LV MV HV ABC Cable

LV MV HV ABC Cable
Port: Qingdao or Shanghai Any port in China
Payment Terms: L/C,T/T,Western Union
Supply Ability: 300 Kilometer/Kilometers per Month
Place of Origin: Henan China
Brand Name: Jinshui
Model Number: ABC CABLE
Insulation Material: PE/XLPE
Type: 0.6/1 kv
Application: Overhead
Conductor Material: Aluminum
Jacket: PVC
Certificate: ISO,CE,BV,ROHS .
Packaging Detail: Standard export wooden drums or as your requirement

Specifications

 RATED VOLTAGE 0.6/1KV / ALUMINwIUM CONDUCTOR OR ALUMINIUM ALLOY CONDUCTOR/ sPVC OR PE OR XLPE INSULATION AERIAL BUNDLE CABLES 

Aerial Busndled Cables : RATED VOLTAGE 0.6/1KV /  ALUMINwIUM CONDUCTOR OR ALUMINIUM ALLOY CONDUCTOR/  sPVC OR PE OR XLPE INSULATION AERIAL BUNDLE CABLES.

 

DESCRIPTION
The aerial bundle cables designed for overhead distribution lines have an insulated neutral 
rnessenger
rnade of AAAC, which the insulated alurniniurn phase conductors are helically wound over it. Cables 
are rated at 0.6/1(1.2) kV and conforrn to IEC 60502
The rnain advantages of aerial bundle cables include :
1. Ease of erection and stringing
2. Practically no tree – trirnrning required
3. Less rnaintenance 

 

1   Phase conductor :
 The phase conductors shall be of H68 Condition aluminium conductor and compacted circular 
stranded.

2   Messenger conductor :
The neutral messenger conductor shall be of aluminium alloy conductor and compacted circular 
stranded.

3   Street Lighting conductor :
The street lighting conductors shall be of H68 Condition aluminium conductor and compacted circular 
stranded.

4   Insulation :
The phase, messenger and street lighting conductors shall be extruded with Polyethylene ( PE ) as 
insulation.

5   The Completed Cable
The cable consists of insulated phase and  street lighting aluminium conductors, shall be held 
firmly onto the 
insulated neutral messenger aluminium alloy conductor in a right-hand ( Z ) direction of lay.

Cond. Size Maximum Diameter Thickness of insulation Approx. Diameter Approx. Weight DC resistance Permissible current D Min.breaking strength
Phase core Neutral core Phase core Neutral core Phase core Neutral core Phase core Neutral core
mm2 mm mm mm mm mm Kg/km /km /km A kN kN
2×50 + 50 8,4                  9,5 1,5                1,5 26 590 0,641                0,65 150 7,0                16,6
3×50 + 50 8,4                  9,5 1,5                1,5 29 785 0,641                0,65 150 7,0                16,6
3×70 + 50 10,1                9,5 1,5                1,5 32 895 0,443                0,65 185 9,8                16,6
3×95 + 70 11,9                10,7 1,7                1,5 36 1210 0,320               0,508 225 13,3               20,5
3×120 + 70 13,5                10,7 1,7                1,5 38 1430 0,253               0,508 260 16,8               20,5
3×150 + 70 14,9                10,7 1,7                1,5 41 1665 0,206               0,508 285 21,0               20,5

 

Cond. Size No. of core Maximum Diameter Number of wire Thickness of insulation Approx. mass DC Resistance at 20C Min. Breaking strength
Conductor Insulated core Cable dia.
mm2   mm mm mm No. mm Kg/km ohm/km kN
10 2
3
4
3,75 6,6 13.2
14.3
16
7 13 215
325
430
183 7,4
11,1
14,8
16 2
3
4
4,65 7,5 15
16.2
18.2
7 13 325
490
655
115 12,0
18,0
24,0
25 2
3
4
5,9 8,7 17.4
18.8
21.1
7 13 500
750
995
727 18,8
28,2
37,6
35 2
3
4
7,0 9,8 19.6
21.2
23.7
7 13 675
1015
1355
524 26,4
39,6
52,8

 

 