XLPE insulated underground Electrical Cable Specifications 50mm2 95mm2 120mm2 150mm2 185mm2

XLPE insulated underground Electrical Cable Specifications 50mm2 95mm2 120mm2 150mm2 185mm2
Port: Tianjin
Payment Terms: L/C,T/T,Western Union
Supply Ability: 5000 Kilometer/Kilometers per Month
Place of Origin: Hebei China
Brand Name: HAOHUA
Model Number: YJV,VV
Insulation Material: XLPE
Type: LV & MV
Application: Underground
Conductor Material: Copper
Jacket: PVC
Standard: IEC 60502, BS 6622, GB/T12706
Certificate: CCC,CE, ISO9001
Packing: Wooden drum or as per requirement
Company nature: Manufactury
Delivery Detail: Shipped in 20 days after payment
Packaging Detail: Eltrical cable should be supplied in steel drum, wooden drum or as per requirement. Cable piece length should be of 500 meter length or as specified by the customer at the time of order.

    XLPE insulated underground Electrical Cable Specifications  50mm2 95mm2 120mm2 150mm2 185mm2

Product Description

Description

Conductor: Solid or stranded copper 
Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC) 
Filler: Polypropylene filament with lapped binding tape 
Binder: Binding tape
Inner sheath: Polyvinyl chloride (PVC) 
Amour: Galvanized steel wire armored(SWA) or steel tape armored(STA) 
Sheath: Polyvinyl chloride (PVC) 

 

Operating Characteristic:

Max: short-circuit temperature of conductor shall not exceed 250°C(5s maximum duration):

Cross section of conductor≤300mm2 160°C

Cross section of conductor>300mm2   140°C

The ambient temperature under installation of cable should not below 0°C

The bending radius of cable should not less than 10 times of diameter of the cable.

 

In Air

1, The single-core cables are paralleled laid, the distance between the cable center is 2 times diameter of the cable for cross section of conductor ≤185mm2 and 90mm for cross section of conductor≥240 mm2

2, Ambient air temperature: 40°C 

 3,Max.Permissible continuous operating temperature of conductor: 70°C

 

In ground

1, when the single-core cables are installed separately, the distance between the cable’s centers is 2 times diameter of the cable.

2, Solid temperature: 25°C

3, Max. Permissible continuous operating temperature of conductor: 70°C

4,Solid thermal resistivity: 10°Cm/w

5,Depth of laying: 0.7m

 

 

Type ,application

Type

Description

Main Application

Cu core

Al core

YJV

or

YJY

YJLV

or

YJLY

Cu,Al core XLPE insulated, PVC or PE sheathed power cable

For laying indoor, tunnel, underground and canal.Unable to bear external mechanical pulling force and pressure during laid.

YJV22

or

YJV23

YJLV22

or

YJLV23

Cu,Al core XLPE insulated,Steel tape armoured, PVC or PE sheathed power cable

For laying indoor, tunnel, underground and canal. Able to bear external mechanical pressure, but unable to bear large pulling force

YJV32

or

YJV33

YJLV32

or

YJLV33

Cu,Al core XLPE insulated, fine steel wire armoured, PVC or PE sheathed power cable

For laying in silo, underwater and large difference of level, able to bear external mechanical pressure and moderate pulling force.

YJV42

or

YJV43

YJLV42

or

YJLV43

Cu,Al core XLPE insulated, thick steel wire armoured, PVC or PE sheathed power cable

For laying in water, seabed and large difference of level, able to bear larger mechanical pressure and pulling force

 

Specification for electrical cable

Type

Description

Number of cores

Nominal cross section of conductor (mm2)

3.6/6kV

6/10kV 6.35/11kV

8.7/15kV

12/20kV 12.7/22kV

18/30kV 19/33kV 25/36kV

YJV

CU/XLPE/PVC

1, 3

10~1000

16~1000

25~1000

35~1000

50~1000

YJLV

AL/XLPE/PVC

YJSV

CU/XLPE/CWS/PVC

1, 3

10~1000

16~1000

25~1000

35~1000

50~1000

YJLSV

AL/XLPE/CWS/PVC

YJY

CU/XLPE/PE

1, 3

10~1000

16~1000

25~1000

35~1000

50~1000

YJLY

AL/XLPE/PE

Z-YJV

CU/XLPE Flame-retardant

1, 3

10~1000

16~1000

25~1000

35~1000

50~1000

Z-YJLV

AL/XLPE Flame-retardant

WDZ-YJY

CU/XLPE/LSHF(or LSZH) Flame-retardant

1, 3

10~1000

16~1000

25~1000

35~1000

50~1000

WDZ-YJLY

AL/XLPE/LSHF (or LSZH) Flame-retardant

N-YJV

CU/XLPE Fire-resistant

1, 3

10~1000

16~1000

25~1000

35~1000

50~1000

 

 

Company Information

 Production Facility

Inspection Equipment

 

 

 

 

Packaging & Shipping

The cable will be packed with  steel wooden drum (fumigation), and the cable length in each drum is 500m/1000m or as per actual cable length requirements.

 

 

About the supplier

Send  Your Inquiry Details in the Below for Free Sample, Click "Send" now!

 

 

 

Tags: , ,

Contact us

 

 

 

Search