XLPE 11kV SWA Armoured Electrical Cable Three Cores MV Copper Armoured Cable YJV32

XLPE 11kV SWA Armoured Electrical Cable Three Cores MV Copper Armoured Cable YJV32
Port: Shanghai
Payment Terms: L/C,D/P,T/T,Western Union,Alibaba Trade Assurance
Supply Ability: 10000 Meter/Meters per Day
Place of Origin: Shanghai China
Brand Name: SHENGHUA
Model Number: YJV32 Three Cores MV Copper Armoured Cable
Insulation Material: XLPE
Type: Medium Voltage
Application: Power Station
Conductor Material: Copper
Jacket: PVC
Model name: XLPE 11kV SWA Armoured Electrical Cable Three Cores MV Copper
Size: 1.5~630mm2
Nos.of cores: 3
Voltage: 3.6~35kV
Armoured: Steel tape or steel wire or aluminum wire optional
Screen/sheild: copper wire or copper tape optional
Insulation color: many optional color
Sheath color: Black or according to clients request
Flame retardant: yes
Certificate: KEMA/CE/IEC/ISO/CCC etc.
Packaging Detail: wooden drum or customerized

XLPE 11kV SWA Armoured Electrical Cable Three Cores MV Copper Armoured Cable YJV32

Product details

PRODUCT DETAILS

 

Structure

 

1 ….. stranded bare copper
2 ….. inner layer of semi-conducting material
3 ….. core insulation of cross-linked polyethylene
4 ….. outer layer of semi-conducting material
5 ….. semi-conducting tape
6 ….. screen of copper wires

7 ….. Fillers strip, Yarn, or Paper
8 ….. Non woven Wrapping tape or Flame Retardant

9 ….. Extruded PVC Inner Covering

10 …. Galvanized Steel Tape Armoured
11 …. Overall Sheath: polyvinylchloride (PVC) or FR-PVC, PE, LSOH

 

 

Application

Medium voltage power cable for static application in ground, within and outside facilities, outdoor, in cable canals, in water, in conditions where cables are not exposed to heavier mechanical stress and tensile strain.

Due to its very low factor of dielectric loss, which remains constant over its entire operating lifetime, and owing to excellent insulation property of XLPE-material, firmly longitudinally spliced with inner and external screen of semi-conductive material (extruded in one process), the cable has a high operating reliability.

Used in transformer stations, switching blocks, in electric power plants and industrial plants.

To avoid the effects of external impact, the adhering semi-conductive layer extruded between conductor and insulation, along with concentric copper conductor, secures restriction of electric field and resistance to partial discharges.

 

 

Standard

 

International: IEC 60502-2, IEC 60228

China: GB/T 12706.2-2008

Other standards such as BS,DIN and ICEA upon request

 

 

Specification

 

MV(6 to 35kv) Power Cable
Model and Description Uo/U(Um)=3.6/6(7.2), 6/6(7.2), 6/10(12), 8.7/10(12), 8.7/15(17.5), 12/20(24), 18/30(36), 21/35(40.5), 26/35(40.5)kV No.of Core Conductor cross-section area(mm2)
xlpe insulation 1 core 3 core 10 16 25 35 70 95 120 150 185 240 300 400 500 630 sq mm
Cu core Al Core
YJV, N2XSY;PVC sheathed power cable YJLV, NA2XSY; PVC sheathed power cable
YJV22;steel tape armoured,PVC sheathed power cable YJLV22;steel tape armoured,PVC sheathed power cable
YJV32,YJV42;steel wire armoured ,PVC sheathed power cable YJLV32,YJLV42;steel wire armoured ,PVC sheathed power cable
pvc insulation
Cu Core Al Core
VV(VY);PVC(PE)sheathed power cable VLV(VLY);PVC(PE)sheathed power cable
VV22(VV23);steel tape armoured,PVC(PE)sheathed power cable VLV22(VLV23);steel tape armoured,PVC(PE)sheathed power cable
VV32(VV33),VV42(VV43);steel wire armoured ,PVC(PE)sheathed power cable VLV32(VLV33),VLV42(VLV43);steel wire armoured ,PVC(PE)sheathed power cable

 

Technical data

 

Maximum Conductor Temperature: under normal (90°C), emergency (130°C) or short circuit no more than 5 s (250°C) conditions.

Min. Ambient Temp. 0°C, after installation and only when cable is in a fixed position

Min. Bending Radius: 20 x cable O.D for single-core non-armoured cables

15 x cable O.D for single-core armoured cables

15 x cable O.D for multi-core non-armoured cables

12 x cable O.D for multi-core armoured cables

 

Certificate

 

ISO,CE, KEMA ,IEC, RoHS, CCC, P3C and more others at request

 

 

Ordering

 

Rated Voltage

Application Standard:IEC/BS/UL/GB

Number of Cores

Conductor Size $ Construction

Type of Insulation

Armored or unarmored. If armour, the armour type & material

The Requirement of Sheath

Length of Cable & Packing Requirement

Other Requirement

 

 

Technical Parameter

 

Nom. Cross-section of conductor Strands No./Dia. Of Conductor Insulation Thickness Inner Sheath Thickness Dia. Of Armor Wire Sheath Thickness Approx. O.D. Approx.Weight Max. D.C Resistance of Conductor (20 ℃) Testing Voltage A.C Current Rating
mm2 pc/mm mm mm mm mm (mm) kg/km Ω /km kV/5min In air (A) In soil(A)
3 × 25 7/2.14 3.4 1.3 2.5 2.5 49.0 4579 0.727 21 120 125
3 × 35 7/2.52 3.4 1.3 2.5 2.6 52.0 5097 0.524 21 140 155
3 × 50 10/2.52 3.4 1.4 2.5 2.7 54.0 5802 0.387 21 165 180
3 × 70 14/2.52 3.4 1.5 2.5 2.8 58.0 6788 0.268 21 210 220
3 × 95 19/2.52 3.4 1.5 2.5 2.9 62.0 7812 0.193 21 255 265
3 × 120 24/2.52 3.4 1.6 2.5 3.1 65.0 8929 0.153 21 290 300
3 × 150 30/2.52 3.4 1.7 2.5 3.2 68.0 10125 0.124 21 330 340
3 × 185 37/2.52 3.4 1.7 3.15 3.3 72.0 12403 0.0991 21 375 380
3 × 240 48/2.52 3.4 1.8 3.15 3.5 78.0 14646 0.0754 21 435 435
3 × 300 61/2.52 3.4 1.9 3.15 3.7 83.0 17014 0.0601 21 495 48

Certification
Factory show

FACTORY SHOW

 
PRO.&INS. Process

PRO.&INS. PROCESS

 

Note:
1. The process of production and inspection applies to Electric Power Cable, Control Cable, Aerial Cable, House Wiring Cable and so on. The process is not all same for different types of products.
2. The process with the mark is for medium voltage power cable.

PACKING AND SHIPPING

 
Packing and shipping

We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.

Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.

After-service

 

 

Quote Request Information

 

1. Material of conductor/insulation/sheath.

2. Voltage classes.

3. Cross section, Short circuit current capacity, tension strength.

4. Order Quantity

 

 

Our Services

 

♦ We are the one of biggest manufacture of electric wire and power cable in China and has more than 20 years producing and marketing experience.

♦ We accept OEM. The cable size and material are customized.Ur own logo and

own design are welcome. We will produce according to your requirement and description;

♦ Please send us inquiry for more products info and we will give you feedback in 12 hours.

FAQ

 

1. Shipping: By sea or air due to heavy weight. Samples will be send by DHL, Fedex. etc

2. Payment: We accept T/T, L/C , just choose what you like

3. Delivery time: Generally 7~10 working days upon receipt deposit. According to the quantity.

4. MOQ: Generally our MOQ is 1000meters. samples below 20 centimeter can be provided freely.

 

 

You can contact me directly for soonest response 🙂

 

 

Tags: , ,

Contact us

 

 

 

Search