copper cable 1.5 mm 2.5mm 4mm 6mm 10mm house wiring Electrical cable copper single core PVC wire

copper cable 1.5 mm 2.5mm 4mm 6mm 10mm house wiring Electrical cable copper single core PVC wire
Port: Qingdao
Payment Terms: L/C,D/P,T/T,Western Union,MoneyGram
Supply Ability: 2000 Kilometer/Kilometers per Month fire resistance building wire
Place of Origin: Henan China
Brand Name: Hongda
Model Number: housing wire
Insulation Material: PVC
Type: Low Voltage
Application: Construction
Conductor Material: Copper
Jacket: PVC
Conductor: Solid Copper
Certificate: ISO9001,CCC
Rated voltage: 300/300V,300/500V,450/750 V fire resistance building wire
Insulation: PVC
housing wire Packing: in coils
Standard: 60227 IEC 01 (Cu/PVC)
Application: Construction, house wiring electrical wire for construction&building
Company nature: Manufactory
Cable Color: Red, yellow, blue, green, black, white, or as required
Conductor Type: Strand or solid
Packaging Detail: We packed house wiring electrical wire by roll/drum, 100m/roll or as your request for Copper wire for house wiring.

copper cable 1.5 mm 2.5mm 4mm 6mm 10mm house wiring Electrical cable copper single core PVC wire

Product Description

 

Hongda Cable single core electrical wiring fire resistance house building wire

Fire and Safety Cables

The areas for Fire resistant cable applications include places where large number of people congregate for short or limited period of time such as shopping malls, cinema theatres, educational institutions, airport terminals, mass transit systems (metro rail networks), high rise office buildings etc. FR cables also find use in power generation facilities, petrochemical complexes, nuclear power facilities, mines etc. for phased shut down of the plant and to keep critical functions like communication, rescue and evacuation systems functional during a fire.

  • Construction: Single Core / Pair / Triad and Multi Cores / Pairs / Traids
  • Voltage Grade : 600/1100 VAC
  • Conductor : Stranded or solid annealed bare or Tinned Copper Conductor
  • Fire Barrier : Glass mica tape
  • Insulation : Silicone rubber or Cross linked. Poly-olefin elastomer, Individual and/or overall with following options, PVC insulated.
  • Screening : Aluminum Mylar/Copper Tape with Tinned Copper Drain Wire or, Braided with Bare or Tinned or Nickel Plated or Silver Plated Copper, Inner Sheath-LSOH / ZHFR or equivalent.
  • Armouring : Galvanised Steel wire helical armouring /GI strip or wire braiding
  • Outer Sheath : LSOH / ZHFR or equivalent
  • Standards : BS : 5308 or equivalent with fire resistance to BS:6387 category CWZ and. IEC : 60331 tested for 950°C for 3 hrs.

 

Standard for fire resistance house building wire

GB 5023.11997 , JB 8734.15-1998, Q/ZEL 02-2002, GB 5023.17-1997,  IEC227

 

For separate earth conductors.

For switchboard and control panel wiring.

For fixed wiring within other enclosures or apparatus where the cable is not accessible without the use of tools.

STANDARD

IEC60227-3:1997

AS/NZS 5000.1

CODEDESIGNATION

60227 IEC 01 (BV, Cu/PVC)

 

VOLTAGE

450/750V

600/1000V

CONDUCTOR

Copper 1.5 – 185mm2

Copper 1 – 240mm2

INSULATION

PVC/C
See below for colour options

PVC, V-90
See below for colour options

MAX. OPERATING TEMP.

70°C

90°C

 

Technical Parameter of electrical wiring electrical cable

CONDUCTOR

CURRENT RATING (a)

ELECTRICAL CHARACTERISTICS

Nominal

Area

mm2

FIXED WIRING

Maximum DC

Resistance

@20℃

Ω/km

Maximum AC

Resistance

@90℃

Ω/km

Equivalent

Star Reactance

(trefoil)

Ω/km

Single Phase

Voltage Drop

(trefoil) @90℃

mV/Am

Unenclosed

In Air

 

Conduit

In Air

 

1.5

16

16

13.6

17.3

0.157

34.7

2.5

23

24

7.41

9.45

0.143

18.9

4

31

32

4.61

5.88

0.137

11.8

6

40

41

3.08

3.93

0.128

7.87

10

54

54

1.83

2.33

0.118

4.68

16

72

70

1.15

1.47

0.111

2.95

25

97

94

0.727

0.927

0.106

1.87

35

119

112

0.524

0.668

0.101

1.35

50

146

138

0.387

0.494

0.0962

1.01

70

184

170

0.268

0.342

0.0917

0.710

95

230

212

0.193

0.247

0.0904

0.528

120

267

242

0.153

0.197

0.0870

0.431

150

308

282

0.124

0.160

0.0868

0.365

185

358

320

0.0991

0.129

0.0862

0.329

240

428

361

0.0754

0.0991

0.0847

0.283

 

Based on 40℃ ambient air temperature.

The above information is from the following sources:

•   IEC 60287  Electric cables – Calculation of the current rating (all Parts)

•   IEC 60364  Electrical installations of buildings

•   IEC 60228  Conductors of insulated cables

 

 

Our Services

 

Electric Cable Markings

All 2.5mm electric cable will carry the following items on the surface print:

Manufacturers Name
Electric Cable
Voltage Designation
British Standard Number
Cross Sectional Area
No. of Cores
Type of Cable
Date
NOTE: Items 1 to 4 will also be embossed on the Oversheath of the cable

Some special cable marking accept customized.

Electric Cable Application:

Packaging & Shipping

 

Packing :  We packed it by roll, 100m/roll.or as your request for 2.5mm electric cable

Shipping : Within 7 working days or as to the buyers' request.

Company Information

 

Company & Certification:

 

 

FAQ

Q: Are you trading company or manufacturer ?

A: We are factory.

Q: How long is your delivery time?

A: Generally it is 5-10 days if the goods are in stock. or it is 15-20 days if the goods are not in stock, it is according to quantity.

Q: Do you provide samples ? is it free or extra ?

A: Yes, we could offer the sample for free charge but do not pay the cost of freight.

Q: What is your terms of payment ?

A: Payment<=1000USD, 100% in advance. Payment>=1000USD, 30% T/T in advance ,balance before shipment.
If you have another question, pls feel free to contact us as below:

Contact Information

 

If you can't find the product you need in the list, please contact me, and I will serve for you wholeheartedly !!!

Vivian Yuan | Sales Director

Tags: , ,

Contact us

 

 

 

Search