Overhead aerial bundled cable 3X35+54.6+16 sq mm2 ABC cable

Overhead aerial bundled cable 3X35+54.6+16 sq mm2 ABC cable
Port: Tianjin
Payment Terms: L/C,T/T,Western Union
Supply Ability: 5000 Kilometer/Kilometers per Month abc cable
Place of Origin: Hebei China
Brand Name: HAOHUA
Model Number: abc cable
Insulation Material: XLPE
Type: Low Voltage
Application: Overhead
Conductor Material: Aluminum
Jacket: None
Certificate: TUV, ISO900, ISO14001, ISO18001
Color: as customer requirement
Conductor Type: Stranded
Company nature: Manufactury for abc cable
Standard: ASTM ICEA NFC
Delivery Detail: Within 20 working days after receiving the down payment
Packaging Detail: abc cable should be supplied in steel/wooden drum.

Overhead aerial bundled cable 3X35+54.6+16 sq mm2 ABC cable

Application

abc cable is used to supply 3 phase power, usually from a pole- mounted transformer, to the user's service head where connect to the service entrance cable. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for PE insulated Conductors or 90°C for crosslinked polyethylene (XLPE) insulated conductors.

 

 

Standards of abc cable

International: IEC 60502, IEC 60228

China: GB/T 14049-93

Other standards such as BS,DIN and ICEA upon request 

 

Description of ABC cable

 1. Material: Aluminium, copper

2. Type: LJ, LGJ, LGJF, JL, JLHA, JL/G, JLHA/G, JL/LHA, JL/LB, JLHA/LB, JG, JLB.

3. Rated Voltage: 0./1 kV, 10kV, 35kV. 

4. No. of cores: 1, 2, 3, 4, 3+k(A), 3+k(B). 

5. Standard: GB/T12527  GB/T14049 or other.

6. Insulation: PVC, PE, xlpe

7. Sheath:PVC, PE, XLPE

8. Application: applying in cable fixed aerial laying or used as wire leading into user's premises.

 

 

 

 Model and Specification of  abc cable

 

4

5

6

7

8

9

10

NAME

 

CONDUCTOR

 

Nominal insulation Thickness

Cable

 

Type

 

Nominal Cross-section of conductor

 

Core No.

 

Max.resistance

Conductor Dia.

 

Tensile strength

 

Overall Dia.

 

 

 

(mm2)

 

20°C

(Ω/km)

Max.

(mm)

Min.

(mm)

Min.

(daN)

 

(mm)

Min. (mm)

Max.

(mm)

Phase wire/ Non-sling neuter line/ Light cores

 

16

25

35

 

50

70

95

120

150

7

7

7

 

7

12

19

19

19

1.9l

1.20

0.868

 

0.641

0.443

0.320

0.253

0.206

4.6

5.8

6.8

 

7.9

9.7

11.0

12.0

13.9

5.1

6.3

7.3

 

8.4

10.2

12.0

13.1

15.0

190

300

 

1.2

1.4

1.6

 

1.6

1.8

1.8

1.8

1.7

7.0

8.6

10.0

 

11.1

13.3

14.6

15.6

17.3

7.8

9.4

lO.g

 

12.0

14.2

15.7

16.7

18.6

sling neuter line

54.6

70

95

7

7

19

0.63

0.50

0.343

9.2

10.0

12.2

9.6

10.2

12.9

1660

2050

2750

1.6

1.5

1.6

12.3

12.9

15.3**

13.0

13.6

16.3**

Testing wire

1.5

1

12.1

1.5

1.2

3.7

4.2

w 35kV Steel  

Packaging & Shipping

Packing :  abc cable should be supplied in steel/wooden drum. Cable piece length should be of 500meter length or as specified by the customer at the time of order.

Shipping : Within 15 working days  after confirming the detailed information for  abc cable

 

 

 