LSZH Sheath Mica Tape Fire Resistant Cable 2.5mm
Port: | Qingdao |
Payment Terms: | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
Supply Ability: | 600 Kilometer/Kilometers per Month |
Place of Origin: | Henan China |
Brand Name: | Hongda |
Model Number: | fire resistant cable |
Type: | Insulated |
Application: | Heating |
Conductor Material: | Copper |
Conductor Type: | Stranded or solid |
Insulation Material: | LSZH |
Product name: | LSZH Sheath Mica Tape Fire Resistant Cable 2.5mm |
Conductor: | Pure Copper |
Insulation: | LSZH |
Rated Voltage: | 450/750V |
Color: | Red Black Yellow Green White |
Standard: | BS 7211 |
Certification: | ISO9001 |
Material: | Copper and LSOH |
Size: | 1.5mm 2.5mm 4mm 6mm 10mm 16mm |
Packing: | 100m/roll or as your request |
Packaging Detail: | 100 meters/roll |
Get more information connect with
Tina
Mobile: +86 157 3715 6317 (WhatsApp / Wechat)
Email: tina@ hdcable.com.cn
APPLICATION
This cable is used in fire extinguishing systems, sprinklers, control panels, and exit lights in high-rise buildings, hotels, hospitals,sub-ways,and public acilities.
STANDARDS
- Basic design to BS 7211
FIRE PERFORMANCE
Circuit Integrity | IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180); CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1) |
System circuit integrity | DIN 4102-12, E30 depending on lay system |
Flame Retardance (Single Vertical Wire Test) | EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*;DIN VDE 0482-265-2-1* |
Reduced Fire Propagation (Vertically-mounted bundled wires &cable test) | EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Halogen Free | IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1; BS 6425-1* |
No Corrosive Gas Emission | IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2; BS 6425-2* |
Minimum Smoke Emission | IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
No Toxic gases | NES 02-713; NF C 20-454 |
Note: Asterisk * denotes superseded standard.
VOLTAGE RATING
450/750V & 600/1000V
CABLE CONSTRUCTION
Conductor | Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2 |
Fire Barrier | Mica glass tape |
Insulation | Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option |
COLOUR CODE
Insulation Colour: Black (other colors upon request)
PHYSICAL AND THERMAL PROPERTIES
Temperature range during operation (fixed state) | -30°C – +90°C |
Temperature range during installation (mobile state) | -20°C – +50°C |
Minimum bending radius | 6 x Overall Diameter |
ELECTRICAL PROPERTIES
Dielectric test | 600/1000V: 3500 V r.m.s. x 5’(core/core); 450/750V: 2500 V r.m.s. x 5’(core/core) |
Insulation resistance | 20 MΩ x km (at 20°C) |
Short circuit temperature | 250°C |
CONSTRUCTION PARAMETERS
Conductor | FFX100 07mZ1-R | FFX100 1mZ1-R | |||||
---|---|---|---|---|---|---|---|
Nominal Cross Section Area | No./Nominal Diameter of Strands | Nominal Insulation Thickness | Nominal Overall Diameter | Approx. Weight | Nominal Insulation Thickness | Nominal Overall Diameter | Approx. Weight |
mm2 | No./mm | mm | mm | kg/km | mm | mm | kg/km |
1.5 | 7/0.53 | 0.7 | 3.5 | 25 | 0.8 | 3.8 | 30 |
2.5 | 7/0.67 | 0.8 | 4.1 | 35 | 0.8 | 4.2 | 40 |
4 | 7/0.85 | 0.8 | 4.6 | 52 | 1 | 5.3 | 70 |
6 | 7/1.04 | 0.8 | 5.2 | 72 | 1 | 6 | 96 |
10 | 7/1.35 | 1 | 6.5 | 120 | 1 | 6.6 | 130 |
16 | 7/1.70 | 1 | 7.6 | 180 | 1 | 7.7 | 200 |
25 | 7/2.14 | 1.2 | 9 | 275 | 1.2 | 9.1 | 290 |
35 | 7/2.52 | 1.2 | 10.2 | 370 | 1.2 | 10.3 | 390 |
50 | 19/2.52 | 1.4 | 11.8 | 500 | 1.4 | 11.9 | 520 |
70 | 19/2.14 | 1.4 | 13.4 | 700 | 1.4 | 13.5 | 730 |
95 | 19.2.52 | 1.6 | 15.8 | 980 | 1.6 | 15.9 | 990 |
150 | 37/2.52 | 1.8 | 18.8 | 1500 | 1.8 | 18.9 | 1520 |
185 | 37/2.52 | 2 | 21 | 1900 | 2 | 21.2 | 1900 |
240 | 37/2.52 | 2.2 | 25.7 | 2500 | 2.2 | 25.8 | 2550 |
300 | 37/2.52 | 2.4 | 28.6 | 3140 | 2.4 | 28.8 | 3150 |
400 | 61/2.85 | 2.6 | 32 | 4000 | 2.6 | 32.2 | 4000 |
500 | 61/3.20 | 2.8 | 35.5 | 5000 | 2.8 | 35.7 | 5000 |
630 | 127/2.52 | 2.8 | 39.5 | 6300 | 2.8 | 39.7 | 6360 |
ELECTRICAL PROPERTIES
Conductor Operating Temperature | 90°C |
Ambient Temperature | 30°C |
Current-Carrying Capacities (Amp)
Conductor cross-sectional area | Reference Method A (enclosed in conduit in thermally insulating wall etc) | Reference Method B (enclosed in conduit on a wall or intrunking etc) | Reference Method C (clipped direct) | Reference Method F (in free air or on a perforated cable tray, horizontal orvertical etc) Touching | Reference Method G (in free air) Spaced by one cable diameter | |||||
---|---|---|---|---|---|---|---|---|---|---|
2 cables, single-phase a.c. or d.c. | 3 or 4 cables, three-phase a.c. | 2 cables, single-phase a.c. or d.c | 3 or 4 cables, three-phase a.c. | 2 cables, single-phase a.c. or d.c. flat and touching | 3 or 4 cables, three-phase a.c. flat and touching or trefoil | 2 cables,single-phase a.c. or d.c. flat | 3 cables, three-phase a.c. flat | 3 cables, three-phase a.c. trefoil | 2 cables, single-phase a.c. or d.c. or 3 cables three-phase a.c. flat | |
Vertical | ||||||||||
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 12 |
mm2 | A | A | A | A | A | A | A | A | A | A |
1.5 | 19 | 17 | 23 | 20 | 25 | 23 | – | – | – | – |
2.5 | 26 | 23 | 31 | 28 | 34 | 31 | – | – | – | – |
4 | 35 | 31 | 42 | 37 | 46 | 41 | – | – | – | – |
6 | 45 | 40 | 54 | 48 | 59 | 54 | – | – | – | – |
10 | 61 | 54 | 75 | 66 | 81 | 74 | – | – | – | – |
16 | 81 | 73 | 100 | 88 | 109 | 99 | – | – | – | – |
25 | 106 | 95 | 133 | 117 | 143 | 130 | 161 | 141 | 135 | 161 |
35 | 131 | 117 | 164 | 144 | 176 | 161 | 200 | 176 | 169 | 201 |
50 | 158 | 141 | 198 | 175 | 228 | 209 | 242 | 216 | 207 | 246 |
70 | 200 | 179 | 253 | 222 | 293 | 268 | 310 | 279 | 268 | 318 |
95 | 241 | 216 | 306 | 269 | 355 | 326 | 377 | 342 | 328 | 389 |
120 | 278 | 249 | 354 | 312 | 413 | 379 | 437 | 400 | 383 | 454 |
150 | 318 | 285 | 393 | 342 | 476 | 436 | 504 | 464 | 444 | 527 |
185 | 362 | 324 | 449 | 384 | 545 | 500 | 575 | 533 | 510 | 605 |
240 | 424 | 380 | 528 | 450 | 644 | 590 | 679 | 634 | 607 | 719 |
300 | 486 | 435 | 306 | 514 | 743 | 681 | 783 | 736 | 703 | 833 |
400 | – | – | 383 | 584 | 868 | 793 | 940 | 868 | 823 | 1008 |
500 | – | – | 783 | 666 | 990 | 904 | 1083 | 998 | 946 | 1169 |
630 | – | – | 900 | 764 | 113 | 1033 | 1254 | 1151 | 1088 | 1362 |
Get more information connect with
Tina
Mobile: +86 157 3715 6317 (WhatsApp / Wechat)
Email: tina@ hdcable.com.cn
The packing picture of cable
As you know there are so many cable manufactures, ZHENGZHOU HONGDA CABLE CO., LTD is one of the biggest manufactures in china-mainland. We will give you a perfect shopping experience . If you need visit our factory , we will meet you at the airport or train station.
Also we can offer other service
Custom Merchandise:we can make cable as your need include the color ,size and so on.we also offer OEM .
Complete Course Tracking:we can offer you the service from the business begin to you get the cable and use it
Cable sample : we can offer the sample free
Cable Test Machine In Our Workshop
Certificate
If you have another question, pls feel free to contact us below
Tina
HENEN HONGDA CABLE CO., LTD.
Office: 21/F, Yaxing Times Square, Songshan Road, Erqi Zone, Zhengzhou 450000, China
Factory: Huijin Rd & Changping Rd, East Development Zone, Zhandian, Jiaozuo 454950, China.
Tel: +86 371 6097 5619 | Fax: +86 371 6097 5616
Email: tina @ hdcable.com.cn
Mobile: +86 15737156317 (WhatsApp / Wechat)
Skype ID: tinatian201603
- Next: 8 awg electrical wire 7 stranded copper conductor pvc insulated wire
- Previous: NYCWY – Low voltage power cable for installation in buildings (0.6/1 kV)
Contact us