VVG VBbShv VVng-LS VBbShvng-LS AVVG AVBbShv AVBbShvng-LS power cable

VVG VBbShv VVng-LS VBbShvng-LS AVVG AVBbShv AVBbShvng-LS power cable
Port: QINGDAO SHANGHAI
Payment Terms: L/C,T/T
Supply Ability: 1800 Kilometer/Kilometers per Month 0.6/1kV XLPE cable XLPE insulated pvc sheathed power cable
Place of Origin: Hainan China
Brand Name: hongda
Model Number: Russian strandard power cable
Insulation Material: XLPE
Type: Low Voltage
Application: Overhead
Conductor Material: Copper
Jacket: PVC
MODEL MUNBER: VVG,VBbShv,VVng-LS,VBbShvng-LS, AVVG, AVBbShv, AVVng-LS, AVBbShvng-LS
insulated: PVC insulated
construction: copper or aluminum conductor PVC insulated PVC jacket power cable
application: underground power cable
Conductor Material: copper or aluminum
packing: wooden drum or upon clients demand
delivery: 15days and also depend on the quantity
Conductor Type: Stranded
color: Black or as your request
Delivery Detail: Shipped in 15 days after payment
Packaging Detail: VVG,VBbShv,VVng-LS,VBbShvng-LS, AVVG, AVBbShv, AVVng-LS, AVBbShvng-LS packing in wooden drum, steel wooden drum or according to your requirement

VVG,VBbShv,VVng-LS,VBbShvng-LS, AVVG, AVBbShv, AVVng-LS, AVBbShvng-LS

PVC insulated Copper Aluminum conductor power cables rated for 660 and 1000 V(LS in the name of cable means Low Smoke)

Equivalent

VVG – NYY-J, NYY-O;
VBbShv – Cu/PVC/STA /PVC;
VBbShvng-LS – Cu/LSON /STA /LSON ,
AVVG – NA YY-J, NA YY-O;
AVBbShv – AI /PVC/STA /PVC;
AVBbShvng-LS – AI /LSOH /STA /LSOH

 

 

 

Construction:

1. Conductor -copper (VBbShvng-LS) or aluminum (AVBbShvng -LS), solid or multiwire, round- or sectorshaped,

class 1 or 2 as per IEC 60228 in accordance with the table below:

 

Conductor designation

Nominal area of conductors, mm2

Round-shaped

Sector-shaped

Copper

aluminum

Copper

aluminum

 Solid

1.5-25

2.5-35

Multiwire

16-50

50

50-240

70-240

 

2. Insulation – PVC for AVVG, VVG, AVBbShv and VBbShv, Flameretardant PVC for AVVng-LS, VVng-LS, AVBbShvng-LS and VBbShvng-LS.

Insulated multiconductor cable conductors carry identification coloring. Neutral conductor insulation is blue. Grounding conductor insulation (PE, PEN) is in two colors (yellow-green). The identification coloring of the other conductors is either solid or in form of longitudinal stripes of at least 1 mm.

3. Twisting – Insulated conductors are twisted. Cables are of five conductors. Round-shaped conductors are twisted around a mandrel made of the sheathing PVC. Sector-shaped conductor cables have polypropilene binding tape applied around twisted conductors. Also allowed is the application of a central sheathing or insulation material filler in between the conductors.

 

For VVG, AVVG, AVVng-LS and VVng-LS cables

For VBbShv, AVBbShv, AVBbShvng-LS and VBbShvng-LS cables

4. Filling – for round-shaped core cables such as VVG and AVVG,  it is extruded from calcium carbonate filled rubber compound or similar material  to form a round section. For AVVng-LS and VVng-LS cables it is extruded from flameretardant PVC or flameretardant crude rubber 0.5 mm thick (reference value). Sector-shaped core cables come without filling.

5. Jacket – PVC applied over the filling or binder for VVG and AVVG cables and flameretardant PVC for AVVng-LS and VVng-LS cables

4. Girth insulation – PVC applied over twisted round-shaped insulated cores or binding tape at least 0.9 mm thick for VBbShv, AVBbShv cables and flameretardant PVC for AVBbShvng-LS and VBbShvng-LS cables

5. Protecting armoring

two galvinized steel armor tapes 0.3 mm or 0.5 mm thick respectively whereas the upper tape cover the gaps in between the turns of the lower one

Protective jacket for VBbShv, AVBbShv cables is from PVC and AVBbShvng-LS and VBbShvng-LS cables is from flameretardant PVC.

 

Application:

The cables are intended for transmitting and distributing electric power in fixed installations rated for nominal alternating current voltages of 0.66 KV and 1 KV  with frequencies of up to 100 Hz.

VVG and AVVG cables are meant for laying inside both dry and wet industrial premises on special trestles, in assemblies as well as for laying outdoors. Cables are not recommended for burying in trenches. Cables are flameretardant if laid singly.

 

VBbShv and AVBbShv cables are meant for burying (in trenches), in premises, tunnels, ducts, mines (except for laying in assemblies) as well as for laying outdoors if the cable is not exposed to considerable stretching effects, however, in presense of danger of mechanical damage during the operation. Cables are flameretardant if laid singly.

Flameretardant and low smoke VVng-LS, AVVng-LS, VBbShvng-LS and AVBbShvng-LS cables are meant for industrial and nuclear power plant applications when supplied to the domestic market and abroad. Cables are intended fo be operated in cable works and premises as well as for the applications in nuclear power plant units class 2, 3 and 4 as per classification OPB-88/97 (PNAE G-01-011-97). Cables are flameretardant if laid in bunches.

 

 

Technical details:

Type of climatization of cables is UHL and T, allocation category is 1 and 5 as per GOST 15150-69.

Operating temperature range ………………………………………………………………….-50°V to +50°V

Relative humidity of air at temperatures of up to 35 oC………………………………..up to 98%

Cables shall be laid and installed without preheating at temperatures not lower than …-15 0C

Minimum bending radius when laid:…………………………………………..7.5 outer diameters

Rated frequency…………………………………………………………………..50 Hz

 

AC testing voltage 50 Hz……………………………………………………………………… 3.5KV

 

Continuously permissible conductor operating heating temperature……..………………+70 0C

 

permissible conductor short-circuit temperature is maximum + 160 °C.

 

short-circuit duration shall not exceed 4 s.

 

Permissible cable emergency mode heating, not greater than:…………………………………..+80 0C

 

cable operation duration in emergency operation shall not last more than 8 hours a day and not more than 1000 h throughout their lifetime.

 

Smoke emissions in burning or smoldering of cables shall not result in decrease in light penetration in testing chamber by more than 40%.

 

Construction lengths for main conductor areas:

 

to 16 mm2……………………………………………………………………………………450 m

 

25 to 70 mm2 …………………………………………………………………………………….300 m

 

95 mm2 or greater……………………………………………………………………………….200 m

 

Guarantee service life…………………………………….5 years from putting into operation but not later than 6 months from the manufacture

 

Service life………………………………………………..  30 years

 

OKP codes:

 

35 3371 27 – VVG cables
35 3771 53 – AVVG cables
35 3371 31 – VBbShv cables 
35 3771 57 – AVBbShv cables
35 3371 35 – VVGng-LS cables
35 3371 72 – AVVGng-LS cables
35 3771 74 – AVBbShvng-LS cables
35 7771 38 – VBbShvng-LS cables 
35 3371 35 – VVG cables

 

 

 

 

Tags: , ,