LV/MV/HV XLPE Insulated Steel Wire Armored Copper Electric Power Cable 1x400 mm 3x240 mm

LV/MV/HV XLPE Insulated Steel Wire Armored Copper Electric Power Cable 1x400 mm 3x240 mm
Port: Shanghai
Payment Terms: L/C,T/T
Supply Ability: 10000 Meter/Meters per Day
Place of Origin: Shanghai China
Brand Name: SHAN OEM
Model Number: CU/XLPE/PVC/SWA/PVC POWER CABLE
Insulation Material: XLPE
Type: Medium Voltage
Application: Power Station
Conductor Material: Copper
Jacket: PVC
Certificates: KEMA, CE, RoHS, CCC
Standard: IEC 60502 IEC60228
Warranty: 2 years since delivery
Delivery Detail: 10-15 days
Packaging Detail: Wooden Drum

LV/MV/HV XLPE Insulated Steel Wire Armored Copper Electric Power Cable 1×400 mm 3×240 mm

 

Description:

CU/XLPE/STA/PVC, IEC 60502

IEC 60502, IEC 60228GB/T 12706.1-2008.

CE, CCC, KEMA

 

Constructions

Conductor: Circular stranded copper conductor, conforms to IEC 60228 class 2

Insulation: XLPE/A

Inner Covering: PVC

Armour: Galvanized Steel Wire or tape 

Sheath: PVC type ST2 to IEC 60502, black

Note: Insulation color as per standards or customer requirement

 

Conductor

Compact Stranded Copper Conductor, Class 2 as per IEC 60228

Circular solid Copper Conductor, Class 1 as per IEC 60228

Flexible Stranded Copper Conductor, Class 5 as per IEC 60228

Conductor Screen

Semi-conductor (MV only)

Insulation

XLPE(Cross-linked polyethylene)

Insulation Screen

Semi-conductor (MV only)

Metalic Shield

Copper Tape Screen or Copper wire & copper tape Shield (MV must, LV optional)

Filler

Fillers strip

Wrapping Tape

Non woven wrapping tape or lsoh wrapping tape

Inner Covering

Extruded PVC, or LSOH (MV only)

Armour

Steel Tape Armour, Steel Wire or Aluminium Wire Armor optional

Overall Sheath

PVC, FR-PVC, PE or LSOH

 

   

Applications

Used for Power transmission and distribution line with voltage rated at 35kv and below. Compared with PVC Insulated Power cable, XLPE power cable boasts not only characteristics of excellent electricity, mechanism , heat and aging- resistant, environment stress-resistant and chemical corrosion resistant, but also simple structure, light weight, no restriction by laying drop, and high temperature allowance for long term working.

For Layling indoors and outdoors. Able to bear certain traction during installation, but not external mechanical forces. Standards

  

Technical data

Rated voltage: 2-35 kV 0.6/1kV, 1.8/3kV, 6/10kV, 8.7/10kV, 8.7/15kV, 12/20kV, 21/35kV, 26/35kV

 

 

Maximum Conductor Temperature: under normal (90°C), emergency (130°C) or short circuit no more than 5 s (250°C) conditions.

Min. Ambient Temp. 0°C, after installation and only when cable is in a fixed position

Min. Bending Radius: 20 x cable O.D for single-core non-armoured cables

                                15 x cable O.D for single-core armoured cables

                                15 x cable O.D for multi-core non-armoured cables

                                12 x cable O.D for multi-core armoured cables

 

 

 

Certificates

CE, RoHS, CCC, KEMA and more others at request

International: IEC 60502, IEC 60228

China: GB/T 12706.1-2008

 

Other standards such as BS,DIN and ICEA upon request 

 

4 Table of the voltage, cores and cross-section

Item

Category    A ,B

3.6/6kV

6/10kV

8.7/15kV

12/20kV

18/30kV

21/35kV

Category    A ,B

6/6kV

8.7/10kV

12/15kV

18/20kV

        –

26/35kV

Single core

           mm2

25-1200

25-1200

35-1200

50-1200

50-1200

50-1200

Three core

           mm2

25-400

25-400

35-400

50-400

50-400

50-400

 

The cable with Category A rated voltage is used in the situation requiring not over 1 min. of grounding fault lasting time. For the cable with Category B rated voltage, the grounding fault lasting time normally is not over 1 hour, max. lasting time is not over 8 hours, annual ground fault lasting time altogether should not be over 125 hours, Category C includes all the system expect Category A and B.

 

 

 

 

 

 