Instrumentation Cable
For use in installations designed to connect electrical instrumentation circuits and provide communication services in and around process plants. Suitable for direct burial applications.
Specification of instrument cable:

Instrument Cable Conductors:

0.5mm – class 5 flexible copper

0.75mm – class 5 flexible copper

1.5mm – class 2 stranded copper

Insulation: PE (Polyethylene)

Screen: CAM (Collective Aluminium Mylar)

Bedding: PE (Polyethylene)

Armour: SWA

Outer Sheath: PVC (Polyvinyl-Chloride)

Voltage Rating: 300/500volts

Temp. Rating: 65 C

Flexible  instrumentation multi-core cables about PVC insulated and twisted parallel cable

 

 

Standard: National Standard GB/T 5023; IEC60227

Rated Voltage: 300/300V;

 Construction: 1. annealed flexible copper conductor

                       2.PVC insulated 

 Application: used for electric appliance, electric tool, electric instruments and lighting, automatic system 

Application of insulated cable Instrument Cable :
It is used to transmit and distribute power on the power line of A. C. Rated voltage 0.6/1kV.

XLPE insulated electric cable Instrument Cable 0.6/1kv
norminalsectional area  insulati-on thicknes sheath thickness(mm) overal diameter of cable (mm) D.C resistance of conductor(km)                 current rating
in air(A) direct in soil(A)
cu Al cu Al cu Al
1×1.5 0.7 1.5 6 <=12.1 <=12.1 30 25 45 35
1×4 0.7 1.5 7 <=7.41 <=7.41 45 35 60 50
1×6 0.7 1.5 7 <=3.08 <=4.61 55 45 70 55
1×35 0.9 1.5 12 <=0.524 <=0.868 175 140 190 150
1×50 1 1.5 13 <=0.387 <=0.641 210 170 225 180
1×70

1

.1

1.5 14 <=0.268 <=0.443 270 215 280 225
1×95 1.1 1.5 16 <=0.193 <=0.320 340 275 335 270
1×120 1.2 1.5 18 <=0.153 <=0.253 400 320 380 305
1×150 1.4 2 21 <=0.124 <=0.206 460 370 425 340
1×185 1.6 2 23 <=0.0991 <=0.164 530 415 480 375
1×240 1.7 2 25 <=0.0754 <=0.125 625 490 555 435
                 
3×1.5 0.7 1.5 10 <=12.1 <=12.1 25 25 30 30
3×2.5 0.7 1.5 11 <=7.41 <=12.1 30 25 35 30
3×4 0.7 1.5 12 <=4.61 <=7.41 40 30 50 40
               
Attention: We can provide more info than above data, if needed.The above are just some examples.

 

Using features of insulated cable Instrument Cable :
1. Rated voltage: Uo/U: 0.6/1kV
2. No. Of core: Single-core, Two-core, Three-core, Four-core, Five-core, Three core and earth(Three primary conductor and one Neutral conductor), Three core and two((Three primary conductor and Two Neutral conductor), Four core and earth((Four primary conductor and One Neutral conductor).
3. The highest allowed operating temperature of conductor for long-term working is 70oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 160oC.
4. D. C. Resistance of the conductor complies with the stipulations of GB/T3956-1997.
5. The environment temperature should be no lower than 0oC when lay. Otherwise it should be preheated.

Model: insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable

 