Electric Power Cable 12 kV,1Cx95 mm2 CU/XLPE/SWA/PVC Power Cable,6.35/11(12)kv

Port: | Qingdao/Shanghai |
Payment Terms: | L/C,T/T |
Supply Ability: | 500 Kilometer/Kilometers per Week |
Place of Origin: | Henan China |
Brand Name: | ZMS CABLE |
Model Number: | single CORE Power Cable |
Insulation Material: | XLPE |
Type: | Medium Voltage |
Application: | Power Station |
Conductor Material: | Aluninum or Copper |
Jacket: | PVC |
Color: | Black or as per you requirement |
Company nature: | Manufacturer |
Standards: | IEC,ASTM,BS,GB,DIN |
Certification: | ISO |
Dimensions: | 0.5~1000mm2 |
No. of Cores: | single or multi-cores |
Shield/Screen: | Copper Tape, Copper Wire |
Armoring Type: | SWA, AWA, STA |
Quality of products: | High quality |
Delivery time: | On-time |
Packaging Detail: | drums for xlpe power cable |
- Service
APPLICATIONS:
The cables are designed for distribution of electrical power with nominal voltage Uo/U 19/33KV and frequency 50Hz. It is used to transmit and distribute power in power transmission and distribution system of 33kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.
STANDARD:
BS 6622
BS 7835 (LSZH Version)
CONSTRUCTION:
Conductor: Plain annealed copper or aluminium complying with IEC 60228/BS 6360. Copper
conductors shall be stranded and aluminium conductors shall be either solid or
stranded.
Conductor Screen: Extruded layer of semi-conducting cross-linkable compound is applied
over the conductor and shall cover the surface completely. The minimum thickness is 0.3mm
and the maximum resistivity shall not exceed 500 Ohm-m at 90°C.
Insulation: Insulation is of cross-linked polyethylene compound XLPE (GP8) conforming to
BS 7655-1.3 or EPR (GP7), conforming to BS 7655-1.2.
TABLE 1. INSULATION THICKNESS:
Nom. Cross Section Area | Insulation Thickness at Nom. Voltage |
19/33KV(Um=36KV) | |
mm² | mm |
70 – 185 | 8.0 |
240 | 8.0 |
300 | 8.0 |
400 | 8.0 |
Above 500 | 8.0 |
Insulaton Screen: Extruded layer of semi-conducting cross-linkable compound is applied
over the insulation. The extruded semi-conducting layer shall consist of bonded or cold
strippable semi-conducting compound capable of removal for jointing or terminating. As an
option, a semi-conducting tape may be applied over the extruded semi-conducting layer as a
bedding for the metallic layer. The minimum thickness is 0.3 mm and the maximum resistivity
is 500 Ohm-m at 90°C. The screen is tightly fitted to the insulation to exclude all air voids and
can be easily hand stripped on site.
Inner Covering; Fillers: For cables with a collective metallic layer or cables with a metallic
layer over each individual cores with additional collective metallic layers, semi-conducting
inner covering and fillers shall be applied over the laid up cores. The inner covering is made
of non hygroscopic material, except if the cable is to be made longitudinally watertight. The
inner covering shall be extruded or lapped.
The approximate thickness of extruded inner coverings is given in Table 2:
TABLE 2. APPROXIMATE THICKNESS OF EXTRUDED INNER COVERINGS
Ficititous Diameter over Laid Up Cores; | Approx. Thickness of Extruded Inner Covering; | |
mm; | mm | |
>; | <; | |
– | 25 | 1.0 |
25 | 35 | 1.2 |
35 | 45 | 1.4 |
45 | 60 | 1.6 |
60 | 80 | 1.8 |
80 | – | 2.0 |
Metallic Layer: The metallic layer shall be applied over each core or applied as a collective
screen. The metallic screen shall consist of either copper tapes or a concentric layer of
copper wires or a combination of tapes and wires. The metallic layer provides an earth
fault current path, capable of withstanding fault current to earth of 1000A for one second at
maximum temperature 160°C. Copper wires are applied over the conducting water blocking
layer with a minimum diameter of 0.5mm. And over the copper wires, copper tape with
minimum thickness of 0.1mm can be applied helically with overlap.
Total cross section of copper wire screen is shown in table 3.
TABLE 3. MINIMUM TOTAL CROSS SECTION OF COPPER WIRE SCREEN; DC RESISTANCE OF THE SCREEN
Nominal Cross-Section Area of Cable | Minimum Cross-Section of Copper Wire Screen Area | DC Resistance of the Copper Wire Screen |
mm² | mm² | mm |
up to;120 | 16 | 1.06 |
150-300 | 25 | 0.72 |
400-630 | 35 | 0.51 |
Separation Sheath (for armoured cable): The separation sheath comprises a layer of extruded PVC, PE or LSZH. The nominal thickness is calculated by 0.02Du + 0.6mm where Du is the fictitious diameter under the sheath in mm. The nominal separation sheath thickness
shall not be less than 1.2mm.
Armour (for armoured cable): The armour consists of galvanized steel wire applied over the
inner covering with diameter specified as in Table 4.
TABLE 4. ARMOUR WIRE DIAMETER
Fictitiious Diameter under the Armour | Armour Wire Diameter | |
mm | mm | |
> | < | |
– | 25 | 1.6 |
25 | 35 | 2.0 |
35 | 60 | 2.5 |
60 | – | 3.15 |