11kv XLPE PVC UNDERGROUND CABLE INSULATED ELECTRICAL POWER CABLE

| Port: | qingdao | 
| Payment Terms: | L/C,T/T,Western Union,MoneyGram | 
| Supply Ability: | 500 Kilometer/Kilometers per Week good quality on 11kv UNDERGROUND CABLE | 
| Place of Origin: | Henan China | 
| Brand Name: | hongda | 
| Model Number: | 11kv UNDERGROUND CABLE | 
| Insulation Material: | XLPE | 
| Type: | Medium Voltage | 
| Application: | Industrial | 
| Conductor Material: | Copper | 
| Jacket: | PVC | 
| guarantee period: | 50 years | 
| model1: | electrical power cable | 
| model2: | cu/copper/al/aluminum xlpe pvc swa cable | 
| model3: | 11kv UNDERGROUND CABLE | 
| standard: | astm gb/t bs din iec | 
| Delivery Detail: | 20 days | 
| Packaging Detail: | export drums, metal drum, or according to your requires | 
11kv UNDERGROUND CABLE
MV XLPE INSULATED ELECTRICAL UNDERGROUND POWER CABLE
electrical power cable copper conductor,xlpe insulated, pvc sheath,coated electric cable ,steel wire armoured underground cable
Standard: 
It is manufacture under GB/T12706-2002 standard(The same as IEC60502).
Application of 11kv XLPE PVC CABLE :
For power transmission and distribution lines with rated power frequency voltage 8.7/15KV.
Construction of 11kv UNDERGROUND CABLE :
Standard: According to IEC60502-2, 61034 and 60754
Conductor: Copper or aluminum
Conductor screen: Semi-conductive compound
Insulation: XLPE
Insulation screen: Semi-conductive compound
Metal screen: Copper tape
Inner sheath: PVC
Armor: Aluminum or Steel wire or tape
Outer sheath: PVC
Technical data:
Temperature range: 0° C to +90°C
Max conductor temperature: 90 °C
Max short-circuit temperature at conductor: 250 °C (max. 5 s)
Min bending radius:Fixed 20×D ( for single-core cable), Fixed 15×D ( for three-cores cable)
| China Type | Description of 11kv UNDERGROUND CABLE | Application of 11kv UNDERGROUND CABLE | |
| Cu | Al | ||
| YJV | YJLV | XLPE insulation PVC sheath power cable (Cu/XLPE/PVC) | To be laid indoors, in tunnel, cable furrow or pipe, the cable couldn't bear mechanical force outside | 
| YJY | YJLY | XLPE insulation PE sheath power cable (Cu/XLPE/PE) | |
| YJV22 | YJLV22 | XLPE insulation, steel tape armor, PVC sheath power cable (Cu/XLPE/PVC/STA/PVC) | To be laid underground, the cable could bear certain mechanical force, but it couldn't bear great pulling force. | 
| YJV23 | YJLV23 | XLPE insulation, steel tape armor, PE sheath power cable (Cu/XLPE/PVC/STA/PE) | |
| YJV62 | YJLV62 | XLPE insulation, no magnetism steel tape armor, PE sheath power cable | |
| YJV32 | YJLV32 | XLPE insulation, thin steel-wire armor, PVC sheath power cable (Cu/XLPE/PVC/SWA/PVC) | Be applicable to the well, water inside and fall in the bad soil, the cable cans bear the equal dint outside the machine with pull the dint . | 
| YJV72 | YJLV72 | XLPE insulation, have no the magnetism thick steel-wire armor, PVC sheath power cable | |
| YJV42 | YJLV42 | XLPE insulation, thick steel-wire armor, PVC sheath power cable | Be applicable to the well, underwater with the bottom of sea, the cable cans bear the bigger pressure with lead to pull the dint. | 
Application:
11kv UNDERGROUND CABLE for power networks, underground, outdoors and in cable ducting.
Standards:BS6622
Conductor:Class 2 stranded plain copper conductor to BS EN 60228:2005 (previously BS6360)
Conductor screen:Semi-conducting material
Insulation:XLPE (Cross-Linked Polyethylene) Type GP8 to BS7655
Insulation Screen:Semi-conducting material
Metallic Screen:Individual and overall copper tape screen to BS6622
Filler:PETP (Polyethylene Terephthalate) fibres
Separator:Binding tape
Bedding:PVC (Polyvinyl Chloride) Type TM1 to BS7655
Armouring:
Single Core: Aluminium Wire Armoured (AWA)
Multi-core: Steel Wire Armoured (SWA)
Sheath:PVC (Polyvinyl Chloride) Type TM1 to BS7655
Colour:Red or Black
Voltage Rating:600/1000V—- 19000/33000V
Temperature Rating:0°C to +90°C
Minimum Bending Radius:
Single Core: 15 x overall diameter
Three Core: 12 x overall diameter
(Single Core 12 x overall diameter and 3 core 10 x overall diameter where bands are positioned adjacent to joint or terminations provided that the bending is carefully controlled by the use of a former)
11-35kv 11kv UNDERGROUND CABLE
| Cable Type | Nominal Cross Sectional Areamm2 | Nominal Diameter Under Armourmm | Nominal Diameter Over Armourmm | Nominal Diameter Overallmm | Nominal Weightkg/Km | Continuous Current Rating in Ground – TrefoilAmps | Continuous Current Rating in Ground – FlatAmps | 
|---|---|---|---|---|---|---|---|
| Copper | 1 x 70 | 32.6 | 36.6 | 41.0 | 2300 | 270 | 280 | 
| Copper | 1 x 95 | 34.3 | 38.3 | 42.9 | 2650 | 320 | 335 | 
| Copper | 1 x 120 | 35.9 | 39.9 | 44.5 | 3000 | 360 | 380 | 
| Copper | 1 x 150 | 37.5 | 42.5 | 47.3 | 3500 | 410 | 430 | 
| Copper | 1 x 185 | 39.3 | 44.3 | 49.3 | 4000 | 455 | 485 | 
| Copper | 1 x 240 | 41.7 | 46.7 | 51.7 | 4650 | 520 | 560 | 
| Copper | 1 x 300 | 44.2 | 49.2 | 54.4 | 5450 | 580 | 640 | 
| Copper | 1 x 400 | 47.3 | 52.3 | 57.7 | 6350 | 650 | 730 | 
| Copper | 1 x 500 | 50.5 | 55.5 | 61.1 | 7600 | 710 | 830 | 
| Copper | 1 x 630 | 54.2 | 59.2 | 65.0 | 9150 | 760 | 940 | 
| Copper | 1 x 800 | 60.5 | 65.5 | 71.6 | 11100 | 810 | 1060 | 
| Copper | 1 x 1000 | 65.0 | 70.0 | 76.5 | 13400 | 860 | 1170 | 
| Copper | 3 x 50 | 65.1 | 71.4 | 78.2 | 9150 | 210 | 210 | 
| Copper | 3 x 70 | 68.8 | 75.1 | 82.1 | 10300 | 250 | 250 | 
| Copper | 3 x 95 | 72.6 | 78.9 | 86.1 | 11600 | 300 | 300 | 
| Copper | 3 x 120 | 76.3 | 82.6 | 90.0 | 12800 | 340 | 340 | 
| Copper | 3 x 150 | 79.3 | 85.6 | 93.2 | 14050 | 380 | 380 | 
| Copper | 3 x 185 | 83.4 | 89.7 | 97.5 | 15650 | 430 | 430 | 
| Copper | 3 x 240 | 88.8 | 95.1 | 103.3 | 18200 | 500 | 500 | 
| Copper | 3 x 300 | 93.9 | 100.2 | 108.8 | 21100 | 540 | 540 | 
| Copper | 3 x 400 | 100.8 | 107.1 | 116.1 | 24200 | 600 | 600 | 
| Aluminium | 1 x 70 | 32.6 | 36.6 | 41.0 | 1850 | 210 | 215 | 
| Aluminium | 1 x 95 | 34.3 | 38.3 | 42.9 | 2100 | 250 | 260 | 
| Aluminium | 1 x 120 | 35.9 | 39.9 | 44.5 | 2250 | 280 | 295 | 
| Aluminium | 1 x 150 | 37.5 | 42.5 | 47.3 | 2600 | 320 | 330 | 
| Aluminium | 1 x 185 | 39.3 | 44.3 | 49.3 | 2850 | 360 | 375 | 
| Aluminium | 1 x 240 | 41.7 | 46.7 | 51.7 | 3150 | 415 | 440 | 
| Aluminium | 1 x 300 | 44.2 | 49.2 | 54.4 | 3600 | 475 | 495 | 
| Aluminium | 1 x 400 | 47.3 | 52.3 | 57.7 | 4000 | 540 | 570 | 
| Aluminium | 1 x 500 | 50.5 | 55.5 | 61.1 | 4500 | 610 | 650 | 
| Aluminium | 1 x 630 | 54.2 | 59.2 | 65.0 | 5250 | 680 | 750 | 
| Aluminium | 1 x 800 | 60.5 | 65.5 | 71.6 | 6150 | 770 | 860 | 
| Aluminium | 1 x 1000 | 65.0 | 70.0 | 76.5 | 7200 | 859 | 960 | 
| Aluminium | 3 x 50 | 65.1 | 71.4 | 78.2 | 8300 | 160 | 160 | 
| Aluminium | 3 x 70 | 68.8 | 75.1 | 82.1 | 9050 | 195 | 195 | 
| Aluminium | 3 x 95 | 72.6 | 78.9 | 86.1 | 9800 | 230 | 230 | 
| Aluminium | 3 x 120 | 76.3 | 82.6 | 90.0 | 10600 | 265 | 265 | 
| Aluminium | 3 x 150 | 79.3 | 85.6 | 93.2 | 11350 | 300 | 300 | 
| Aluminium | 3 x 185 | 83.4 | 89.7 | 97.5 | 12250 | 335 | 335 | 
| Aluminium | 3 x 240 | 88.8 | 95.1 | 103.3 | 13700 | 380 | 380 | 
| Aluminium | 3 x 300 | 93.9 | 100.2 | 108.8 | 15500 | 435 | 435 | 
| Aluminium | 3 x 400 | 100.8 | 107.1 | 116.1 | 16750 | 490 | 490 | 
welcome to send us request on 11kv UNDERGROUND CABLE
- Next: ACSR Rabbit Horse Dog Wolf Mink conductor price
- Previous: 600v UL standard copper conductor type TW electrical wire
 