N2XS2Y CU/XLPE/PVC MV Power Cable VDE Standard

N2XS2Y CU/XLPE/PVC MV Power Cable VDE Standard
Port: Shanghai Port
Payment Terms: L/C,T/T
Supply Ability: 3000000 Meter/Meters per Month
Place of Origin: Shanghai China
Brand Name: Xinxin
Model Number: N2XS2Y/YJY Power Cable
Insulation Material: XLPE
Type: Medium Voltage
Application: Underground
Conductor Material: Copper
Jacket: PE
Packaging Detail: XLPE Power cable Wooden Drum.

Copper core, XLPE insulated, PE sheath

N2XS2Y CABLE 

Cable structure

  • Circular bare copper core, stranded according to HD 383, IEC 60228
  • Inner semi-conducting coating
  • Core insulation of cross-linked polyethylene (XLPE)
  • Insulation thickness: 6/10 kV = 3,4 mm; 12/20 kV = 5,5 mm; 18/30 kV = 8,0 mm
  • Outer semi-conducting coating spliced with the insulation
  • Tape of conductive material
  • Screening of copper wires and one or two copper tapes contrary applied
  • Wrapping with non-conducting tape
  • Sheath of PE compound, color black, sheath thickness 2,5 mm

Technical data

  • XLPE-insulated cable according to DIN VDE 0276 part 620, HD 620 and IEC 60502
  • Temperature range max. +90 °C during installation from -5 °C to +70 °C Short circuit temperature 250 °C (up to 5 seconds)
  • Nominal voltages Uo/U 6/10 kV, 12/20 kV, 18/30 kV
  • Operating voltages for 6/10 kV = max. 12 kV; 12/20 kV = max. 24 kV; 18/30 kV = max. 36 kV
  • Test voltage a.c. for 6/10 kV = 21 kV up to 5 min. 12/20 kV = 42 kV up to 5 min. 18/30 kV = 63 kV up to 5 min.
  • Minimum bending radius approx. 15 x cable diameter

Application

Cable suitable for installation in cable ducts, power plants as well as for outer laying into earth, water or for installation in distribution boards. Due to its good shaping characteristics, this cable can also be laid even in difficult line guideways. To avoid the influence of the outer interferences, an adherent semiconductive layer is extruded between the conductor and the insulation. We recommend the use of stripping tool for correct installation.

N2XS2Y  6/10 kV

Ordering code Number of cores × core cross section [mm2] Approx. outer ø min.[mm] Approx. outer ø max.[mm] Cooper weight [kg/km] Approx. cable weight [kg/km]
0932480 1 × 35 rm/16 23 28 518 900
0932481 1 × 50 rm/16 24 29 662 950
0932482 1 × 70 rm/16 26 31 860 1200
0932483 1 × 95 rm/16 27 32 1098 1450
0932484 1 × 120 rm/16 29 34 1340 1700
0932485 1 × 150 rm/16* 30 35 1622 1950
0932486 1 × 150 rm/25 30 35 1725 2050
0932487 1 × 185 rm/16* 32 37 1958 2350
0932488 1 × 185 rm/25 32 37 2059 2400
0932489 1 × 240 rm/16* 34 39 2486 2900
0932490 1 × 240 rm/25 34 39 2587 2950
0932491 1 × 300 rm/25 36 41 3163 3550
0932492 1 × 400 rm/35 40 45 4234 4500
0932493 1 × 500 rm/35 43 48 5194 5500

N2XS2Y  12/20 kV

Ordering code Number of cores × core cross section [mm2] Approx. outer ø min.[mm] Approx. outer ø max.[mm] Cooper weight [kg/km] Approx. cable weight [kg/km]
0932494 1 × 35 rm/16 27 32 518 1150
0932495 1 × 50 rm/16 28 33 662 1300
0932496 1 × 70 rm/16 30 35 854 1350
0932497 1 × 95 rm/16 31 36 1094 1650
0932498 1 × 120 rm/16 33 38 1334 1900
0932499 1 × 150 rm/16* 54 39 1622 2150
0932500 1 × 150 rm/25 34 39 1723 2250
0932501 1 × 185 rm/16* 36 41 1958 2550
0932502 1 × 185 rm/25 36 41 2059 2600
0932503 1 × 240 rm/16* 39 44 2486 3100
0932504 1 × 240 rm/25 39 44 2587 3200
0932505 1 × 300 rm/25 41 46 3163 3800
0932506 1 × 400 rm/35 44 49 4234 4750
0932507 1 × 500 rm/35 47 52 5194 5800

N2XS2Y  18/30 kV

Ordering code Number of cores × core cross section [mm2] Approx. outer ø min.[mm] Approx. outer ø max.[mm] Cooper weight [kg/km] Approx. cable weight [kg/km]
0932508 1 × 50 rm/16 33 38 662 1350
0932509 1 × 70 rm/16 35 40 854 1600
0932510 1 × 95 rm/16 36 41 1094 1900
0932511 1 × 120 rm/16 38 43 1334 2150
0932512 1 × 150 rm/25 39 44 1723 2550
0932513 1 × 185 rm/25 41 46 2059 2900
0932514 1 × 240 rm/25 43 48 2587 3500
0932515 1 × 300 rm/25 46 51 3163 4150
0932516 1 × 400 rm/35 49 54 4234 5100
0932517 1 × 500 rm/35 52 57 5194 6200

 

 

 

 

 

 

 