PVC sheath lv power cable Swa Cable Prices

PVC sheath  lv power cable Swa Cable Prices
Port: qingdao,shanghai,tianjin
Payment Terms: L/C,T/T
Supply Ability: 100 Kilometer/Kilometers per Month xlpe cable
Place of Origin: Henan China
Brand Name: ZMS Cable/OEM
Model Number: HD-ZA- YJV32
Insulation Material: XLPE
Type: Low Voltage
Application: Construction
Conductor Material: Copper
Jacket: PVC
Product Name: LV Cable
Rated Voltage: 600/1000V (0.6/1kV)
Dimensions: 1.5,2.5,4,6,10,16,25,35,50,70,95,120,150,185,240,300,400mm2
No. of Cores: 1,2,3,4,5
Conductor: Stranded round compacted copper or aluminum conductor (Cu/Al)
Sheath: PVC (Polyvinyl Chloride), flame retardant PVC, PE, LSOH, HFFR
Standards: IEC 60502
Insulation: XLPE
Certificate: ISO9001
Packaging Detail: Wooden Drum or As Your Request for LV Cable
hot cable

Related Products

 

0.6/1kv ABC twist cable aac aaac acsr  ARMORED CABLE 
HIGH VOLTAGE SCREENED ABC  4 core 95mm2 abc  concentirc aluminum conductor cable transmission

 

 

Application

Distribution power cable for static application, mostly in ground, but also in water, within facilities, in cable canals, in concrete. Used in electric power plants, transformer stations, industrial plants, metropolitan networks and other electric plants. Applied in conditions requiring protection against heavier mechanical damages, but where cables are not exposed to heavier tensile strain.

 

Standard

HRN HD 603 S1

IEC 60502-1

DIN VDE 0276 part 603

cables with 6 and more conductors:

HRN HD 627 S1

DIN VDE 027

 

Construction

Conductor:Cu, class 1 or 2 acc. to HRN HD 383 / IEC 60228 / DIN VDE 0295

class 1:solid, round (RE)

class 2:multi wire stranded, round (RM) or sector (SM), multi wire exceeding 50 mm² are compacted

Insulation:PVC compound, concentrically stranded cores, colour marked acc. to HRN HD 308 S2 / VDE 0293-308, with or without protective yellow-green conductor

Filler:spouted elastomer or plastomer compound or wrapped thermoplastic tapes

Armour:dtwo galvanized steel tapes

Sheath:PVC compound

sheath colour:black

 

Technical data

Temperature range: 

during installation:-5 °C up to +50 °C

fixed installed:-30 °C up to +70 °C

at short circuit of max. 5 s:up to 160 °C

Nominal voltage:Uο/U = 0,6/1 kV

Test voltage:4 kV

Maximal tensile strength:50 N/mm²

Behaviour in fire:IEC 60332-1

Minimal inner bending radius: 

single core:15D

multi core:12D

 

Special version upon request

 

Cross sectional area customized

Aluminum conductor required

 

Advantages

Excellent electric and mechanical characteristics

Best Resistance chemical corrosion and heat-ageing,environment stress and flame-retardant

Simple in structure,Convenient to use

Reduce costs

Dimensions and Weights

 

number of cores x conductor cross-section Construction Construction of individual conductor Insulation thickness Sheath thickness External diameter Cable weight
N x mm²   N x mm mm mm mm Kg/km
Power NYBY-J, NYBY-O
2 x 4 RE 1 x 2,2 1 1,8 15,3 420
2 x 6 RE 1 x 2,7 1 1,8 16,3 493
2 x 10 RM 7 x 1,34 1 1,8 18,7 668
2 x 16 RM 7 x 1,70 1 1,8 20,9 873
3 x 4 RE 1 x 2,2 1 1,8 16 476
3 x 6 RE 1 x 2,7 1 1,8 17,1 569
3 x 10 RM 7 x 1,34 1 1,8 19,7 783
3 x 16 RM 7 x 1,70 1 1,8 22,1 1044
3 x 16+10 RM/RE 7 x 1,7/7 x 1,3 1,0 / 1,0 1,8 23,2 1163
3 x 25+16 RM/RM 7 x 2,2/7 x 1,7 1,2 / 1,0 1,8 26,2 1641
3 x 35+16 SM/RM 7 x 2,5/7 x 1,7 1,2 / 1,0 1,8 28,2 1978
3 x 50+25 SM/RM 7 x 3,/7 x 2,2 1,4 / 1,2 1,9 31,9 2606
3 x 70+35 SM/RM 13 x 2,7/7 x 2,5 1,4 / 1,2 2 35,8 3471
3 x 95+50 SM/RM 17 x 2,7/7 x 3 1,6 / 1,4 2,2 42,6 4963
4 x 1,5 RE 1 x 1,37 0,8 1,8 14,2 357
4 x 2,5 RE 1 x 1,74 0,8 1,8 15,1 424
4 x 4 RE 1 x 2,2 1 1,8 17,1 555
4 x 6 RE 1 x 2,7 1 1,8 18,3 670
4 x 10 RM 7 x 1,34 1 1,8 21,2 936
4 x 16 RM 7 x 1,70 1 1,8 23,8 1265
4 x 25 RM 7 x 2,20 1,2 1,8 27 1793
5 x 4 RE 1 x 2,2 1 1,8 18,3 640
5 x 16 RM 7 x 1,70 1 1,8 25,8 1472
5 x 50 SM 7 x 3,00 1,4 2,1 37 3498
5 x 70 SM 13 x 2,70 1,4 2,2 42,6 4956
5 x 95 SM 17 x 2,70 1,6 2,4 50 6748
5 x 120 SM 18 x 3,00 1,6 2,6 53,1 7941

 