Multi core screened armoured control cable

Port: | Qingdao or as request |
Payment Terms: | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
Supply Ability: | 500000 Meter/Meters per Month screened armoured control cable |
Place of Origin: | Henan China |
Brand Name: | San Heng |
Model Number: | RVVP |
Insulation Material: | PVC |
Type: | Low Voltage |
Application: | Construction |
Conductor Material: | Copper |
Jacket: | PVC |
Description: | screened armoured control cable |
Color: | Black White Red |
Standard: | GB/T12706-2002 IEC60502-1994 |
Voltage: | 300/500V |
Company nature: | Manufacturer |
Certification: | CCC/CE/ISO |
Company Location: | Zhengzhou |
Packaging Detail: | 100m/roll |
Multi core screened armoured control cable
Application:
The control cable are suitable for the wiring of electrical controlling equipments and instrument,monitoring and controlling return circuit,
electrical protection and measurement in power distribution unit under the circumstance that the rated voltage is up to 450/750V AC.Characteristics
1,Maximum operation voltage: 600 V.
2,Maximum operation temperature in the conductor:
90°C In a dry environment.
75°C In a wet environment.
3,Soft drawn concentric lay stranded copper conductor class B (7 wires).
4,Manufactured in sizes from 0,823 5 to 5,26 mm2 (18 to 10 AWG).
5,No-flame propagation characteristics.
6,Polyvinyl Chloride (PVC) insulation and jacket with low smoke emission and low acid gas content characteristics.
Black outer jacket.
7,No existen especificaciones técnicas para este producto.
8,Con. Multiple-cond. THW-LS / THHW-LS Con. Multiple-cond. THWN / THHN Con. PE + PVC type
Control EPR + CPE Type Control EPR + PVC Type Control XLPE + PVC
Control Zero Halogens LS PVC + PVC type LS PVC + PVC type / shielded cables
9,LS tipo PVC + PVC / interlock armor industrial plants and to connect safety and signaling devices, where characteristics such as no- flame propagation,
low smoke emission and low acid gas content are required
10,Can be installed in trays or conduits and in underground or exposed to sunlight facilities, in wet or dry locations.
Technical Data:
1) Conductors have three species: First (Solid conductor) (A), Second for fixed installation
(B) (Stranded conductor), and Third for moveable requirement (R) (stranded flexible conductor).
2) The structure and D. C. resistance.
3) The screen layer of cables shall be braided with copper wire or applied helically with copper tape.
Dimensions – number of cores x conductor cross-section |
External diameter |
Cu weight | Cable weight |
approx. | approx. | ||
N x mm² | mm | kg/km | kg/km |
2 x 0,5 | 5,3 | 32 | 45 |
3 x 0,5 | 5,6 | 39 | 55 |
4 x 0,5 | 6,3 | 46 | 61 |
5 x 0,5 | 6,6 | 52 | 74 |
6 x 0,5 | 7,2 | 66 | 89 |
7 x 0,5 | 7,6 | 68 | 98 |
8 x 0,5 | 8,3 | 80 | 117 |
10 x 0,5 | 9 | 81 | 135 |
12 x 0,5 | 9,5 | 117 | 157 |
2 x 0,75 | 6,2 | 39 | 59 |
3 x 0,75 | 6,2 | 49 | 66 |
4 x 0,75 | 6,7 | 57 | 77 |
5 x 0,75 | 7,4 | 70 | 93 |
6 x 0,75 | 8 | 78 | 113 |
7 x 0,75 | 8,6 | 98 | 130 |
8 x 0,75 | 9,2 | 16 | 145 |
10 x 0,75 | 10,3 | 140 | 180 |
12 x 0,75 | 10,7 | 151 | 202 |
2 x 1 | 6,7 | 55 | 65 |
3 x 1 | 7 | 70 | 80 |
4 x 1 | 7,1 | 80 | 98 |
5 x 1 | 8,5 | 95 | 127 |
6 x 1 | 9,1 | 105 | 144 |
7 x 1 | 9,7 | 120 | 158 |
8 x 1 | 11 | 130 | 197 |
10 x 1 | 12 | 138 | 232 |
12 x 1 | 12,4 | 186 | 260 |
2 x 1,5 | 7,3 | 65 | 88 |
3 x 1,5 | 7,7 | 90 | 100 |
4 x 1,5 | 8,3 | 110 | 126 |
5 x 1,5 | 9,4 | 125 | 160 |
7 x 1,5 | 10,7 | 159 | 208 |
8 x 1,5 | 12 | 172 | 244 |
10 x 1,5 | 13,4 | 193 | 315 |
12 x 1,5 | 13,6 | 254 | 338 |
2 x 2,5 | 9 | 98 | 130 |
3 x 2,5 | 9,9 | 148 | 167 |
4 x 2,5 | 10,2 | 174 | 195 |
5 x 2,5 | 11,6 | 200 | 223 |
7 x 2,5 | 13,7 | 235 | 344 |
10 x 2,5 | 15,8 | 335 | 460 |
- Next: 50 Core 2.5mm2 Cable PVC Insulated KVV Control Cable
- Previous: pvc coated super flex wire 2 core 0.5mm electric copper wire flat cable RVB