instrument cable RE-2X(St)HSWAH-PIMF cable

Port: | Shanghai, Qingdao, Ningbo, Shenzhen |
Payment Terms: | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
Supply Ability: | 1500 Kilometer/Kilometers per Month |
Place of Origin: | Henan China |
Brand Name: | Hongda |
Model Number: | DJYJVP |
Shielding: | Foil |
Conductor Material: | Copper |
Jacket: | PVC |
Insulation Material: | XLPE |
Applications: | used for safety for the transmission |
Conductor: | Annealed or tinned copper |
Sizes: | 0.5mm~2 and 1.5mm~2 |
Insulation: | XLPE |
Voltage Rating: | 300/500V |
Outer Sheath: | PVC (Flame retardant, sunlight, mineral oil and hydrocarton resistant) |
Maximum Voltage: | 250V |
Voltage Test: | 2000V |
Operating Temperature: | -40°C/+90°C |
Installation Temperature: | MAX+50°C |
Packaging Detail: | Pack in drum, other packaging can be customized for EN 50288-7 Instrumentation Cables |
EN 50288-7 Instrumentation Cables
XLPE Insulated, LSZH Sheathed, Individual and Overall Screened Instrumentation Cables (Multipair)
RE-2X(St)H Pimf 90°C / 300V
communication cable Applications
The unarmoured LSZH sheathed cables are generally use for indoor installation and suitable for wet and damp areas. Generally, the cables are used within industrial process manufacturing plants for communication, data and voice transmission signals and services. Also used for the interconnection of electrical equipment and instruments, the LSZH sheath can reduce toxic smoke and fume emission.
communication cable Construction
Conductor | Annealed copper solid or plain copper stranded to IEC 60228 Class 2. |
Insulation | Extruded cross-linked XLPE compound, EN 50290. 2-29. |
Pairing | Two insulated conductors uniformly twisted together with a lay not exceeding 100mm |
Individual Screen | Aluminium/polyester tape is applied over each pair metallic side down in contact with tinned copper drain wire, 0.5mm² |
Binder tape | PETP transparent tape |
Overall Screen | Aluminium/polyester tape is applied over the laid up pairs metallic side down in contact with tinned copper drain wire, 0.5mm² |
Outer sheath | Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655 2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. |
Insulation | Black / White, continuously numbered on white core(1, 2..)for multipair. |
Outer Sheath | Black or blue for intrinsically safe systems |
FIRE PERFORMANCE
Flame Retardance (Single Vertical Wire Test) | EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
Reduced Fire Propagation (Vertically-mounted bundled wires & cable test) | EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Halogen Free | IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1* |
No Corrosive Gas Emission | IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2* |
Minimum Smoke Emission | IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
No Toxic gases | NES 02-713; NF C 20-454 |
Sunlight Resistance | UL 1581 section 1200 |
Oil Resistance | ICEA S-73-532** |
Note: Asterisk * denotes superseded standard, ** denotes Test temperature +60°C, duration 4h. Retention: min 60% of tensile strength/min.60% of elongation, *** denotes optional.
VOLTAGE RATING
300V
Physical AND THERMAL PROPERTIES
Temperature Range During Operation (Fixed State): -30°C – +90°C
Temperature Range During Installation (Mobile State): -5°C – +50°C
Minimum Bending Radius: 7.5 X Overall Diameter
communication cable Parameter
RE-2X(St)H PiMF | ||||
No. of Pairs x2xCross Section | Nominal Insulation Thickness | Nominal Outer Sheath Thickness | Nominal Overall Diameter | Approx. Weight |
No.x2xmm2 | mm | mm | mm | kg/km |
0.5mm2, Multipair | ||||
2x2x0.5 | 0.35 | 0.9 | 8.7 | 85 |
4x2x0.5 | 0.35 | 1.0 | 10.2 | 120 |
5x2x0.5 | 0.35 | 1.0 | 11.2 | 145 |
6x2x0.5 | 0.35 | 1.0 | 12.1 | 170 |
8x2x0.5 | 0.35 | 1.1 | 13.1 | 214 |
10x2x0.5 | 0.35 | 1.2 | 15.1 | 265 |
12x2x0.5 | 0.35 | 1.2 | 15.7 | 286 |
16x2x0.5 | 0.35 | 1.2 | 17.8 | 380 |
20x2x0.5 | 0.35 | 1.3 | 19.7 | 475 |
24x2x0.5 | 0.35 | 1.4 | 21.5 | 561 |
0.75mm2, Multipair | ||||
2x2x0.75 | 0.38 | 1.0 | 9.7 | 101 |
3x2x0.75 | 0.38 | 1.0 | 11.2 | 159 |
4x2x0.75 | 0.38 | 1.1 | 12.5 | 183 |
5x2x0.75 | 0.38 | 1.1 | 13.6 | 215 |
8x2x0.75 | 0.38 | 1.1 | 14.4 | 272 |
10x2x0.75 | 0.38 | 1.2 | 16.6 | 333 |
12x2x0.75 | 0.38 | 1.2 | 17.4 | 383 |
16x2x0.75 | 0.38 | 1.3 | 19.8 | 492 |
20x2x0.75 | 0.38 | 1.4 | 22.0 | 603 |
24x2x0.75 | 0.38 | 1.5 | 24.0 | 704 |
1.0mm2, Multipair | ||||
2x2x1.0 | 0.4 | 1.0 | 10.4 | 112 |
3x2x1.0 | 0.4 | 1.0 | 12.1 | 179 |
4x2x1.0 | 0.4 | 1.1 | 13.5 | 220 |
5x2x1.0 | 0.4 | 1.1 | 14.7 | 256 |
8x2x1.0 | 0.4 | 1.2 | 15.8 | 323 |
10x2x1.0 | 0.4 | 1.2 | 18.0 | 401 |
12x2x1.0 | 0.4 | 1.3 | 19.0 | 454 |
16x2x1.0 | 0.4 | 1.3 | 21.5 | 601 |
20x2x1.0 | 0.4 | 1.4 | 23.9 | 719 |
24x2x1.0 | 0.4 | 1.5 | 26.1 | 884 |
1.3mm2, Multipair | ||||
2x2x1.3 | 0.45 | 1.0 | 11.4 | 153 |
3x2x1.3 | 0.45 | 1.1 | 13.4 | 208 |
4x2x1.3 | 0.45 | 1.1 | 14.8 | 263 |
5x2x1.3 | 0.45 | 1.2 | 16.3 | 318 |
8x2x1.3 | 0.45 | 1.3 | 17.6 | 406 |
10x2x1.3 | 0.45 | 1.3 | 20.0 | 501 |
12x2x1.3 | 0.45 | 1.4 | 21.1 | 552 |
16x2x1.3 | 0.45 | 1.5 | 24.1 | 728 |
20x2x1.3 | 0.45 | 1.6 | 26.8 | 892 |
24x2x1.3 | 0.45 | 1.7 | 29.2 | 1067 |
1.5mm2, Multipair | ||||
2x2x1.5 | 0.45 | 1.0 | 11.8 | 164 |
3x2x1.5 | 0.45 | 1.1 | 13.9 | 235 |
4x2x1.5 | 0.45 | 1.2 | 15.5 | 289 |
5x2x1.5 | 0.45 | 1.2 | 16.9 | 366 |
8x2x1.5 | 0.45 | 1.3 | 18.2 | 446 |
10x2x1.5 | 0.45 | 1.4 | 21.0 | 565 |
12x2x1.5 | 0.45 | 1.4 | 21.9 | 637 |
16x2x1.5 | 0.45 | 1.5 | 25.1 | 828 |
20x2x1.5 | 0.45 | 1.6 | 27.8 | 1024 |
24x2x1.5 | 0.45 | 1.7 | 30.4 | 1219 |
Note : Other conductor sizes & core configurations are available upon request
Electrical PROPERTIES
Conductor Area Size | mm 2 | 0.5 | 0.75 | 1.0 | 1.3 | 1.5 | |
Insulation thickness (nominal) | mm | 0.4 | 0.4 | 0.4 | 0.45 | 0.45 | |
Conductor resistance (20°C) | Ω/km | 36.7 | 25 | 18.5 | 14.2 | 12.3 | |
Insulation resistance (20°C) | MΩ.km(Min.) | 5000 | |||||
Mutual Capacitance (1 kHz) | pF/m(Max.) | 115 | |||||
Inductance | mH/km (Max.) | 1 | |||||
L / R (ratio) (max.) | μH/Ω | 25 | 25 | 25 | 40 | 40 | |
Operating voltage Urms | V | 300 | |||||
Test Voltage | Core to Core | V | 1500 | ||||
Core to Screen | V | 1500 |
Packing:
Steel wooden drum (fumigation)
Cable length in each drum: 500m/1000m or as per actual cable length requirements.
Drum size:
As per cable length and container size
*In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!
Shipping:
Port: Tianjin, Qingdao, or other ports as per your requireents.
Sea freight:
FOB/C&F/CIF quotation are all available.
Company Profile
Hongda cable Co., Ltd. is one of the most professional cable & wire producer under modern enterprise system in China, which was founded in 1988, integrating scientific research, development, production and sales. The company mainly produces 1-35 kV power cable, ABC cable, AAC, AAAC, ACSR.
Our advantages
1. With more than 17 years manufacturing experience, our products are strictly in accordance with ISO, CE, UL and BV;
2. Good cost-control system, with highly-competitive prices;
3. Strong and Professional R&D team to meet your specific needs;
4. Fast delivery&reliable products are always the reason why you choose us.
Contact information
Any needs or question ,please contact us ,we will be more pleasure to service you.