electrical cable size Copper Conductor XLPE/EPR Insulated Aluminium Wire Armoured

Port: | Qing Dao |
Payment Terms: | L/C,T/T,Western Union,face to face |
Supply Ability: | 50000 Meter/Meters per Day electrical cable size |
Place of Origin: | Henan China |
Brand Name: | Zi Wang |
Model Number: | YJV,YJV22,YJV33 |
Insulation Material: | XLPE/EPR |
Type: | Medium Voltage |
Application: | Underground |
Conductor Material: | Copper |
Jacket: | PVC |
product name: | electrical cable size |
company name: | Henan Central Plain Cables And Wires Co., Ltd. |
color: | black or according to your need |
Certification: | ISO, CCC, CE, RoHS, UL, VDE |
Material Shape: | Round Wire |
Markets: | Global |
Cross-sectional area: | 1.5MM~800MM |
standard: | IEC, BS, ASTM, DIN, CSA |
cores: | 1.2.3.4.... |
Rated voltage U0/U: | 0.6/1kv 8.7/12kv 35kv 110kv or over |
Packaging Detail: | Wood Drum or according to your need for electrical cable size |
electrical cable size
electrical cable size Copper Conductor XLPE/EPR Insulated Aluminium Wire Armoured
Product Description of electrical cable size
Single Core Cables to BS 6622/BS7835
APPLICATIONS
The single core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.8/6.6KV to 19/33KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.
STANDARD:
BS 6622
BS 7835 (LSZH)
CONSTRUCTION:
Conductor:Plain annealed copper or aluminium complying with IEC 60228/BS 6360. Copper conductors shall be stranded (class 2) and aluminium conductors shall be either solid or stranded (class 2).
Conductor Screen: Extruded layer of semi-conducting cross-linkable compound is applied over the conductor and shall cover the surface completely. The minimum thickness is 0.3mm and the maximum resistivity shall not exceed 500 Ohm-m at 90°C.
Insulation: Insulation is of cross-linked polyethylene compound XLPE (GP8) conforming to BS 7655-1.3 or EPR (GP7), conforming to BS 7655-1.2.
Table 1. Insulation Thickness
Insulaton Screen: Extruded layer of semi-conducting cross-linkable compound is applied over the insulation. The extruded semi-conducting layer shall consist of bonded or cold strippable semi conducting compound capable of removal for jointing or terminating. As an option, a semi conducting tape may be applied over the extruded semi conducting layer as a bedding for the metallic layer. The minimum thickness is 0.3 mm and the maximum resistivity is 500 Ohm-m at 90°C. The screen is tightly fitted to the insulation to exclude all air voids and can be easily hand stripped on site.
Metallic Layer: The metallic layer shall consist of either copper tapes or a concentric layer of copper wires or a combination of tapes and wires. The metallic layer provides an earth fault current path, capable of withstanding fault current to earth of 1000A for one second at maximum temperature 160°C. Copper wires are applied over the conducting water blocking layer with a minimum diameter of 0.5mm. And over the copper wires, copper tape with minimum thickness of 0.1mm can be applied helically with overlap. Total cross section of copper wire screen layer is shown in table 2.
Table 2. Minimum Total Cross Section of Copper Wire Screen & DC Resistance of the screen
Separation Sheath (for armoured cable): The separation sheath comprises a layer of extruded PVC, PE or LSZH. The nominal thickness is calculated by 0.02Du + 0.6mm where Du is the fictitious diameter under the sheath in mm. The nominal separation sheath thickness shall not be less than 1.2mm.
Armour (for armoured cable): The armour consists of round aluminium wire with diameter specified as in Table 3.
Table 3. Armour Wire Diameter
Over Sheath: Overall sheath comprises a layer of extruded either PVC type 9 conforming to BS 7665-4.2 or MDPE type TS2 conforming to BS 7655-10.1. LSZH can be offered as an option. The oversheath is normally black in colour. When a DC voltage test is to be performed on the oversheath, a semi conducting layer such as graphite coating shall be applied over the surface of the extruded oversheath. The nominal oversheath thickness is calculated by 0.035+D where D is the diameter immediately under the oversheath in mm. For cables with the oversheath not applied over the armour, the nominal oversheath thickness shall not be less than 1.4mm. And for cables with oversheath applied over the armour, the nominal oversheath thickness shall not be less than 1.8mm.
PHYSICAL PROPERTIES:
Operating Temperature: up to 90°C
Temperature Range: -5°C ( PVC sheath ); -20°C ( PE sheath )
Short Circuit Temperature: 250°C (short circuit duration up to 5 seconds)
Bending Radius: 12 x OD
Table 4. Nominal /Operating /Test Voltages:
Factory Show:
Package And Transportation:
We are specializing in the production of cables and wires,the spirt of us is "quality first, reputation first, service first, customer first"
- Next: Low voltage Cu/XLPE/PVC 120mm2 Power Cable
- Previous: low voltage armored cable/tower crane power cable/standard size price power cable
Contact us
Search
You May Like
-
PVC/XLPE Insulated Multi core Electrical cable Size 16mm2 25mm2 50mm2 70mm2 95mm2 120mm2
-
China good price 35mm2 50mm2 70mm2 95mm2 120mm2 185mm2 electrical cable size
-
PVC insulation cable fine structure standard electrical cable size
-
electrical cable price list in malaysia electrical cable size electrical power cable types