 12.5 12.5
Elongation at break Excellent Medium
Flexibility at -10°C Poor Good
Resistance to abrasion Medium Good

 

Click and Ask for Price

 

 

2>. Control Cables (Armoured / Unarmoured – PVC / XLPE)

A wide range of Control Cables (PVC Insulated & Sheathed Flexible Cables) are available with us. These control cables have high tensile strength and accurate resistance to high temperatures. These cables work in both dry and moist conditions. We offer them in black/gray core colours and gray, black and white sheer colours. They are highly flexible for application in different electrical environment. These control cables used in tool machines, steel production units, electrical substations etc.

 

Technical Specifications
Core colours Black / grey with reverse colour numbering + yellow / green
Sheath colour Grey, Black and white
Conductor Annealed Bare Copper as per IS : 8130
PVC Insulation Type A conforming to IS:5831
PVC Sheath Type ST-1 conforming to IS :5831 HR, FR & FRLS sheathing as per requirement
Rated voltage 650/1100V
Test Voltage 2000 V.A.C.
Min. bending radius 4 time overall diameter of cable
Tensile strength 12.50 N per sq.mm of PVC insulation and sheath
Max. working temperature 70°C, also available for 85°C as per requirement
Max short circuit temperature 160°C
Minimum Laying Temperature 15°C
Use :- These cables are used for flexible use for medium mechanical stredded with free movement without tensile stress in dry and moist condition for measuring and control in tool machines, conveyor belts, production lines in machinery production, steel production and electrical substations.

 

Yes! I am Interested

 

 

Standards

IEC60502-2,IEC60332,IEC60754,and other standards just as BS ,DN, or the standard required by the clients.

 

The type of cable and applying   0.6/1kV

Type

Name

Applying bound

YJV

Copper XLPE insulated PVC 

sheathed power cable

Mainly laid at indoor, cable slot, tube and 

other places which do not endured heavy pressure

YJLV

Aluminum XLPE insulated PVC 

sheathed power cable

YJY

Copper XLPE insulated PE 

sheathed power cable

YJLY

Aluminum XLPE insulated PE 

sheathed power cable

YJV22

Copper XLPE insulated steel tape armored PVC 

sheathed power cable

Mainly laid at indoor, cable slot, tube and 

other places which endured heavy pressure

YJLV22

Aluminum XLPE insulated steel tape armored PVC 

sheathed power cable

YJV23

Copper XLPE insulated steel tape armored PE 

sheathed power cable

YJLV23

Aluminum XLPE insulated steel tape armored PE 

sheathed power cable

YJV32

Copper XLPE insulated fine steel wire armored PVC 

sheathed power cable

Be laid vertically and could endure heavy pressure

YJLV32

Aluminum XLPE insulated fine steel wire armored PVC 

sheathed power cable

YJV33

Copper XLPE insulated fine steel wire armored PE 

sheathed power cable

YJLV33

Aluminum XLPE insulated fine steel wire armored PE 

sheathed power cable

YJAV

Copper conductor XLPE insulated integrate waterproof 

sheathed power cable

Mainly laid at indoor, cable slot, tube and 

moisture place which  do not endure heavy pressure

YJLAV

Aluminum conductor XLPE insulated integrate waterproof 

sheathed power cable

 

The Nominal Cross section area of conductor we can do:

1×1.5mm2 ~ 1x800mm2

2×2.5mm2 ~ 2x400mm2

3×1.5mm2 ~ 3x400mm2

5×1.5mm2 ~ 5x400mm2

 

3×4+1×2.5mm2 ~ 3×400+1x240mm2

3×4+2×2.5mm2 ~ 3×400+2x240mm2

4×4+1×2.5mm2 ~ 4×400+1x240mm2

 

 

 

Application:

 

 

Company & Certification:

 

The package of  XLPE electrical cable.

1. Export wooden drum, wooden iron drum and other export standard package

2. Each Drum 100m or depending on customized.

3. Then pack by plastic kitting bag or plastic film.

4. Fixed with plank or board.

 

Any other information of cables pls contact with me:

Tags: , ,

Contact us

 

 

 