NFC 33209 ABC aluminum cable Twisted pre-assembled insulated cable 2*16 4*16

Port: | QINGDAO SHANGHAI GUANGZHOU |
Payment Terms: | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
Supply Ability: | 1800 Kilometer/Kilometers per Month |
Place of Origin: | henan |
Brand Name: | hongda |
Model Number: | ABC |
Insulation Material: | XLPE |
Type: | Low Voltage |
Application: | Overhead |
Conductor Material: | AAC |
Jacket: | NO jacekt |
Color: | as Clients'request |
Certification: | ISO9001 CQC |
Product name: | ABC |
Material: | ALUMINUM |
Voltage: | 600V 1000V |
standard: | NFC 33209 |
SUPPORT: | aster 54.6 |
Packaging Detail: | in coil |
Application:
Aerial Bundle Cable (ABC cable) has characters of power-transmitting and strong mechanical. In comparison with bare wire, aerial bundle cable (ABC cable) boasts many advantages, such as:small span in laying, higher safe reliability, better atmosphere aging resistence property. Aerial bundle cable has the priority to be used in urban and rural power-transmitting construction project.
Insulation: PVC or XLPE PVC
ABC aerial bundle cable withAluminium stranded conductor(compacted or non- compacted), AAAC or ACSR messenger core.
Aluminium stranded conductor(compacted or non- compacted), AAAC messenger core(or ACSR messenger core), XLPE(or HDPE) insulated, Twisted (or Parallel)power cable
The product is a new type of aerial cable for power transmitting, It is extensively used in overhead power transmission line, It improves the safety and reliance of electrified wire netting.
Using features
Long-term working max. temperature is not more than:
aerial cable with PVC or PE insulation:70℃
aerial cable with XLPE insultion:90℃
Short circuit(sustained the longest time is not more than 5s),Max. temperature of conductor is no more than:
aerial cable with PVC insulation:160℃
aerial cable with PE insulation:130℃
aerial cable with XLPE insultion:250℃
enviroment temperature is not less than -20℃ when laying
Bending radius of cable:
it is not less than 4 times of the outer diameter when the outer diameter(D) is less than 25mm
when using AC system,the rated voltage of cables should be equal to the rated voltage of system at least:
when using DC system,the rated voltage of system should be not more than 1.5 times of the rated voltage
Number of Cores x Nominal Cross Section | Outer Diameter | Total Weight | Max. Conductor- Resistance | Min. Breaking Load of Conductor Strand | Current Rating in the Air |
---|---|---|---|---|---|
mm^2 | ca. mm | ca. kg/km | Ohm/km | kN | A |
2x 16 RM | 15.6 | 147 | 1.910 | 2.5 | 72 |
2x 25 RM | 18.0 | 208 | 1.200 | 4.0 | 107 |
2x 35 RM | 20.0 | 277 | 0.868 | 5.5 | 132 |
2x 50 RM | 23.5 | 361 | 0.641 | 8.0 | 165 |
4x 16 RM | 18.8 | 286 | 1.910 | 2.5 | 72 |
4x 25 RM | 21.2 | 430 | 1.200 | 4.0 | 107 |
4x 35 RM | 24.1 | 553 | 0.868 | 5.5 | 132 |
4x 50 RM | 27.8 | 746 | 0.641 | 8.0 | 165 |
4x 70 RM | 31.8 | 1009 | 0.443 | 10.7 | 205 |
4x 95 RM | 37.8 | 1332 | 0.320 | 13.7 | 240 |
4x 120 RM | 54.4 | 1632 | 0.253 | 18.6 | 290 |
Number of Cores x Nominal Cross Section | Overal Diameter | Weight | Maximum Conductor Resistance | Minimum Breaking Load | Current Rating |
---|---|---|---|---|---|
No.×mm^2 | mm | Kg/Km | Ω/Km | KN | A |
4×10 RM | 15.4 | 183 | 3.080 | 1.5 | 38 |
2×16 RM | 14.8 | 129 | 1.910 | 2.3 | 72 |
4×16 RM | 17.8 | 257 | 1.910 | 2.3 | 72 |
4×16 RN + 2×1.5 RE | 17.8 | 304 | 1.910/12.100 | 2.3 | 72 |
2×25 RM | 18.0 | 202 | 1.200 | 3.8 | 107 |
2×25 RM + 2×1.5 RE | 18.0 | 249 | 1.200/12.100 | 3.8 | 107 |
4×25 RM | 21.7 | 404 | 1.200 | 3.8 | 107 |
4×25 RM + 2×1.5 RE | 21.7 | 451 | 1.200/12.100 | 3.8 | 107 |
2×35 RM | 20.8 | 269 | 0.868 | 5.2 | 132 |
2×35 RM + 2×1.5 RE | 20.8 | 316 | 0.868/12.100 | 5.2 | 132 |
4×35 RM | 25.1 | 539 | 0.868 | 5.2 | 132 |
4×35 RM + 2×1.5 RE | 25.1 | 586 | 0.868/12.100 | 5.2 | 132 |
2×50 RM + 2×1.5 RE | 23.4 | 399 | 0.641/12.100 | 7.6 | 165 |
1×54.6 RM + 3×25 RM | 21.7 | 507 | 0.630/1.200 | 3.8 | 107 |
1×54.6 RM + 3×25 RM + 1×16 RM | 24.3 | 573 | 0.630/1.200/1.910 | 3.8/2.3 | 107/72 |
1×54.6 RM + 3×25 RM + 2×16 RM | 29.7 | 639 | 0.630/1.200/1.910 | 3.8/2.3 | 107/72 |
1×54.6 RM + 3×25 RM + 3×16 RM | 31.1 | 705 | 0.630/1.200/1.910 | 3.8/2.3 | 107/72 |
1×54.6 RM + 3×35 RM | 25.1 | 615 | 0.630/0.868 | 5.2 | 132 |
1×54.6 RM + 3×35 RM + 1×16 RM | 28.1 | 680 | 0.630/0.868/1.910 | 5.2/2.3 | 132/72 |
1×54.6 RM + 3×35 RM + 2×16 RM | 34.3 | 748 | 0.630/0.868/1.910 | 5.2/2.3 | 132/72 |
1×54.6 RM + 3×35 RM + 3×16 RM | 35.9 | 814 | 0.630/0.868/1.910 | 5.2/2.3 | 132/72 |
1×54.6 RM + 3×35 RM + 1×25 RM | 28.1 | 714 | 0.630/0.868/1.200 | 5.2/3.8 | 132/107 |
1×54.6 RM + 3×50 RM | 28.2 | 741 | 0.630/0.641 | 7.6 | 165 |
1×54.6 RM + 3×50 RM + 1×16 RM | 31.6 | 806 | 0.630/0.641/1.910 | 7.6/2.3 | 165/72 |
1×54.6 RM + 3×50 RM + 2×16 RM | 38.6 | 875 | 0.630/0.641/1.910 | 7.6/2.3 | 165/72 |
1×54.6 RM + 3×50 RM + 3×16 RM | 40.4 | 940 | 0.630/0.641/1.910 | 7.6/2.3 | 165/72 |
1×54.6 RM + 3×50 RM + 1×25 RM | 31.6 | 841 | 0.630/0.641/1.200 | 7.6/3.8 | 165/107 |
1×54.6 RM + 3×70 RM | 33.0 | 950 | 0.630/0.443 | 10.2 | 205 |
1×54.6 RM + 3×70 RM + 1×16 RM | 37.0 | 1014 | 0.630/0.443/1.910 | 10.2/2.3 | 205/72 |
1×54.6 RM + 3×70 RM + 2×16 RM | 45.2 | 1083 | 0.630/0.443/1.910 | 10.2/2.3 | 205/72 |
1×54.6 RM + 3×70 RM + 3×16 RM | 47.3 | 1148 | 0.630/0.443/1.910 | 10.2/2.3 | 205/72 |
1×54.6 RM + 3×70 RM + 1×25 RM | 37.0 | 1048 | 0.630/0.443/1.200 | 10.2/3.8 | 205/107 |
1×54.6 RM + 3×70 RM + 2×25 RM | 45.2 | 110 | 0.630/0.443/1.200 | 10.2/3.8 | 205/107 |
1×54.6 RM + 3×70 RM + 3×25 RM | 47.3 | 1250 | 0.630/0.443/1.200 | 10.2/3.8 | 205/107 |
1×54.6 RM + 3×95 RM | 37.4 | 1176 | 0.630/0.320 | 13.5 | 240 |
1×54.6 RM + 3×95 RM + 1×16 RM | 41.9 | 1243 | 0.630/0.320/1.910 | 13.5/2.3 | 240/72 |
Other cross-sections can be offered upon request.