Three Phase Manufacture Electric Cable and PVC Sheathed XLPE Insulated Electrical MV Armoured Cable

Port: | Shanghai |
Payment Terms: | L/C,T/T |
Supply Ability: | 10000 Meter/Meters per Day |
Place of Origin: | Shanghai China |
Brand Name: | OEM |
Model Number: | Medium voltage |
Insulation Material: | XLPE |
Type: | Medium Voltage |
Application: | Power Station |
Conductor Material: | Copper |
Jacket: | PVC |
Product name: | 3 phase MV Armoured Power Cable |
Rated voltage: | HV 11kV 15kV 33kV 6/10kV 8.7/15kV 18/30kV 26/35kV |
Armour: | Steel tape, Steel wire or Aluminum wire armor, or unarmored |
Standard: | IEC 60502 |
Color: | Customized |
Special requiremets: | Fire-resistant, flame retardant, low smoke halogen free |
Conductor: | Stranded Copper |
Insulation: | XLPE Insulation |
Sheath: | PVC, ZR-PVC, PE, LSOH |
Warranty: | 2 Years |
Delivery Detail: | As per schedule |
Packaging Detail: | Wooden drum packing or customerized |
Three Phase Manufacture Electric Cable and PVC Sheathed XLPE Insulated Electrical MV Armoured Cable
Applications
Used for Power transmission and distribution line with voltage rated at 35kv and below.
For Layling indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Standards
Description
CU/XLPE/STA/PVC, IEC 60502
IEC 60502, IEC 60228, GB/T 12706.1-2008.
CE, CCC, KEMA
Constructions
Conductor: Circular stranded copper conductor, conforms to IEC 60228 class 2
Insulation: XLPE/A
Inner Covering: PVC
Armour: Galvanized Steel Wire or tape
Sheath: PVC type ST2 to IEC 60502, black
Note: Insulation color as per standards or customer requirement
Conductor |
Compact Stranded Copper Conductor, Class 2 as per IEC 60228 |
Circular solid Copper Conductor, Class 1 as per IEC 60228 |
|
Flexible Stranded Copper Conductor, Class 5 as per IEC 60228 |
|
Conductor Screen |
Semi-conductor (MV only) |
Insulation |
XLPE(Cross-linked polyethylene) |
Insulation Screen |
Semi-conductor (MV only) |
Metalic Shield |
Copper Tape Screen or Copper wire & copper tape Shield (MV must, LV optional) |
Filler |
Fillers strip |
Wrapping Tape |
Non woven wrapping tape or lsoh wrapping tape |
Inner Covering |
Extruded PVC, or LSOH (MV only) |
Armour |
Steel Tape Armour, Steel Wire or Aluminium Wire Armor optional |
Overall Sheath |
PVC, FR-PVC, PE or LSOH |
Technical data
Rated voltage: 1.8/3kV, 6/10kV, 8.7/10kV, 8.7/15kV, 12/20kV, 21/35kV, 26/35kV
Max. Conductor Temp.: normal (90°C), short circuit no more than 5 s (160°C when section-area below 300mm2, 140°C when section-area above 300mm2)
Min. Ambient Temp.:The cable shall be pre heated if the ambient temperature is below 0°C
Min. Bending Radius: single core cable 20(d+D)±5%
Multi-core cable 15(d+D)±5%
MV(6 to 35kv) Power Cable | |||
Model and Description | No.of Core | Conductor cross-section area(mm2) | |
xlpe insulation | 1 3 | 10 16 25 35 70 95 120 150 185 240 300 400 500 630 800 1000 | |
Cu core | Al Core | ||
YJV;PVC sheathed power cable | YJLV;PVC sheathed power cable | ||
YJV22;steel tape armoured,PVC sheathed power cable | YJLV22;steel tape armoured,PVC sheathed power cable | ||
YJV32,YJV42;steel wire armoured ,PVC sheathed power cable | YJLV32,YJLV42;steel wire armoured ,PVC sheathed power cable | ||
pvc insulation | |||
Cu Core | Al Core | ||
VV(VY);PVC(PE)sheathed power cable | VLV(VLY);PVC(PE)sheathed power cable | ||
VV22(VV23);steel tape armoured,PVC(PE)sheathed power cable | VLV22(VLV23);steel tape armoured,PVC(PE)sheathed power cable | ||
VV32(VV33),VV42(VV43);steel wire armoured ,PVC(PE)sheathed power cable | VLV32(VLV33),VLV42(VLV43);steel wire armoured ,PVC(PE)sheathed power cable |
Certificates
CE, RoHS, CCC, KEMA and more others at request
International: IEC 60502, IEC 60228
China: GB/T 12706.1-2008
Other standards such as BS,DIN and ICEA upon request
4 Table of the voltage, cores and cross-section
Item |
Category A ,B |
3.6/6kV |
6/10kV |
8.7/15kV |
12/20kV |
18/30kV |
21/35kV |
Category A ,B |
6/6kV |
8.7/10kV |
12/15kV |
18/20kV |
– |
26/35kV |
|
Single core |
mm2 |
25-1200 |
25-1200 |
35-1200 |
50-1200 |
50-1200 |
50-1200 |
Three core |
mm2 |
25-400 |
25-400 |
35-400 |
50-400 |
50-400 |
50-400 |
The cable with Category A rated voltage is used in the situation requiring not over 1 min. of grounding fault lasting time. For the cable with Category B rated voltage, the grounding fault lasting time normally is not over 1 hour, max. lasting time is not over 8 hours, annual ground fault lasting time altogether should not be over 125 hours, Category C includes all the system expect Category A and B.