BS 215 standard acsr rabbit conductor price/Aluminum Conductors Steel Reinforced

Port: | Any port in China |
Payment Terms: | L/C,D/P,T/T |
Supply Ability: | 1000 Kilometer/Kilometers per Month |
Place of Origin: | Henan China |
Brand Name: | Jinshui |
Model Number: | acsr moose conducto |
Insulation Material: | Bare |
Type: | High Voltage |
Application: | Construction, power station |
Conductor Material: | Aluminum and steel wire |
Jacket: | Bare |
Standard: | BS IEC ASTM DIN |
Certificate: | ISO9001 |
Usage: | Distribution Line and Transmission line |
Product name: | BS 215 standard acsr rabbit conductor price |
Packaging Detail: | Wooden Drums/ Steel-wooden Drums for BS 215 standard acsr rabbit conductor price/Aluminum Conductors Steel Reinforced |
BS 215 standard acsr rabbit conductor price/Aluminum Conductors Steel Reinforced
1 Application of acsr conductor/Aluminum Conductor Steel Reinforced
The bare conductor:AAC,AAAC,ACSR,AACSR,ACAR and Galvanized steel wire, are used in overhead electrical power transmission and distribution lines with various grade voltage.
Construction: Bare aluminum alloy 1350-H19 wires, concentrically stranded around a Class A galvanized coated steel core wire.
ACSR consists of a galvanized steel core of 1 wire, 7 wires, 19 wires etc. surrounded by concentric layers of aluminum wire.
2 Standards of acsr conductor/Aluminum Conductor Steel Reinforced
Our Bare conductor can meet or exceedthe item of cable international standards,
such as:IEC 61089, BS 215 part1(AAC), BS 215 part2, BS 324201 (AAAC), DIN 48201 part 5 (AAC), DIN 48204,
ASTM B231(AAC), ASTM B232(ACSR), BS EN 50182, BS EN 50183(AAAC), GB/T 1179-2008. Also we accept the OEM and the new design cable as customers.
3. Technical data
Manufacturing Standards
GB/T 1179-2008, IEC 61089, EN 50182, DIN 48204, BS 215 Part 2, ASTM B232, NF C 34-120 or as required.
ACSR Technical Characteristics Based on Standard BS 215-2 | |||||||||
Code name | Nominal aluminium area | Stranding and wire diameter | Sectional area of aluminium | Total sectional area | Approx. overall diameter | Approx. mass | Calculated D.C. resistance at 20oC | Calculated breaking load | |
Al | Steel | ||||||||
mm2 | No./mm | mm2 | mm2 | mm | kg/km | Ω/km | kN | ||
RABBIT | 50 | 6/3.35 | 1/3.35 | 52.88 | 61.7 | 10.05 | 214 | 0.5426 | 18.35 |
DOG | 100 | 6/4.72 | 7/1.57 | 105 | 118.5 | 14.15 | 394 | 0.2733 | 32.7 |
WOLF | 150 | 30/2.59 | 7/2.59 | 158.1 | 194.9 | 18.13 | 726 | 0.1828 | 69.2 |
DINGO | 150 | 18/3.35 | 1/3.35 | 158.7 | 167.5 | 16.75 | 506 | 0.1815 | 35.7 |
LYNX | 175 | 30/2.79 | 7/2.79 | 183.4 | 226.2 | 19.53 | 842 | 0.1576 | 79.8 |
Technical Characteristics Based on Standard BS EN50182 | |||||||||
Code name | Areas | No. of wires and wire diameter | Conductor diameter | Linear mass | Rated strength | D.C. resistance at 20oC | |||
Al | Steel | Total | Al | Steel | |||||
mm2 | mm2 | mm2 | No./mm | No./mm | mm | kg/km | kN | Ω/km | |
FOX | 36.7 | 6.11 | 42.8 | 6/2.79 | 1/2.79 | 8.37 | 148.1 | 13.21 | 0.7812 |
BEAR | 264.4 | 61.7 | 326.1 | 30/3.35 | 7/3.35 | 23.5 | 1213.4 | 111.5 | 0.1093 |
SHEEP | 375.1 | 87.5 | 462.6 | 30/3.99 | 7/3.99 | 27.9 | 1721.3 | 156.3 | 0.0771 |
Technical Characteristics Based on Standard DIN 48204 / DIN EN50182 | |||||||||
Code name | Areas | No. of wires and wire diameter | Conductor diameter | Linear mass | Rated strength | D.C. resistance at 20oC | |||
Al | Steel | Total | Al | Steel | |||||
mm2 | mm2 | mm2 | No./mm | No./mm | mm | kg/km | kN | Ω/km | |
50/8 | 48.3 | 8.04 | 56.3 | 6/3.20 | 1/3.20 | 9.6 | 194.8 | 16.81 | 0.5939 |
95/15 | 94.4 | 15.3 | 109.7 | 26/2.15 | 7/1.67 | 13.6 | 380.6 | 34.93 | 0.306 |
120/20 | 121.6 | 19.8 | 141.4 | 26/2.44 | 7/1.90 | 15.5 | 491 | 44.5 | 0.2376 |
240/40 | 243.1 | 39.5 | 282.5 | 26/3.45 | 7/2.68 | 21.8 | 980.1 | 85.12 | 0.1188 |
300/50 | 304.3 | 49.5 | 353.7 | 26/3.86 | 7/3.00 | 24.4 | 1227.3 | 105.09 | 0.0949 |
550/70 | 549.7 | 71.3 | 620.9 | 54/3.60 | 7/3.60 | 32.4 | 2077.2 | 166.32 | 0.0526 |
Technical Characteristics Based on Standard ASTM B 232 | |||||||||
Code Words | Size | No. of wires and wire diameter | Approx. overall diameter | Linear mass | Rated Strength | Calculated D.C. resistance at 20oC | |||
Al | Steel | ACSR/GA | ACSR/GB | ACSR/HS | |||||
AWG / kcmil | No./mm | No./mm | mm | kg/km | kN | kN | kN | Ω/km | |
Sparrow | 2 | 6/2.67 | 1/2.67 | 8.01 | 135.8 | 12.67 | 12.27 | 13.38 | 0.8542 |
Pigeon | 3/0 | 6/4.25 | 1/4.25 | 12.75 | 344 | 29.44 | 28.51 | 31.8 | 0.3372 |
Penguin | 4/0 | 6/4.77 | 1/4.77 | 14.31 | 433.3 | 37.14 | 35.94 | 40.07 | 0.2677 |
Wooden Drums/ Steel-wooden Drums for BS 215 standard acsr rabbit conductor price/Aluminum Conductors Steel Reinforced
Overhead bare conductor has been widely used in power transmission lines with various voltage levels,because they have such good characteristics as simple structure,convenient installation and maintenance,low cost large transmission capacity.And they are also suitable for laying across rivers valleys and the places where special geographical features exist.
1. Are you the factory or trading company?
We are the manufacturer and 13 years gold supplier on alibaba.We are engaged in exporting cables for nearly 15 years.
2. When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your e-mail so that we will regard your inquiry priority.
3. How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. Sample is free, but the freightcharge should be paid.
4. What is the payment terms?
30% deposit by T/T,70% T/T after checking the copy of B/L. Or irrevocable L/C at sight .
5. What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.
- Next: BS215 ACSR Horse/Beaver Cable 70mm2 acsr bare conductor
- Previous: Hot new products abc cable sizes price aerial bundled overhead cable