power cable copper wire screen power cable

power cable copper wire screen power cable
Port: Qingdao Shanghai
Payment Terms: L/C,T/T
Supply Ability: 1500000 Meter/Meters per Day
Place of Origin: Christmas Island
Brand Name: ZMS
Model Number: YJV32
Insulation Material: XLPE
Type: Medium Voltage
Application: Construction
Conductor Material: Copper
Jacket: PE
No. of Cores: 1C, 2C, 3C, 3C+1C, 3C+2C, 4C, 4C+1C, 5C
Application: power plants, Industrial, distribution lines,
Dimensions: 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70,95, 120, 150, 185, 240, 300,400
Conductor: Stranded round compacted copper or aluminum conductor (Cu / Al )
Armoring Type: SWA, AWA, STA, DSTA, GSWA
Sheath: PVC (Polyvinyl Chloride), flame retardant PVC, PE, LSOH, HFFR
Color: Black
Operating Temperature: 0°C to 90°C
Standards: IEC60502-1, BS6346, BS5467, BS6360, BS6724, VDE0276, etc.
Packaging Detail: wooden drums or according your require
PRODUCT DESCRIPTION

 

APPLICATIONS:

The cables are designed for distribution of electrical power with nominal voltage Uo/U 19/33KV and frequency 50Hz. It is used to transmit and distribute power in power transmission and distribution system of 33kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.

STANDARD:

BS 6622

BS 7835 (LSZH Version)

CONSTRUCTION:

Conductor: Plain annealed copper or aluminium complying with IEC 60228/BS 6360. Copper

conductors shall be stranded and aluminium conductors shall be either solid or

stranded.

Conductor Screen: Extruded layer of semi-conducting cross-linkable compound is applied

over the conductor and shall cover the surface completely. The minimum thickness is 0.3mm

and the maximum resistivity shall not exceed 500 Ohm-m at 90°C.

Insulation: Insulation is of cross-linked polyethylene compound XLPE (GP8) conforming to

BS 7655-1.3 or EPR (GP7), conforming to BS 7655-1.2.

TABLE 1. INSULATION THICKNESS:

Nom. Cross Section Area Insulation Thickness at Nom. Voltage
19/33KV(Um=36KV)
mm² mm
70 – 185 8.0
240 8.0
300 8.0
400 8.0
Above 500 8.0

Insulaton Screen: Extruded layer of semi-conducting cross-linkable compound is applied

over the insulation. The extruded semi-conducting layer shall consist of bonded or cold

strippable semi-conducting compound capable of removal for jointing or terminating. As an

option, a semi-conducting tape may be applied over the extruded semi-conducting layer as a

bedding for the metallic layer. The minimum thickness is 0.3 mm and the maximum resistivity

is 500 Ohm-m at 90°C. The screen is tightly fitted to the insulation to exclude all air voids and

can be easily hand stripped on site.

Inner Covering; Fillers: For cables with a collective metallic layer or cables with a metallic

layer over each individual cores with additional collective metallic layers, semi-conducting

inner covering and fillers shall be applied over the laid up cores. The inner covering is made

of non hygroscopic material, except if the cable is to be made longitudinally watertight. The

inner covering shall be extruded or lapped.

The approximate thickness of extruded inner coverings is given in Table 2:

TABLE 2. APPROXIMATE THICKNESS OF EXTRUDED INNER COVERINGS

Ficititous Diameter over Laid Up Cores; Approx. Thickness of Extruded Inner Covering;
mm; mm
>; <;  
25 1.0
25 35 1.2
35 45 1.4
45 60 1.6
60 80 1.8
80 2.0

Metallic Layer: The metallic layer shall be applied over each core or applied as a collective

screen. The metallic screen shall consist of either copper tapes or a concentric layer of

copper wires or a combination of tapes and wires. The metallic layer provides an earth

fault current path, capable of withstanding fault current to earth of 1000A for one second at

maximum temperature 160°C. Copper wires are applied over the conducting water blocking

layer with a minimum diameter of 0.5mm. And over the copper wires, copper tape with

minimum thickness of 0.1mm can be applied helically with overlap.

Total cross section of copper wire screen is shown in table 3.

TABLE 3. MINIMUM TOTAL CROSS SECTION OF COPPER WIRE SCREEN; DC RESISTANCE OF THE SCREEN

Nominal Cross-Section Area of Cable Minimum Cross-Section of Copper Wire Screen Area DC Resistance of the Copper Wire Screen
mm² mm² mm
up to;120 16 1.06
150-300 25 0.72
400-630 35 0.51

Separation Sheath (for armoured cable): The separation sheath comprises a layer of extruded PVC, PE or LSZH. The nominal thickness is calculated by 0.02Du + 0.6mm where Du is the fictitious diameter under the sheath in mm. The nominal separation sheath thickness

shall not be less than 1.2mm.

Armour (for armoured cable): The armour consists of galvanized steel wire applied over the

inner covering with diameter specified as in Table 4.

TABLE 4. ARMOUR WIRE DIAMETER

Fictitiious Diameter under the Armour Armour Wire Diameter
mm mm
> <  
25 1.6
25 35 2.0
35 60 2.5
60 3.15

Over Sheath: Overall sheath comprises a layer of extruded either PVC type 9 conforming

to BS 7665-4.2 or MDPE type TS2 conforming to BS 7655-10.1; LSZH can be offered as an

option. The over sheath is normally black in colour. When a DC voltage test is to be performed on the over sheath, a semi-conducting layer such as graphite coating shall be applied over the surface of the extruded over sheath. The nominal over sheath thickness is calculated by 0.035D+1 where D is the diameter immediately under the over sheath in mm. For cables with the over sheath not applied over the armour, the nominal over sheath thickness shall not be less than 1.4mm. And for cables with over sheath applied over the armour, the nominal over sheath thickness shall not be less than 1.8mm.

PHYSICAL PROPERTIES:

Operating Temperature: up to 90°C

Temperature Range: -5°C ( PVC or LSZH sheath ); -20°C ( PE sheath )

Short Circuit Temperature: 250°C (short circuit duration up to 5 seconds)

Bending Radius: 12 x OD

DIMENSIONAL DATA:

Nom. Cross- Section 
Area
Nom. Insulation 
Thickness
Copper Tape 
Screen Area
Nom.Bedding 
Thickness
Nom. Armour 
Wire Diameter
Nom.Sheath 
Thickness
Approx. Overall 
Diameter
Approx. Weight
CU AL
mm² mm mm² mm mm mm mm kg/km
50 8.0 6.7 1.8 3.15 3.4 79.0 10620 9680
70 8.0 7.1 1.8 3.15 3.5 82.5 11840 10440
95 8.0 7.5 1.9 3.15 3.6 86.4 13200 11350
120 8.0 7.9 2.0 3.15 3.7 89.9 14520 12190
150 8.0 8.2 2.0 3.15 3.8 93.6 16070 13280
185 8.0 8.6 2.1 3.15 3.9 97.3 17710 14090
240 8.0 9.2 2.2 3.15 4.1 103.2 20370 15460
300 8.0 9.7 2.3 3.15 4.3 108.2 22980 17210
400 8.0 10.3 2.4 3.15 4.5 116.8 27480 19450
HOT PRODUCTS

OUR COMPANY

 

PRODUCTS TESTING

 

OUR CERTIFICATIONS

 

FAQ

  • Q: Is your company a factory or trading company?
    A: We are factory with our own trading company. Our trade business expands home and abroad.
  • Q: When can I get the price?
    A:We usually quote within 12 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your e-mail so that we will regard your inquiry priority.
  • Q: How can I get a sample to check your quality?
    A: After price confirmation, you can require for samples to check our quality. Sample is free, but the freight charge should be paid.
  • Q: What is Minimum Order Quantity?
    A: Generally, 1000 meters for building wire. For power cable, armored or unarmored, 500 meters.
  • Q: Which standards for your products?
    A: We can produce wire and cable according to international standards: IEC, ASTM, BS, DIN, SANS, CSA or as customers’ requirement.
  • Q: How about delivery time?
    A: If we have stock, delivery would be very quick. For the newly-produced products, 15 to 25 days for production.
  • Q: Payment terms:
    A: Normally 30% paid as prepayment, balance paid before delivery. Or 100% L/C at sight
  • Q: What is your packing?
    A: Our electrical cable is using electrical cable wheel for the packing, the wheel can be all steel, steel frame and fumigated wood, or fumigated wooden cases. We are using different packing for different length of the cable, to ensure there will be no problem during the delivery of the products.
Tags: , ,

Contact us

 

 

 

Search