Popular Heat-resistant Nylon Coating Electric wire THHN THWN-2 TW THW T90 AWG8 AWG10 AWG12 AWG16

Popular Heat-resistant Nylon Coating Electric wire THHN THWN-2 TW THW T90 AWG8 AWG10 AWG12 AWG16
Port: QINGDAO
Payment Terms: L/C,T/T,Western Union,MoneyGram
Supply Ability: 10000 Meter/Meters per Day
Place of Origin: Henan China
Brand Name: ZMS or OEM
Model Number: THWN-2 TW THW T90 AWG8 AWG10 AWG12 AWG14 AWG16
Type: Insulated
Application: building
Conductor Material: Copper
Conductor Type: solid or stranded
Insulation Material: PVC
Rated Voltage: 600V
sizes: AWG8 AWG10 AWG12 AWG14 AWG16
Sheath: nylon
color: Black, White, Blue, Red, Yellow, Green, Orange
Delivery Detail: 15 DAYS for THHN THWN-2 TW THW T90 electric wire
Packaging Detail: export standard drum FROM ZMS CABLE

 Popular Heat-resistant Nylon Coating Electric  Wire THHN THWN-2 TW THW T90 AWG8 AWG10 AWG12 AWG16

 

 

1. Application:

 

THHN stands for "thermoplastic, heat-resistant nylon coating". THHN is the name of a particular insulation material, temperature rating, and service condition (suitable for dry and wet locations) for electric wires and cables.They cables are commonly used in AC power distribution systems and are typically rated 110V to 600V. 

 

General purpose wiring in accordance with the National Electrical Code, maximum conductor temperature of 90°C in dry locations , 600 volts.THHN cable may also be used for wiring of machine tools, control circuits or on certain appliances.

 

Temperature rating not to exceed:

 

THHN/THWN: 90°C dry and dump, 600V

 

THHN/THWN: 75 °C wet or in oil, 600V

 

THWN-2: 90°C Dry, wet or in oil,600V   

 

 2. Construction:

 

 Conductor: Annealed Copper, solid or stranded sizes 14AWG up to 1000MCM

 

Insulation: Premium Grade Flame Retardant Polyvinyl Chloride( PVC)

 

Jacket: Tough Polyamide (Nylon)

 

3. Standard&Test Specification:

 

Underwriters Laboratories Standard 83 for Thermoplastic Insulated Wires.

Underwriters Laboratories Standard 1063 for Machine-Tool Wires and Cables (Stranded items only) 

Underwriters Laboratories Standard 758 for 105°C Appliance Wiring Materials (Stranded items only).

CSA Standard C22.2 No. 75 and Electrical Bulletin No. 1451 for Type T90 Nylon or TWN75.

Federal Specification J-C-30B.

 

4. Colors available

Available colors: Black, White, Blue, Red, Yellow, Green, Orange and according to customer's request.

 

5. Dimensions of THHN wire

Size NO. of 
Strands
Nominal Insulation thickness Nominal 
Jacket thickness
OD of Nominal cable Weight of 
the Nominal cable
    Inch mm Inch mm Inch mm Lbs/kft kg/km
AWG                  
14 Solid 0.015 0.38 0.004 0.1 0.11 2.79 15 22
12 Solid 0.015 0.38 0.004 0.1 0.12 3.05 23 34
10 Solid 0.02 0.51 0.004 0.1 0.15 3.81 37 54
14 19 0.015 0.38 0.004 0.1 0.11 2.79 16 24
12 19 0.015 0.38 0.004 0.1 0.13 3.3 24 36
10 19 0.02 0.51 0.004 0.1 0.17 4.32 39 58
8 19 0.03 0.76 0.005 0.13 0.22 5.59 63 94
6 19 0.03 0.76 0.005 0.13 0.26 6.6 98 145
4 19 0.04 1.01 0.006 0.15 0.33 8.38 157 234
3 19 0.04 1.01 0.006 0.15 0.36 9.14 193 287
2 19 0.04 1.01 0.006 0.15 0.39 9.91 240 357
1 19 0.05 1.27 0.007 0.18 0.43 10.92 300 446
1/0 19 0.05 1.27 0.007 0.18 0.47 11.94 376 560
2/0 19 0.05 1.27 0.007 0.18 0.52 13.21 467 695
3/0 19 0.05 1.27 0.007 0.18 0.57 14.48 581 864
4/0 19 0.05 1.27 0.007 0.18 0.64 16.26 724 1077

 

Our Services

Related Products

 

33kv armored types of underground cables AWA12/20kV single core underground cable Medium voltage 3 core cables 70mm
Factory price high quality ZMS supply PVC insulation PVC sheath 3 core armoured copper electric cables Overhead transmission line aac aaac acsr conductor 35mm aluminum abc power cable Overhead line conductor AAC AAAC ACSR fast cables price list
Product Overviews

 

Certifications

Established Year: 1990
Factory Area: 50000 SQ.MM
Manufacturing Capacity Each Year: 250,000 KM
Number of Employees: 100-150
Sales Revenue (2013): US $ 27.89million
Certificates: ISO9001:2008, CCC, CE, SONCAP

 

 

 

FAQ

FAQ

  • Q: Is your company a factory or trading company?
    A: We are factory with our own trading company. Our trade business expands home and abroad.
  • Q: When can I get the price?
    A:We usually quote within 12 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your e-mail so that we will regard your inquiry priority.
  • Q: How can I get a sample to check your quality?
    A: After price confirmation, you can require for samples to check our quality. Sample is free, but the freight charge should be paid.
  • Q: What is Minimum Order Quantity?
    A: Generally, 1000 meters for building wire. For power cable, armored or unarmored, 500 meters.
  • Q: Which standards for your products?
    A: We can produce wire and cable according to international standards: IEC, ASTM, BS, DIN, SANS, CSA or as customers’ requirement.
  • Q: How about delivery time?
    A: If we have stock, delivery would be very quick. For the newly-produced products, 15 to 25 days for production.
  • Q: Payment terms:
    A: Normally 30% paid as prepayment, balance paid before delivery. Or 100% L/C at sight
  • Q: What is your packing?
    A: Our electrical cable is using electrical cable wheel for the packing, the wheel can be all steel, steel frame and fumigated wood, or fumigated wooden cases. We are using different packing for different length of the cable, to ensure there will be no problem during the delivery of the products.