Low tension 450/750V fire resistnt household PVC insulated halogen free copper conductor classe2 building wires
Port: | Tianjin |
Payment Terms: | L/C,T/T,Western Union |
Supply Ability: | 5000 Kilometer/Kilometers per Day |
Place of Origin: | Hebei China |
Brand Name: | HAOHUA |
Model Number: | Cu/PVC |
Type: | Insulated |
Application: | household appliance |
Conductor Material: | Copper |
Conductor Type: | Solid |
Insulation Material: | PVC |
Conductor: | Cu |
Voltage: | 450/700V |
Fire-resistant layer: | mica tape |
Conductor Type: | Solid |
Insulation material: | PVC |
Section area: | 1.5mm2~400mm2 |
Standard: | IEC60227 IEC 60332 |
Certifications: | CE ,CCC,ISO9001 |
Max Operating Temp: | 70°C or 90°C |
Color: | Red,blue,yellow or as reqired |
Packaging Detail: | Copper conductor classe2 building wires By rolls by carton box by paper reel by plastic spool by pallet or as required |
Low tension 450/750V fire resistnt household PVC insulated halogen free copper conductor classe2 building wires
Description
ENERGY CABLES Building & Construction Building Wire Single Core, Copper |
|
Application
For separate earth conductors. For switchboard and control panel wiring. For fixed wiring within other enclosures or apparatus where the cable is not accessible without the use of tools. |
STANDARD |
IEC60227-3:1997 |
CODEDESIGNATION |
60227 IEC 01 (BV, Cu/PVC) |
|
VOLTAGE |
450/750V |
|
CONDUCTOR |
Copper 1.5 – 185mm2 |
|
INSULATION |
PVC/C See below for colour options |
|
MAX. OPERATING TEMP. |
70°C |
TECHNICAL SPECIFICATIONS
ITEM NUMBER |
CONDUCTOR |
NOMINAL INSULATION THICKNESS /mm |
APPROX. OVERALL DIAMETER /mm |
APPROX. MASS
kg/km |
MINIMUM INSTALLED RADIUS /mm |
||||
mm2 |
No./mm |
||||||||
1000xxx |
1.5 |
1/1.38 |
0.7 |
2.78 |
21.1 |
18 |
|||
1001xxx |
1.5 |
7/0.52 |
0.7 |
2.96 |
21.9 |
18 |
|||
1002xxx |
2.5 |
1/1.78 |
0.8 |
3.38 |
32.9 |
20 |
|||
1003xxx |
2.5 |
7/0.68 |
0.8 |
3.64 |
34.9 |
20 |
|||
1004xxx |
4 |
1/2.25 |
0.8 |
3.85 |
48.0 |
23 |
|||
1005xxx |
4 |
7/0.85 |
0.8 |
4.15 |
49.9 |
23 |
|||
1006xxx |
6 |
1/2.76 |
0.8 |
4.36 |
67.9 |
26 |
|||
1007xxx |
6 |
7/1.04 |
0.8 |
4.72 |
70.2 |
26 |
|||
1008xxx |
10 |
1/3.56 |
1.0 |
5.56 |
111.4 |
33 |
|||
1009xxx |
10 |
7/1.34 |
1.0 |
6.02 |
114.8 |
33 |
|||
1010xxx |
16 |
7/1.68 |
1.0 |
7.04 |
171.1 |
42 |
|||
1011xxx |
25 |
7/2.12 |
1.2 |
8.76 |
268.9 |
53 |
|||
1012xxx |
35 |
7/2.50 |
1.2 |
9.90 |
363.1 |
59 |
|||
1013xxx |
50 |
19/1.76 |
1.4 |
11.60 |
488.8 |
70 |
|||
1014xxx |
70 |
19/2.12 |
1.4 |
13.40 |
690.1 |
80 |
|||
1015xxx |
95 |
19/2.50 |
1.6 |
15.70 |
954.8 |
94 |
|||
1016xxx |
120 |
37/2.00 |
1.6 |
17.20 |
1174.9 |
103 |
|||
1017xxx |
150 |
37/2.22 |
1.8 |
19.14 |
1448.7 |
115 |
|||
1018xxx |
185 |
37/2.48 |
2.0 |
21.36 |
1805.7 |
128 |
|||
• xxx=001 for Black |
• xxx=002 for Blue |
• xxx=003 for Brown |
• xxx=004 for Grey |
||||||
• xxx=005 for Red |
• xxx=006 for Green/Yellow |
• xxx=007 for Green |
• xxx=008 for Yellow |
Technical Prameter – Continued
CONDUCTOR |
CURRENT RATING (a) |
ELECTRICAL CHARACTERISTICS |
||||
Nominal Area mm2 |
FIXED WIRING |
Maximum DC Resistance @20℃ Ω/km |
Maximum AC Resistance @90℃ Ω/km |
Equivalent Star Reactance (trefoil) Ω/km |
Single Phase Voltage Drop (trefoil) @90℃ mV/Am |
|
Unenclosed In Air |
Conduit In Air |
|||||
1.5 |
16 |
16 |
13.6 |
17.3 |
0.157 |
34.7 |
2.5 |
23 |
24 |
7.41 |
9.45 |
0.143 |
18.9 |
4 |
31 |
32 |
4.61 |
5.88 |
0.137 |
11.8 |
6 |
40 |
41 |
3.08 |
3.93 |
0.128 |
7.87 |
10 |
54 |
54 |
1.83 |
2.33 |
0.118 |
4.68 |
16 |
72 |
70 |
1.15 |
1.47 |
0.111 |
2.95 |
25 |
97 |
94 |
0.727 |
0.927 |
0.106 |
1.87 |
35 |
119 |
112 |
0.524 |
0.668 |
0.101 |
1.35 |
50 |
146 |
138 |
0.387 |
0.494 |
0.0962 |
1.01 |
70 |
184 |
170 |
0.268 |
0.342 |
0.0917 |
0.710 |
95 |
230 |
212 |
0.193 |
0.247 |
0.0904 |
0.528 |
120 |
267 |
242 |
0.153 |
0.197 |
0.0870 |
0.431 |
150 |
308 |
282 |
0.124 |
0.160 |
0.0868 |
0.365 |
185 |
358 |
320 |
0.0991 |
0.129 |
0.0862 |
0.329 |
240 |
428 |
361 |
0.0754 |
0.0991 |
0.0847 |
0.283 |
(a) Based on 40℃ ambient air temperature.
The above information is from the following sources:
• IEC 60287 Electric cables – Calculation of the current rating (all Parts)
• IEC 60364 Electrical installations of buildings
• IEC 60228 Conductors of insulated cables
Do not put in direct contact with polystyrene, polyurethane or similar thermal insulation materials.
Advantage
Workshop
Color to choose
Red, yellow, blue, green, black, white, or as required
24 hours online Technical support service
- Next: 11KV twisted 95mm2 overhead ABC Cable
- Previous: Transmission line overhead Zebra /Rabbit /Linnet acsr conductor
Contact us
Search
You May Like
- No related articles