N2XY / N2XWY 4 core 35mm2 XLPE insulation copper electrical cable

N2XY / N2XWY 4 core 35mm2 XLPE insulation copper electrical cable
Port: Shanghai/Qingdao/Dalian/Guangzhou/Ningbo
Payment Terms: L/C,T/T,Western Union,MoneyGram,Paypal
Supply Ability: 15 Kilometer/Kilometers per Day other electrical cable MOQ depending on the specifications.
Place of Origin: Henan China
Brand Name: Hongda
Model Number: N2XY/N2XWY
Insulation Material: XLPE
Type: Low Voltage
Application: Construction
Conductor Material: Copper
Jacket: PVC
Conductor: Copper
Sheath color: Black or as per requirement
Rated voltage: 0.6/1KV
Insulation thickness: 1.8mm
Cable approx. weight: 8743.0 kg/km
Nominal cross section area of Conductor: 5x150mm2
Approx. dia of cable: 58.6mm
Test Voltage: 3.5kv
Packing: in drums, or in coils
Certificate: ISO CCC
Packaging Detail: The electrical cable package are export wooden drum, wooden iron drum and other export standard package

N2XY / N2XWY 4 core  35mm2 XLPE insulation copper electrical cable

 

1>. Power Cables (Armoured / Unarmoured – PVC / XLPE)

Hongda Cable manufactures a wide range of Armoured Cables, Armoured Power Cables, Armoured Electrical Cables, PVC Armoured Cables and XLPE Armoured Cables. XLPE means cross-linked polyethylene or vulcanized polyethylene. The basic material is low density polyethylene. Polyethylene is a thermoplastic material consisting of long chain of hydrocarbon molecules. At elevated temperatures these molecules tend to move relative to one another so that the material becomes increasingly deformable and will eventually melt at the temperature around 110°C.

By means of process similar to the vulcanization of rubber the polyethylene molecules can be cross-linked. The process of cross-linking or vulcanization consists of producing chemical bonds at interval between the long molecular chain to give a “ladder” effect which prevents slippage between molecules as a result of cross-linking the material becomes heat resistant and does not soften at higher temperatures. Further it has better resistance to stress cracking and good resistance to ageing in hot air. With the change of structure there is no adverse effect on electrical properties.

Advantage of “HONGDA CABLE” XLPE Cables

  • Dielectric losses are very small
  • Higher current carrying capacity
  • Higher short circuit rating 250°C as against 160°C for PVC
  • “HONGDA CABLE” XLPE can retain flexibility down upto – 40°C
  • Jointing and Termination is easy
  • Light in weight
  • They are not prone to fatigue damages due to vibrations or loading cycles
  • Has better resistance to most chemicals, oils, acids, etc
  • Can be installed along cable routes without elevation limitations

Comparison of Main Properties Between PVC and XLPE Insulation

Characteristics Unit PVC XLPE
Permitivity (50Hz , 20°C) 4 – 6 2.3
Dielectric loss factor (50Hz, 20°C) 0.05 – 0.07 0.0004
Volume resistivity (27°C) Ohms cm (min.) 1×1013 1×1014
Max. conductor temp. °C 70 90
Max. short circuit temp. °C 160 250
Tensile strength N / mm2 (min.) 12.5 12.5
Elongation at break Excellent Medium
Flexibility at -10°C Poor Good
Resistance to abrasion Medium Good

 

Click and Ask for Price

 

 

NYCY, NYCY-fl, NYCY-LS, NAYCY, NAYCY-fl, NAYCY-LS

Area of application: NYCY, NYCY-fl, NYCY-LS, NAYCY, NAYCY-fl, NAYCY-LS cables are designed for transmission and distribution of electrical power in fixed installations that require a high level of electrical and mechanical protection, for rated voltages up to 1.0 kV nominal frequency of 50Hz. Cables are designed for both single and group laying in production areas and protection of electrical circuits from the influence of external electric fields.

 

Nominal cross sectional area of cable

Wire forming cores, lateral section Nominal cross-section area, mm
Circular Profiled
Single wire core 1,5 – 10
Multiwire core 16 – 240 70 – 240

Construction

1. Conductor – aluminum or copper.

2. PVC or XLPE insulation.

3. Belt insulation – polyvinylchloride elastron.

4. Shield of copper wires (or copper tape).

5. Copper / Steel tape.

6. PVC or PE sheath

 

Technical parameters:

  • Rated operational voltage – 0,66/1,0 kV
  • Number of cores – 1, 2, 3, 4, 5
  • Ambient temperature during use of wire: -50°C +50°C
  • Relative humidity: 98% at 35°C temperature
  • Service life: 30 years

 

 

Yes! I am Interested

 

 

Standards

IEC60502-2,IEC60332,IEC60754,and other standards just as BS ,DN, or the standard required by the clients.

 

The type of cable and applying   0.6/1kV

Type

Name

Applying bound

YJV

Copper XLPE insulated PVC 

sheathed power cable

Mainly laid at indoor, cable slot, tube and 

other places which do not endured heavy pressure

YJLV

Aluminum XLPE insulated PVC 

sheathed power cable

YJY

Copper XLPE insulated PE 

sheathed power cable

YJLY

Aluminum XLPE insulated PE 

sheathed power cable

YJV22

Copper XLPE insulated steel tape armored PVC 

sheathed power cable

Mainly laid at indoor, cable slot, tube and 

other places which endured heavy pressure

YJLV22

Aluminum XLPE insulated steel tape armored PVC 

sheathed power cable

YJV23

Copper XLPE insulated steel tape armored PE 

sheathed power cable

YJLV23

Aluminum XLPE insulated steel tape armored PE 

sheathed power cable

YJV32

Copper XLPE insulated fine steel wire armored PVC 

sheathed power cable

Be laid vertically and could endure heavy pressure

YJLV32

Aluminum XLPE insulated fine steel wire armored PVC 

sheathed power cable

YJV33

Copper XLPE insulated fine steel wire armored PE 

sheathed power cable

YJLV33

Aluminum XLPE insulated fine steel wire armored PE 

sheathed power cable

YJAV

Copper conductor XLPE insulated integrate waterproof 

sheathed power cable

Mainly laid at indoor, cable slot, tube and 

moisture place which  do not endure heavy pressure

YJLAV

Aluminum conductor XLPE insulated integrate waterproof 

sheathed power cable

 

The Nominal Cross section area of conductor we can do:

1×1.5mm2 ~ 1x800mm2

2×2.5mm2 ~ 2x400mm2

3×1.5mm2 ~ 3x400mm2

5×1.5mm2 ~ 5x400mm2

 

3×4+1×2.5mm2 ~ 3×400+1x240mm2

3×4+2×2.5mm2 ~ 3×400+2x240mm2

4×4+1×2.5mm2 ~ 4×400+1x240mm2

Unarmoured PVC Control Cable
No. of Cores & Cross Sectional Area No. x mm2 Thickness of PVC Insulation (Nom.) mm Thickness of Innersheath (min.) extruded mm Thickness of Outersheath (nom.) mm Approx. O.D. Mm Approx. Net Weight of Cable Kg/Km Standard Delivery Length in Mtrs. Current Rating
Direct in Ground Amps In Air / Duct. Amps
2C x 1.5 0.8 0.3 1.8 11.8 185 1000 23 20
3C x 1.5 0.8 0.3 1.8 12.3 190 1000 21 17
4C x 1.5 0.8 0.3 1.8 13.2 225 1000 21 17
5C x 1.5 0.8 0.3 1.8 14.1 260 1000 16 14
6C x 1.5 0.8 0.3 1.8 15.1 295 1000 15 13
7C x 1.5 0.8 0.3 1.8 15.1 315 1000 14 13
10C x 1.5 0.8 0.3 1.8 18.4 425 1000 13 11
12C x 1.5 0.8 0.3 1.8 18.9 480 1000 12 10
14C x 1.5 0.8 0.3 1.8 19.8 535 1000 11 10
16C x 1.5 0.8 0.3 1.8 20.7 595 1000 11 9
19C x 1.5 0.8 0.3 2.0 22.5 720 1000 10 9
24C x 1.5 0.8 0.3 2.0 25.8 880 1000 9 8
27C x 1.5 0.8 0.3 2.0 26.3 960 1000 9 8
30C x 1.5 0.8 0.3 2.0 27.2 1040 1000 9 7
37C x 1.5 0.8 0.3 2.0 29.1 1230 1000 8 7
2C x 2.5 0.9 0.3 1.8 13.0 230 1000 32 27
3C x 2.5 0.9 0.3 1.8 13.6 240 1000 27 24
4C x 2.5 0.9 0.3 1.8 14.6 290 1000 27 24
5C x 2.5 0.9 0.3 1.8 15.7 335 1000 23 19
6C x 2.5 0.9 0.3 1.8 16.9 385 1000 21 18
7C x 2.5 0.9 0.3 1.8 16.9 420 1000 20 17
10C x 2.5 0.9 0.3 1.8 20.8 570 1000 18 15
12C x 2.5 0.9 0.3 2.0 22.2 690 1000 17 14
14C x 2.5 0.9 0.3 2.0 23.2 775 1000 16 13
16C x 2.5 0.9 0.3 2.0 24.3 860 1000 15 13
19C x 2.5 0.9 0.3 2.0 25.5 985 1000 14 12
24C x 2.5 0.9 0.3 2.0 29.4 1215 1000 13 11
27C x 2.5 0.9 0.3 2.0 30 1330 1000 12 10
30C x 2.5 0.9 0.3 2.0 31 1450 1000 12 10
37C x 2.5 0.9 0.4 2.2 34.1 1790 1000 11 9

 

 

The package of  XLPE electrical cable.

1. Export wooden drum, wooden iron drum and other export standard package

2. Each Drum 100m or depending on customized.

3. Then pack by plastic kitting bag or plastic film.

4. Fixed with plank or board.

 

 

 

Any other information of cables pls contact with me:

 

Tags: , ,