LV XLPE insulated copper cable 4x95sqmm

Port: | Qingdao |
Payment Terms: | L/C,D/A,D/P,T/T |
Supply Ability: | 2000 Kilometer/Kilometers per Month |
Place of Origin: | Henan China |
Brand Name: | Jinshui |
Insulation Material: | XLPE |
Type: | Medium Voltage |
Application: | Underground |
Conductor Material: | Copper or Aluminum |
Jacket: | PVC or PE |
Nominal Sectional Area: | 1.5-1000mm2 |
Number of Core: | 1-5 cores |
Armour: | STA or SWA |
Rated Voltage: | 1-35KV |
Standard: | IEC 60502 |
Certificates: | ISO9001, CE, CCC |
Packaging Detail: | Export all wooden drum, steel-wooden drum, all steel drum as customer's requests |
Application:
It is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.
Construction:
Conductor: Copper (or Aluminium)
Insulation: XLPE
Filler: Non-hygroscopic Polypropylene(PP)
Binder Tape: Non-woven fabric
Inner Covering: PVC
Metallic Armour: Galvanized Steel Wire Armour(SWA)
Non-magnetic Steel Wire Armour(only for single core)
Aluminium Wire Armoured(AWA, only for single core)
Outer Sheath: PVC (or PE)
Standards:
The products are mainly complying with IEC 60502 standard, also can be produced according to OEM requirements and other standards, such as BS standard, DIN standard, ASTM standard, etc.
Voltage grade is up to 35kv, cross-section area can be up to 400 sqmm (copper or alumimum conductor). Conductor long-time operating temperature is 90°C. In short circuit, conductor highest temperature should be not more than 250°C
Using features:
1. Rated voltage: Uo/U: 26/35kV, 21/35kV, 12/20 kV (24 kV), 8.7/10kV, 8.7/15kV, 6/6kV, 6/10kV.
2. No. of core: Single-core, Three-core.
3. The highest allowed operating temperature of conductor for long-term working is 90°C. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250°C.
4. D.C Resistance of the conductor complies with the stipulations of GB/T3956-1997.
5. The environment temperature should be no lower than 0°C when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit. The Min. Bending radius of three-core cable should be no smaller than 12 times of cable outer diameter.
7. Working Frequency Voltage Test:.
For cable with Uo of 3.6kV or lower: 2.5Uo+2kV/5min without puncture.
For cable with Uo of 3.6Kv~18kV: 3.5Uo/5min without puncture.
For cable with Uo of 21kV and 26 kV: 2.5Uo/30min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.
Type |
Description |
Number of cores |
Nominal cross section of conductor |
YJV32 |
CU/XLPE/SWA/PVC Power Cable |
1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm2 |
YJLV32 |
AL/XLPE/SWA/PVC Power Cable |
||
YJV72 |
CU/XLPE/Non-magnetic SWA or AWA/PVC Power Cable |
1 |
1.5~1000mm2 |
YJLV72 |
AL/XLPE/Non-magnetic SWA or AWA/PVC Power Cable |
||
YJV33 |
CU/XLPE/SWA/PE Power Cable |
1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm2 |
YJLV33 |
AL/XLPE/SWA/PE Power Cable |
||
Z-YJV32 |
CU/XLPE/SWA Flame-retardant Power Cable |
1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm2 |
Z-YJLV32 |
AL/XLPE/SWA Flame-retardant Power Cable |
||
WDZ-YJY33 |
CU/XLPE/SWA Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) Flame-retardant Power Cable |
1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm2 |
WDZ-YJLY33 |
AL/XLPE/SWA Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) Flame-retardant Power Cable |
||
N-YJV32 |
CU/XLPE/SWA Fire-resistant Power Cable |
1, 2, 3, 4, 3+1, 5, 4+1, 3+2 |
1.5~1000mm2 |
Type |
Name |
Application |
|
Cu conducto |
Al Conductor |
||
YJV |
YJLV |
XLPE insulated, PVC or PE sheathed power cable |
For laying indoor, tunnel, channel and underground. Unable to bear external mechanical force during laid. |
YJY |
YJLV |
||
YJV22 |
YJLV22 |
XLPE insulated, steel tape armoured, PVC or PE sheathed power cable |
For laying indoor, tunnel, channel and underground. Able to bear external mechanical force, but unable to bear large pulling force. |
YJV23 |
YJLY23 |
||
YJV32 |
YJLV32 |
XLPE insulated, fine steel wire armoured, PVC or PE sheathed power cable |
For laying in shaft with large difference of level. Able to bear external mechanical force ,and moderate pulling force. |
YJV42 |
YJLV42 |
XLPE insulated, thick steel armoured, PVC or PE sheathed power cable |
For laying in shaft with large difference of level. Able to bear external mechanical force ,and moderate pulling force. |
1. Are you the factory or trading company?
We are the manufacturer and 13 years gold supplier on alibaba.We are engaged in exporting cables for nearly 15 years.
2. When can I get the price?
We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your e-mail so that we will regard your inquiry priority.
3. How can I get a sample to check your quality?
After price confirmation, you can require for samples to check our quality. Sample is free, but the freightcharge should be paid.
4. What is the payment terms?
30% deposit by T/T,70% T/T after checking the copy of B/L. Or irrevocable L/C at sight .
5. What about the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.
- Next: 8.7/15KV XLPE insulation medium voltage armored power cable
- Previous: Electric THHN wire 12AWG 600V
Contact us
Search
You May Like