ABC CABLE:
1. The conductor is made of compact circular aluminum strands conductors, the insulation is by Black extruded Cross-linked polyethylene.
2. The cable is twisted by two or more equal sized insulated conductors, and the tensile load is evenly distributed between several conductors.
3. The conductor is fully in line with the management standard, and we have carried out all tests on the cable and have relevant test reports.
4. We have passed ISO 9001 quality certification.
ABC cables are mainly used for overhead applications of 0.6/1KV, such as street lighting, outdoor lighting and temporary buildings. ABC cables have more advantages compared with bare wires, such as short laying span, high safety and reliability, good atmospheric anti-aging performance and so on. ABC cables are also commonly used in Urban and rural transmission construction projects.
|
Nom.Cross section(mm²) |
Insulation Thickness (mm) |
Outer Diameter Approx.(mm) |
Conductor Resistance at 20 ℃(Ω/KM) |
Breaking Load(N) |
Permissible Ampacity at 25℃ (In Air) (A) |
|
10 |
1 |
6 |
≤3.08 |
≥1650 |
65 |
|
16 |
1.2 |
7.4 |
≤1.91 |
≥2517 |
86 |
|
25 |
1.2 |
8.5 |
≤1.20 |
≥3762 |
111 |
|
35 |
1.4 |
9.8 |
≤0.868 |
≥5177 |
128 |
|
50 |
1.4 |
11.1 |
≤0.641 |
≥7011 |
154 |
|
70 |
1.4 |
12.8 |
≤0.443 |
≥10354 |
193 |
|
95 |
1.6 |
14.8 |
≤0.320 |
≥13727 |
236 |
|
120 |
1.6 |
16.2 |
≤0.253 |
≥17339 |
274 |
|
150 |
1.8 |
17.8 |
≤0.206 |
≥21033 |
316 |
|
185 |
2 |
20.2 |
≤0.164 |
≥26732 |
355 |
|
240 |
2.2 |
22.8 |
≤0.125 |
≥34679 |
419 |
|
SPEC mm2 |
Conductor structure |
Insulation Material |
Insulation Thickness (mm) |
Approx overall diameter (mm) |
Approx weight (kg/km) |
|
|
Phase (compacted Al) |
Neutral (alloy) |
|||||
|
No./mm |
No./mm |
|||||
|
1*16+1*16 |
7/1.72 |
7/1.72 |
XLPE
(HDPE)
PVC |
1.2 |
12.5 |
110.1 |
|
1*25+1*25 |
7/2.15 |
7/2.15 |
1.2 |
14.9 |
163.9 |
|
|
1*35+1*35 |
7/2.54 |
7/2.54 |
1.4 |
17.5 |
229.0 |
|
|
1*50+1*50 |
7/2.92 |
7/2.92 |
1.4 |
20.1 |
300.0 |
|
|
1*70+1*70 |
19/2.15 |
19/2.15 |
1.4 |
23.6 |
423.2 |
|
|
1*95+1*95 |
19/2.54 |
19/2.54 |
1.6 |
27.6 |
585.4 |
|
|
2*16+1*16 |
7/1.72 |
7/1.72 |
1.2 |
14.2 |
175.8 |
|
|
2*25+1*25 |
7/2.15 |
7/2.15 |
1.2 |
16.7 |
258.4 |
|
|
2*35+1*35 |
7/2.54 |
7/2.54 |
1.4 |
19.7 |
361.2 |
|
|
2*50+1*50 |
7/2.92 |
7/2.92 |
1.4 |
22.5 |
472.1 |
|
|
2*70+1*70 |
19/2.15 |
19/2.15 |
1.4 |
26.1 |
658.3 |
|
|
2*95+1*95 |
19/2.54 |
19/2.54 |
1.6 |
30.5 |
908.2 |
|
|
3*16+1*16 |
7/1.72 |
7/1.72 |
1.2 |
16.3 |
241.5 |
|
|
3*25+1*25 |
7/2.15 |
7/2.15 |
1.2 |
19.1 |
353.6 |
|
|
3*35+1*35 |
7/2.54 |
7/2.54 |
1.4 |
22.5 |
493.5 |
|
|
3*50+1*50 |
7/2.92 |
7/2.92 |
1.4 |
25.7 |
644.1 |
|
|
3*70+1*70 |
19/2.15 |
19/2.15 |
1.4 |
29.7 |
895.2 |
|
|
3*95+1*95 |
19/2.54 |
19/2.54 |
1.6 |
34.6 |
1233.5 |
|
The aim of the package is ensure the product send to the destinations safely . If you have no mind about the package ,we will give you a most economic way .
Always we make it in drum for cable ,in coil for wire
| ABC cable | electrical wire | power cable |
| armored power cable | Concentric cable | control cable |