XLPE Rodent resistant cable 11KV 300mm cable

Port: | Tianjin |
Payment Terms: | L/C,T/T,Western Union,MoneyGram |
Supply Ability: | 5000 Kilometer/Kilometers per Month |
Place of Origin: | Hebei China |
Brand Name: | Haohua |
Model Number: | Power Cable |
Type: | Insulated |
Application: | Overhead |
Conductor Material: | Copper |
Conductor Type: | Stranded |
Insulation Material: | XLPE/PVC |
Name: | power cable |
Insulation mterial: | XLPE/LSZH |
Conductor: | Copper |
Advantage: | Acid and alkali resistance |
Certificate: | ISO9001,ISO14001,CCC , CE |
Voltage: | 11kV |
Color: | Red, yellow, blue, green, black, white, or as required |
Standard: | IEC60502 AS/NZS 5000.1 |
Delivery Detail: | 2-3 weeks or as to the buyers' request |
Packaging Detail: | Power cable should be supplied in Steel drum. Cable piece length should be of 500 meter length or as specified by the customer at the time of order. |
11kV XLPE Rodent resistant Power cable
Conductor: copper or aluminium
Insulation: XLPE/PVC
Armored: Steel or steel wire
Jacket: PVC/LSZH
Voltage: 1-35KV
Core No.: 1, 3
Standard: IEC60502, IEC60331
The main features of the flame retardant XLPE power cable is hard to catch on fire or that the continuous burning of cables is very limited when it is on fire. It applies to the places with many cables laid tightly together such as power generated station, subway, tunnel, high-storey building and other places concerning to fire security and its lifesaving.
Operating characteristics:
(1) Rated voltage U0/U is 0.6/1 kilovolts.
(2) Maximum rated temperature of cable conductor is 90℃
(3) Maximum conductor temperature is lower than 250℃ when cable is shorted for less than 5 seconds.
(4) Ambient temperature is not lower than 0℃ and its minimum bending radius is as follows when cable is installed: for single-core calbe-20(D+d), unit: millimeter for multi-core cable-15(D+d), unit: millimeter
Note: D denotes the overall diameter of cable, while means the nominal diameter of the main conductor, unit: millimeter.
Technical Parameter:
Calculation condition of the ampacity ambient temperature is 25℃
conductor working temperature is 90℃
soil heat resulted from water migration when it operates continuously.
gap between axis of cable and surface of ground is 1000 millimeter when it is laid in ground.
for multi-core cable, gap of axis of cable is 3 times O.D.
Production Range:
Cores No. |
1 |
2 |
3 |
4 |
3+1 |
5 |
4+1 |
3+2 |
Nominal cross sectional areas mm2 |
1.0 ~ 800 2.5 ~ 800 10 ~ 800 |
1.0 ~ 300 2.5 ~ 300 4 ~ 300 4 ~ 300 10 ~ 300 |
1.0 ~ 400 2.5 ~ 400 4 ~ 400 4~ 400 10 ~ 400 |
1.0 ~ 400 2.5 ~ 400 4 ~ 400 4~ 400 10 ~ 400 |
1.0 ~ 400 4.0 ~ 400 4~ 400 4 ~ 400 10 ~ 400 |
1.0 ~ 400 2.5 ~ 400 4 ~ 400 4~ 400 10 ~ 400 |
1~ 400 4~ 400 4 ~ 400 4 ~ 400 10 ~ 400 |
1~ 400 4 ~ 400 4 ~ 400 4~ 400 10 ~ 400 |
Cell phone: 0086-15106980528 Skype: hongliangcablesales7 QQ: 469855079
- Next: MV cable 15 KV XLPE insulated 1 X 185 mm 1Cores copper conductor unarmored
- Previous: PVC/XLPE Insulated Multi core Electrical cable Size 16mm2 25mm2 50mm2 70mm2 95mm2 120mm2