NFC33-209 ICEA,IEC Standard Aluminum Conductor XLPE Insulated Aerial Bounded Cable 2x10mm2 2x16mm2 4x10mm2 4x16

NFC33-209 ICEA,IEC Standard Aluminum Conductor XLPE Insulated Aerial Bounded Cable 2x10mm2 2x16mm2 4x10mm2 4x16
Port: Qingdao
Payment Terms: L/C,T/T
Supply Ability: 15 Twenty-Foot Container per Month
Place of Origin: Henan China
Brand Name: JINSHUI or OEM
Model Number: mm2 AWG
Insulation Material: XLPE
Type: Low Voltage
Application: Construction
Conductor Material: Aluminum
Conductor: Aluminum
Delivery Detail: Based on type and requirements
Packaging Detail: 100% drum 100% steel drum Soft coils for small size(500mts/coil)

ASTM Standard ( Duplex,Triplex, Quadruplex)

 

A.Duplex Service Drop

 

Application
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75°C maximum.

Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC/AAAC/ACSR  neutral messenger.

 

 

Code*Word Phase conductor Bare Neutral Message Nominal lay Length Weight Per
1000 ft.(lbs.)
Allo wable Amp acitles
Size
(A WG)
Stranding Insul
Thick(Mils)
Size
(AWG)
Stranding Rated
Strength
(lbs.)
inches XLP POLY XLP POLY
AAC Neutral-messenger
Pekingese 6 1 45 6 7 563 10.36 61 61 85 70
Collie 6 7 45 6 7 563 10.36 64 64 85 70
Dachshund 4 1 45 4 7 881 10.36 92 92 115 90
Spaniel 4 7 45 4 7 881 10.36 96 96 115 90
Doberman 2 7 45 2 7 1350 14.88 147 147 150 120
Malemute 1/0 9 60 1/0 7 1990 14.88 234 234 205 160

 

 B.Triplex Service Drop

 

Application
To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volts or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene Insulation or 90°C maximum for crosslinked insulation.

Construction
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC/AAAC/ACSR neutral messenger.

 

 

Code*Word Phase conductor Bare Neutral Message Nominal lay Length Weight Per
1000 ft.(lbs.)
Allo wable Amp acitles
Size
(A WG)
Stranding Insul
Thick(Mils)
Size
(AWG)
Stranding Rated
Strength
(lbs.)
inches XLP POLY XLP POLY
AAC Neutral-messenger
Pateela 6 7 45 6 7 563 14.88 103 103 85 70
Oyster 4 7 45 4 7 881 14.88 154 154 115 90
Clam 2 7 45 2 7 1350 20.58 233 233 150 120
Murex 1/0 7 60 1/0 7 1990 20.58 374 374 205 160
Purpura 1/0 9 60 1/0 7 1990 20.58 368 368 205 160
Nassa 2/0 7 60 2/0 7 2510 25.42 462 462 235 185
Melita 3/0 17 60 3/0 19 3310 29.97 562 562 275 215
Portunus 4/0 18 60 4/0 19 4020 29.97 696 696 315 245
Nannynose 336.4 19 60 336.4 19 6146 38.79 1118 1118 420 325
 

 

 C. Quadruplex Service Drop

 

Application
Used to supply 3 phase power, usually from a pole- mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.

Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded AAC/AAAC/ACSR. One conductor is manufactured with an extruded ridge for phase identification.

 

 

Code*Word Phase conductor Bare Neutral Message Nominal lay Length Weight Per
1000 ft.(lbs.)
Allo wable Amp acitles
Size
(A WG)
Stranding Insul
Thick(Mils)
Size
(AWG)
Stranding Rated
Strength
(lbs.)
inches XLP POLY XLP POLY
AAC Neutral-messenger
Clydessdale 4 1 45 4 7 881 20.58 198 198 100 80
Pinto 4 7 45 4 7 881 20.58 211 211 100 80
Mustang 2 7 45 2 7 1350 25.42 318 318 135 105
Criollo 1/0 9 60 1/0 7 1990 25.42 503 503 180 140
Percheron 2/0 11 60 2/0 7 2510 29.97 619 619 205 160
Hanovarian 3/0 17 60 3/0 19 3310 35.18 764 764 235 185
Oldenburg 4/0 18 60 4/0 19 4020 35.18 945 945 275 210
Lippizaner 336.4 19 80 336.4 19 6146 38.79 1519 1519 370 280
 

 

Our advantage:

 

1. 12 years experience as professional manufacture of ABC cable.

2. Strict and complete test procedure to ensure the quality.

3. Quick delivery time.

4. More competitive price in this field.

5. Abundant experience for exporting, SGS inspection, taking in a bid.

 

Welcome to visit our company & factory!

 

 

 

 

 