electrical cable size Copper Conductor XLPE/EPR Insulated Aluminium Wire Armoured

electrical cable size Copper Conductor XLPE/EPR Insulated Aluminium Wire Armoured
Port: Qing Dao
Payment Terms: L/C,T/T,Western Union,face to face
Supply Ability: 50000 Meter/Meters per Day electrical cable size
Place of Origin: Henan China
Brand Name: Zi Wang
Model Number: YJV,YJV22,YJV33
Insulation Material: XLPE/EPR
Type: Medium Voltage
Application: Underground
Conductor Material: Copper
Jacket: PVC
product name: electrical cable size
company name: Henan Central Plain Cables And Wires Co., Ltd.
color: black or according to your need
Certification: ISO, CCC, CE, RoHS, UL, VDE
Material Shape: Round Wire
Markets: Global
Cross-sectional area: 1.5MM~800MM
standard: IEC, BS, ASTM, DIN, CSA
cores: 1.2.3.4....
Rated voltage U0/U: 0.6/1kv 8.7/12kv 35kv 110kv or over
Packaging Detail: Wood Drum or according to your need for electrical cable size

electrical cable size

electrical cable size Copper Conductor XLPE/EPR Insulated Aluminium Wire Armoured

Product Description of electrical cable size

Single Core Cables to BS 6622/BS7835

APPLICATIONS

The single core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.8/6.6KV to 19/33KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations. 

STANDARD:

BS 6622 
BS 7835 (LSZH)

CONSTRUCTION:

Conductor:Plain annealed copper or aluminium complying with IEC 60228/BS 6360. Copper conductors shall be stranded (class 2) and aluminium conductors shall be either solid or stranded (class 2).

Conductor Screen: Extruded layer of semi-conducting cross-linkable compound is applied over the conductor and shall cover the surface completely. The minimum thickness is 0.3mm and the maximum resistivity shall not exceed 500 Ohm-m at 90°C.
Insulation: Insulation is of cross-linked polyethylene compound XLPE (GP8) conforming to BS 7655-1.3 or EPR (GP7), conforming to BS 7655-1.2.

Table 1. Insulation Thickness

  Insulaton Screen: Extruded layer of semi-conducting cross-linkable compound is applied over the insulation. The extruded semi-conducting layer shall consist of bonded or cold strippable semi conducting compound capable of removal for jointing or terminating. As an option, a semi conducting tape may be applied over the extruded semi conducting layer as a bedding for the metallic layer. The minimum thickness is 0.3 mm and the maximum resistivity is 500 Ohm-m at 90°C. The screen is tightly fitted to the insulation to exclude all air voids and can be easily hand stripped on site. 
Metallic Layer: The metallic layer shall consist of either copper tapes or a concentric layer of copper wires or a combination of tapes and wires. The metallic layer provides an earth fault current path, capable of withstanding fault current to earth of 1000A for one second at maximum temperature 160°C. Copper wires are applied over the conducting water blocking layer with a minimum diameter of 0.5mm. And over the copper wires, copper tape with minimum thickness of 0.1mm can be applied helically with overlap. Total cross section of copper wire screen layer is shown in table 2.

Table 2. Minimum Total Cross Section of Copper Wire Screen & DC Resistance of the screen

Separation Sheath (for armoured cable): The separation sheath comprises a layer of extruded PVC, PE or LSZH. The nominal thickness is calculated by 0.02Du + 0.6mm where Du is the fictitious diameter under the sheath in mm. The nominal separation sheath thickness shall not be less than 1.2mm.
Armour (for armoured cable): The armour consists of round aluminium wire with diameter specified as in Table 3.

Table 3. Armour Wire Diameter

Over Sheath: Overall sheath comprises a layer of extruded either PVC type 9 conforming to BS 7665-4.2 or MDPE type TS2 conforming to BS 7655-10.1. LSZH can be offered as an option. The oversheath is normally black in colour. When a DC voltage test is to be performed on the oversheath, a semi conducting layer such as graphite coating shall be applied over the surface of the extruded oversheath. The nominal oversheath thickness is calculated by 0.035+D where D is the diameter immediately under the oversheath in mm. For cables with the oversheath not applied over the armour, the nominal oversheath thickness shall not be less than 1.4mm. And for cables with oversheath applied over the armour, the nominal oversheath thickness shall not be less than 1.8mm.

PHYSICAL PROPERTIES:

Operating Temperature: up to 90°C
Temperature Range: -5°C ( PVC sheath ); -20°C ( PE sheath )
Short Circuit Temperature: 250°C (short circuit duration up to 5 seconds)
Bending Radius: 12 x OD

Table 4. Nominal /Operating /Test Voltages:

     

Factory Show:

 

Package And Transportation:

 

Products Certifications:

 

 

  Testing Equipment:

 

 

Technical quality Team:

 

We are specializing in the production of  cables and wires,the spirt of us  is "quality first, reputation first, service first, customer first"

 

 

 

 

Tags: ,