Electric Power Cable 12 kV,1Cx95 mm2 CU/XLPE/SWA/PVC Power Cable,6.35/11(12)kv

Electric Power Cable 12 kV,1Cx95 mm2 CU/XLPE/SWA/PVC Power Cable,6.35/11(12)kv
Port: Qingdao/Shanghai
Payment Terms: L/C,T/T
Supply Ability: 500 Kilometer/Kilometers per Week
Place of Origin: Henan China
Brand Name: ZMS CABLE
Model Number: single CORE Power Cable
Insulation Material: XLPE
Type: Medium Voltage
Application: Power Station
Conductor Material: Aluninum or Copper
Jacket: PVC
Color: Black or as per you requirement
Company nature: Manufacturer
Standards: IEC,ASTM,BS,GB,DIN
Certification: ISO
Dimensions: 0.5~1000mm2
No. of Cores: single or multi-cores
Shield/Screen: Copper Tape, Copper Wire
Armoring Type: SWA, AWA, STA
Quality of products: High quality
Delivery time: On-time
Packaging Detail: drums for xlpe power cable
PRODUCT DESCRIPTION

 

  • Service

APPLICATIONS:

The cables are designed for distribution of electrical power with nominal voltage Uo/U 19/33KV and frequency 50Hz. It is used to transmit and distribute power in power transmission and distribution system of 33kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.

STANDARD:

BS 6622

BS 7835 (LSZH Version)

CONSTRUCTION:

Conductor: Plain annealed copper or aluminium complying with IEC 60228/BS 6360. Copper

conductors shall be stranded and aluminium conductors shall be either solid or

stranded.

Conductor Screen: Extruded layer of semi-conducting cross-linkable compound is applied

over the conductor and shall cover the surface completely. The minimum thickness is 0.3mm

and the maximum resistivity shall not exceed 500 Ohm-m at 90°C.

Insulation: Insulation is of cross-linked polyethylene compound XLPE (GP8) conforming to

BS 7655-1.3 or EPR (GP7), conforming to BS 7655-1.2.

TABLE 1. INSULATION THICKNESS:

Nom. Cross Section Area Insulation Thickness at Nom. Voltage
19/33KV(Um=36KV)
mm² mm
70 – 185 8.0
240 8.0
300 8.0
400 8.0
Above 500 8.0

Insulaton Screen: Extruded layer of semi-conducting cross-linkable compound is applied

over the insulation. The extruded semi-conducting layer shall consist of bonded or cold

strippable semi-conducting compound capable of removal for jointing or terminating. As an

option, a semi-conducting tape may be applied over the extruded semi-conducting layer as a

bedding for the metallic layer. The minimum thickness is 0.3 mm and the maximum resistivity

is 500 Ohm-m at 90°C. The screen is tightly fitted to the insulation to exclude all air voids and

can be easily hand stripped on site.

Inner Covering; Fillers: For cables with a collective metallic layer or cables with a metallic

layer over each individual cores with additional collective metallic layers, semi-conducting

inner covering and fillers shall be applied over the laid up cores. The inner covering is made

of non hygroscopic material, except if the cable is to be made longitudinally watertight. The

inner covering shall be extruded or lapped.

The approximate thickness of extruded inner coverings is given in Table 2:

TABLE 2. APPROXIMATE THICKNESS OF EXTRUDED INNER COVERINGS

Ficititous Diameter over Laid Up Cores; Approx. Thickness of Extruded Inner Covering;
mm; mm
>; <;  
25 1.0
25 35 1.2
35 45 1.4
45 60 1.6
60 80 1.8
80 2.0

Metallic Layer: The metallic layer shall be applied over each core or applied as a collective

screen. The metallic screen shall consist of either copper tapes or a concentric layer of

copper wires or a combination of tapes and wires. The metallic layer provides an earth

fault current path, capable of withstanding fault current to earth of 1000A for one second at

maximum temperature 160°C. Copper wires are applied over the conducting water blocking

layer with a minimum diameter of 0.5mm. And over the copper wires, copper tape with

minimum thickness of 0.1mm can be applied helically with overlap.

Total cross section of copper wire screen is shown in table 3.

TABLE 3. MINIMUM TOTAL CROSS SECTION OF COPPER WIRE SCREEN; DC RESISTANCE OF THE SCREEN

Nominal Cross-Section Area of Cable Minimum Cross-Section of Copper Wire Screen Area DC Resistance of the Copper Wire Screen
mm² mm² mm
up to;120 16 1.06
150-300 25 0.72
400-630 35 0.51

Separation Sheath (for armoured cable): The separation sheath comprises a layer of extruded PVC, PE or LSZH. The nominal thickness is calculated by 0.02Du + 0.6mm where Du is the fictitious diameter under the sheath in mm. The nominal separation sheath thickness

shall not be less than 1.2mm.

Armour (for armoured cable): The armour consists of galvanized steel wire applied over the

inner covering with diameter specified as in Table 4.

TABLE 4. ARMOUR WIRE DIAMETER

Fictitiious Diameter under the Armour Armour Wire Diameter
mm mm
> <  
25 1.6
25 35 2.0
35 60 2.5
60 3.15