NFC34-125 BS AAC ACSR AAAC overhead line bare Conductor

NFC34-125 BS AAC ACSR AAAC overhead line bare Conductor
Port: Qingdao
Payment Terms: L/C,T/T,Western Union
Supply Ability: 150 Kilometer/Kilometers per Month
Place of Origin: Henan China
Brand Name: Hongda
Model Number: AAAC
Insulation Material: Bare
Application: Overhead
Conductor Material: Aluminum
Jacket: Bare
Standard: BS IEC ASTM DIN
Delivery Detail: Shipped in 10 days after payment
Packaging Detail: Wooden Drum
Product Description
NFC34-125 BS AAC ACSR AAAC overhead line bare Conductor
 
 

AAAC (All Aluminum Alloy Conductor) referred to have higher strength but lower conductivity than pure aluminum. Being lighter, alloy conductors can sometimes be used to advantage in place of the more conventional ACSR;

 

Having lower breaking loads than the latter, their use becomes particularly favourable when ice and win loadings are low. 
We can supply this conductor according to different recognized standards, such as BS EN50182, IEC61089, ASTM B399DIN 48, customer special specification also can be satisfied. 
 

 Applications:

Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum-alloy to achieve a high strength-to-weight ratio; affords good sag characteristics. Aluminum-alloy gives 6201-T81 gives AAAC higher resistance to corrosion than ACSR.

 

 

                                            ALUMINIUM ALLOY CONDUCTOR                    ASTM B399
Code Name Area Size&Stranding of ACSR with equal diameter No. and diameter  Overall diameter Weight Nominal breaking load MAX .DC resistance at 20℃
Nominal Actual AWG or MCM Al/St
  MCM mm2     mm mm kg/km kN ohm/km
AKRON 30.58 15.48 6 6/1 7/1.68 5.04 42.7 4.92 0.3966
ALTON 48.69 24.71 4 6/1 7/2.12 6.35 68 7.84 0.3811
AMES 77.47 39.22 2 6/1 7/2.67 8.02 108 12.45 0.3671
AZUSA 123.3 62.38 1/0 6/1 7/3.37 10.11 172 18.97 0.3524
ANAHEIM 155.4 78.65 2/0 6/1 7/3.78 11.35 217 23.93 0.3448
AMHERST 195.7 99.22 3/0 6/1 7/4.25 12.75 273 30.18 0.3375
ALLIANCE 246.9 125.1 4/0 6/1 7/4.77 14.31 345 38.05 0.3306
BUTTE 312.8 158.6 266.8 26/7 19/3.26 16.3 437 48.76 0.3196
CANTON 394.5 199.9 366.4 26/7 19/3.66 18.3 551 58.91 0.3124
CAIRO 465.4 235.8 397.5 26/7 19/3.98 19.88 650 69.48 0.3071
DARIEN 559.5 283.5 477 26/7 19/4.36 21.79 781 83.52 0.3014
ELGIN 652.4 330.6 556.5 26/7 19/4.71 23.54 911 97.42 0.2966
FLINT 740.8 375.3 636 26/7 37/3.59 25.16 1035 108.21 0.2917
GREELY 927.2 469.8 795 26/7 37/4.02 28.14 1295 135.47 0.2846

 

 

 

                                      ALUMINIUM ALLOY CONDUCTOR             BSEN50183
Code Name Calculated Area No. Of Wires Diameter Weight Rated Strength MAX .DC resistance at 20
Wire Cond.
  mm2   mm mm kg/km Kn ohm/km
Box 18.8 7 1.85 5.55 51.4 5.55 1.748
Acacia 23.8 7 2.08 6.24 64.9 7.02 1.3828
Almond 30.1 7 2.34 7.02 82.2 8.88 1.0926
Cedar 35.5 7 2.54 7.62 96.8 10.46 0.9273
Deodar 42.2 7 2.77 8.31 115.2 12.44 0.7797
Fir 47.8 7 2.95 8.85 130.6 14.11 0.6875
Hazel 59.9 7 3.3 9.9 163.4 17.66 0.5494
Pine 71.6 7 3.61 10.8 195.6 21.14 0.4591
Holly 84.1 7 3.91 11.7 229.5 24.79 0.3913
Willow 89.7 7 4.04 12.1 245 26.47 0.3665
Oak 118.9 7 4.65 14 324.5 35.07 0.2767
Mulberry 150.9 19 3.18 15.9 414.3 44.52 0.2192
Ash 180.7 19 3.48 17.4 496.1 53.31 0.183
Elm 211 19 3.76 18.8 579.2 62.24 0.1568
Poplar 239.4 37 2.87 20.1 659.4 70.61 0.1387
Sycamore 303.2 37 3.23 22.6 835.2 89.4 0.1095
Upas 362.1 37 3.53 24.7 997.5 106.82 0.0917
Yew 479 37 4.06 28.4 1319.6 141.31 0.0693
Totara 498.1 37 4.14 29 1372.1 146.93 0.0666
Rubus 586.9 61 3.5 31.5 1622 173.13 0.0567
Sorbus 659.4 61 3.71 33.4 1822.5 194.53 0.0505
Araucaria 821.1 61 4.14 37.3 2269.4 242.24 0.0406
Redwood 996.2 61 4.56 41 2753.2 293.88 0.0334

 

 

ALUMINIUM ALLOY CONDUCTOR                 BS 3242
Code Name Calculated Area No. Of Wires Diameter Weight Rated Strength MAX .DC resistance at 20
Wire Cond.
  mm2   mm mm kg/km Kn ohm/km
Box 15 7/1.85 18.82 5.55 51 537 1.7495
Acacia 20 7/2.08 23.79 6.24 65 680 1.384
Almond 25 7/2.34 30.1 7.02 82 861 1.0934
Cedar 30 7/2.54 35.47 7.62 97 1014 0.9281
35 7/2.77 42.18 8.31 115 1205 0.7804
Fir 40 7/2.95 47.87 8.85 131 1367 0.688
Hazel 50 7/3.30 59.87 9.9 164 1711 0.5498
Pine 60 7/3.61 71.65 10.83 196 2048 0.4594
70 7/3.91 84.05 11.73 230 2402 0.3917
Willow 75 7/4.04 89.73 12.12 245 2565 0.3669
80 7/4.19 96.52 12.57 264 2758 0.3441
90 7/4.44 108 13.32 298 3112 0.3023
Oak 100 7/4.65 118.9 13.95 325 3398 0.2769
100 19/2.82 118.7 14.1 326 3393 0.2787
Mulbery 125 19/3.18 150.9 15.9 415 4312 0.2192
Ash 150 19/3.48 180.7 17.4 497 5164 0.1831
Elm 175 19/3.76 211 18.8 580 6030 0.1568
Poplar 200 37/2.87 239.4 20.09 659 8841 0.1385
225 37/3.05 270.3 21.35 744 7724 0.1227
Sycamore 250 37/3.22 303.2 22.54 835 8664 0.1093
Upas 300 37/3.53 362.1 24.71 997 10350 0.09156
Walnut 350 37/3.81 421.8 26.67 1162 12053 0.0786
Yew 400 37/4.06 479 28.42 1319 13685 0.06921
Totara 425 37/4.14 498.1 28.98 1372 14233 0.06656
Rubus 500 61/3.50 586.9 31.5 1620 16771 0.05662
Araucaria 700 61/4.14 821.1 37.26 2266 23450 0.04047

 

 

aluminum conductor

 

 Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204.

 All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM

 (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228

(AAAC) Conductor as per ASTM-B-399-1992

(AAAC) Conductor as per BS-3242-1970

(AAAC) Conductor IS: 398-IV-1994

(ACSR) as per ASTM-B-233-1992  aluminum conductor

(AAC) as per BS-215-1-1970

(AAC) as per IS-398-1: 1976

(AAC) as per ASTM-B-231-1990

(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992

(ACSR) BS-215-II-1970

(AACSR) as per IEC-1089-1191

AAC(All aluminum conductor) are suited for overhead power line.  aluminum conductor

We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.

Applications:

Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

aluminum conduc 

Packaging & shipping

china cable supplier

Packaging Detail: export wooden drum pack bare acsr conductor, wooden iron drum and other export standard package
Delivery Detail: 10 days and also depend on the quantity

 

 

Company Information

 

 

 

 

 

Q: Are you trading company or manufacturer ?

A: We are factory.

Q: How long is your delivery time?

A: Generally it is 5-10 days if the goods are in stock. or it is 15-20 days if the goods are not in stock, it is according to quantity.

Q: Do you provide samples ? is it free or extra ?

A: Yes, we could offer the sample for free charge but do not pay the cost of freight.

Q: What is your terms of payment ?

A: 30% T/T in advance,70% T/T balance before shipment

Tags: , ,