Multi-Pair multi-core Shielded flame retardant SWA Instrument Cable 1.5mm 2.5mm

Multi-Pair multi-core Shielded flame retardant SWA Instrument Cable  1.5mm   2.5mm
Port: qingdao shanghai
Payment Terms: L/C,T/T,Western Union,MoneyGram
Supply Ability: 1000 Kilometer/Kilometers per Week good quality on Instrument Cable
Place of Origin: Henan China
Brand Name: hongda
Model Number: SWA instrument cable
Shielding: Combination
Conductor Material: Copper
Jacket: PVC
Insulation Material: XLPE
Model: SWA Instrument Cable
Type: armored xlpe cable
model2: insulated Instrument Cable
Packaging Detail: coil or according to your require

Multi-Pair multi-core Shielded flame retardant SWA Instrument Cable  1.5mm   2.5mm 

 

Copper Conductor 4 x 2.5mm2 PVC Pair Instrument Signal Cable

pvc insulated cable

Standard of insulated cable:
It is manufacture under GB/T12706-2002 standard(The same as IEC60502).

 

UP TO 600/1000V PE INSULATION INSTRUMENTATION CABLE 
Generally to IEC Standard No.: BS 5308-1978 
Maximum working temperature 70° C 
PE or PVC/Multi-pair/ Collectively screened/Unarmoured/PVC 
PE or PVC/Multi-pair/ Individually & Collectively screened/Unarmoured/PVC 
PE or PVC/Multi-pair/ Collectively screened/Galvanized steel wire armoured/PVC 
PE or PVC/Multi-pair/ Individually & Collectively screened/ Galvanized steel wire armoured/PVC 
PE or PVC/Multi-pair/ Collectively screened/Galvanized steel wire braiding/PVC 
PE or PVC/Multi-pair/ Individually & Collectively screened/ Galvanized steel wire braiding/PVC

 

Instrument Cable Application:

For use in installations designed to connect electrical instrumentation circuits and provide communication services in and around process plants. Suitable for direct burial applications.

Specification of instrument cable:

Instrument Cable Conductors:

0.5mm – class 5 flexible copper

0.75mm – class 5 flexible copper

1.5mm – class 2 stranded copper

Insulation: PE (Polyethylene)

Screen: CAM (Collective Aluminium Mylar)

Bedding: PE (Polyethylene)

Armour: SWA

Outer Sheath: PVC (Polyvinyl-Chloride)

Voltage Rating: 300/500volts

Temp. Rating: 65 C

Flexible  instrumentation multi-core cables about PVC insulated and twisted parallel cable

 

 

Standard: National Standard GB/T 5023; IEC60227

Rated Voltage: 300/300V;

 Construction: 1. annealed flexible copper conductor

                       2.PVC insulated 

 Application: used for electric appliance, electric tool, electric instruments and lighting, automatic system 

Application of insulated cable Instrument Cable :
It is used to transmit and distribute power on the power line of A. C. Rated voltage 0.6/1kV.

XLPE insulated electric cable Instrument Cable 0.6/1kv
norminalsectional area  insulati-on thicknes sheath thickness(mm) overal diameter of cable (mm) D.C resistance of conductor(km)                 current rating
in air(A) direct in soil(A)
cu Al cu Al cu Al
1×1.5 0.7 1.5 6 <=12.1 <=12.1 30 25 45 35
1×4 0.7 1.5 7 <=7.41 <=7.41 45 35 60 50
1×6 0.7 1.5 7 <=3.08 <=4.61 55 45 70 55
1×35 0.9 1.5 12 <=0.524 <=0.868 175 140 190 150
1×50 1 1.5 13 <=0.387 <=0.641 210 170 225 180
1×70

1

.1

1.5 14 <=0.268 <=0.443 270 215 280 225
1×95 1.1 1.5 16 <=0.193 <=0.320 340 275 335 270
1×120 1.2 1.5 18 <=0.153 <=0.253 400 320 380 305
1×150 1.4 2 21 <=0.124 <=0.206 460 370 425 340
1×185 1.6 2 23 <=0.0991 <=0.164 530 415 480 375
1×240 1.7 2 25 <=0.0754 <=0.125 625 490 555 435
                 
3×1.5 0.7 1.5 10 <=12.1 <=12.1 25 25 30 30
3×2.5 0.7 1.5 11 <=7.41 <=12.1 30 25 35 30
3×4 0.7 1.5 12 <=4.61 <=7.41 40 30 50 40
               
Attention: We can provide more info than above data, if needed.The above are just some examples.

 

Using features of insulated cable Instrument Cable :
1. Rated voltage: Uo/U: 0.6/1kV
2. No. Of core: Single-core, Two-core, Three-core, Four-core, Five-core, Three core and earth(Three primary conductor and one Neutral conductor), Three core and two((Three primary conductor and Two Neutral conductor), Four core and earth((Four primary conductor and One Neutral conductor).
3. The highest allowed operating temperature of conductor for long-term working is 70oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 160oC.
4. D. C. Resistance of the conductor complies with the stipulations of GB/T3956-1997.
5. The environment temperature should be no lower than 0oC when lay. Otherwise it should be preheated.

Model: insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable

 

welcome to inquire us  Instrument Cable

contact information

Contact information

 

Any needs or question ,please contact us ,we will be more pleasure to service you.

 

We are looking forward to your inquiry and nice cooperaton.

 

 

Tags: , ,

Contact us

 

 

 

Search

You May Like

  • No related articles