iec power cable
1. ModeI No: JKYJ-Copper cored Aerial Cable, Cross-linked Polyethylene Insulated
KLYJ-Aluminum-cored Aerial Cable, Cross-linked Polvethvlene Insulated
JKY-Copper-cored Aerial Cable, Polyethylene Insulated
JKLY-Aluminum-cored Aerial Cable, Polvethvlene Insulated
JKLYJ/Q-Aluminum-cored Light Aerial Cable, Cross-linked Polyethylene Insulated
JKLY/Q-Aluminum-cored Light Aerial Cable, Polyethylene Insulated
2. Use: The products can be fixedly laid in aerial part of power transmission and distribution
Line project. Flexible-copper-cored cables are for use as out-let line of a transformer,
With rated A/C Voltage being 10KV.
3. Production Standards: GB14049-93
4. Opering Characteristics: A. Temperature should be of or above-20º C when laying.
B. Long time working temperature: Of or below 90º C for cross
Linked polyethylene insulated cable; Of or below
75º C for high-density polyethlene insulated cables.
C. Maximum temperature of the cable when there is a
Short-circuit occurs(lasting time less than 5s): 250º Cfor
Cross-linked polyethylene insulated cables; 150º C for
High-density polyethylene insulated cables.
D. Minimum bending radius allowed:
E. Single-cored: 20(cable outer diameter+conductor outer diameter)-5%, mm.
F. Multi-cored: 15(cable outer diameter+conductor outer diameter)-5%, mm.
KLYJ-Aluminum-cored Aerial Cable, Cross-linked Polvethvlene Insulated
JKY-Copper-cored Aerial Cable, Polyethylene Insulated
JKLY-Aluminum-cored Aerial Cable, Polvethvlene Insulated
JKLYJ/Q-Aluminum-cored Light Aerial Cable, Cross-linked Polyethylene Insulated
JKLY/Q-Aluminum-cored Light Aerial Cable, Polyethylene Insulated
2. Use: The products can be fixedly laid in aerial part of power transmission and distribution
Line project. Flexible-copper-cored cables are for use as out-let line of a transformer,
With rated A/C Voltage being 10KV.
3. Production Standards: GB14049-93
4. Opering Characteristics: A. Temperature should be of or above-20º C when laying.
B. Long time working temperature: Of or below 90º C for cross
Linked polyethylene insulated cable; Of or below
75º C for high-density polyethlene insulated cables.
C. Maximum temperature of the cable when there is a
Short-circuit occurs(lasting time less than 5s): 250º Cfor
Cross-linked polyethylene insulated cables; 150º C for
High-density polyethylene insulated cables.
D. Minimum bending radius allowed:
E. Single-cored: 20(cable outer diameter+conductor outer diameter)-5%, mm.
F. Multi-cored: 15(cable outer diameter+conductor outer diameter)-5%, mm.
Raw materials
Factory Show:
Package And Transportation:
Products Certifications:
Testing Equipment:
Technical quality Team:
We are specializing in the production of cables and wires,the spirt of us is "quality first, reputation first, service first, customer first"