STA armoured PE sheathed power Cable
- Standards: UL758 approval
- Description:Applications: sound broadcast, audio instrumentation and computer cable for EIA RS-232
- Rated temperature: 80°C
- Rated voltage: 0.6/1 KV
- Color-coded semi-rigid PVC insulation
- Tinned stranded, copper conductor
- Tinned stranded, copper drain wire
- Cores cabled under aluminum Mylar shield
- Single shield computer cable:
- PVC jacketed unpaired computer and data transmission cable
- Double shield computer cable:Passed UL VW-1 vertical flame test
- PVC jacketed computer and data transmission cable
- Tinned copper braided shield, 85% coverage
| Items | Description | Application | Core | Section |
| YJV |
Copper core XLPE insulated PVC sheathed power cable |
Can be laid in indoors, tunnels and pipelines can not afford cable mechanical external force. Cable can not afford to pull.
|
1 2 3 | 1.5-600mm2 |
| YJY YJLY |
Copper core XLPE insulated PVC sheathed power cable |
Can be laid in indoors, tunnels and pipelines can not afford cable mechanical external force. Cable can not afford to pull | 1 2 3 4 | 1.5-600mm2 |
| YJV22 YJLV22 |
Copper core XLPE insulated Galvanized steel Tape armoured PVC sheathed power cable |
Can be laid in indoors, tunnels and pipelines can not afford cable mechanical external force. Cable can not afford to pull | 2 3 4 | 1.5-630mm2 |
| YJV23 YJLV23 |
Copper core XLPE insulated Galvanized steel Tape armoured PE sheathed |
Can be laid in indoors, tunnels and pipelines can not afford cable mechanical external force. Cable can not afford to pull. |
3 4 5 3+1 4+1 |
1.5-630mm2 |
| YJV32 YJLV32 |
Copper core XLPE insulated Galvanized steel wire armoured PVC sheathed power cable |
Can be laid in indoors, tunnels and pipelines can not afford cable mechanical external force. Cable can not afford to pull. |
2 3 4 5 3+1 4+1 |
1.5-630mm2 |
| YJV33 YJLV33 |
Copper core XLPE insulated Galvanized steel wire armoured PE sheathed power cable |
Can be laid in indoors, tunnels and pipelines can not afford cable mechanical external force. Cable can not afford to pull. |
2 3 4 5 3+1 4+1 | |
| ZR =Flame Rerardent | ZR-YJV ZR-YJLV YJV22 YJLV22 YJV32 YJLV32 | SAME WITH ABOVE | SAME | SAME |
Type & Name
VV——- Copper-core PVC insulated PVC sheathed power cable
VLV—– Aluminum-core PVC insulated PVC sheathed power cable
VV22 —–Copper-core PVC insulated PVC sheathed steel-tape armored power cable
VLV22—- Aluminum-core PVC insulated PVC sheathed steel-tape armored power cable
VV32 ——copper-core PVC insulated PVC sheathed fine steel wire armored power cable
VLV32—– Aluminum-core PVC insulated PVC sheathed fine steel wire armored power cable
Application: In room, tunnel, cable channel and underground, able to bear mechanical force.
Products Certifications:
Testing Equipment:
Technical quality Team: