Industrial heating application self regulating heating wire for house ,for roof ,for now frosting protection From ZMS

Port: | erlian to mongolia |
Payment Terms: | L/C,D/P,T/T |
Supply Ability: | 100 Kilometer/Kilometers per Week |
Place of Origin: | Henan China |
Brand Name: | ZMS cable |
Model Number: | 15w/m 110V 220v 380v |
Type: | Insulated |
Application: | Heating |
Conductor Material: | Copper |
Conductor Type: | Stranded |
Insulation Material: | FEP |
Application: | Iinstallation under tile, wooden floor, marble. |
Conductor Material: | Tinned Copper |
Type: | Low Voltage heating appliacation |
Shield Option 1: | Aluminum foil-polyester tape with solid tinned copper drain wire |
Shield Option 2: | Tinned copper wire shield |
Shield Option 3: | Copper tape shield |
Rated Voltage: | AC/DC 110-120/208-277V |
Product name: | 220v electric underground heating cable |
Color: | Black,blue,red |
Packaging Detail: | standard export wooden drums or as your requirements |
OVERVIEW:
Heating cables are made for a wide variety of industrial, commercial and residential applications. By offering an array of cable technologies — such as self regulating, power limiting, mineral insulated, skin effect, constant wattage and series resistance — our heating cables meet the needs of most applications including process temperature maintenance, pipe freeze protection, longline heating, flow assurance, hot water temperature maintenance, roof and gutter de-icing, surface snow melting, frost heave prevention and floor heating.
Our self-regulating heating cables are the same function as abroad thermon BSX 8-2-FOJ Raychem BTV type .Our heating cable has below feature :
1. Pipeline temperature is uniform, safe and reliable
2 installation and operation costs low, easy maintenance
3. Intermittent operation, warming up fast
4.Save energy and save costs
APPLICATION :
*Pipe Freeze Protection
*Long Pipeline Heating
*Process Temperature Maintenance
*Tank Heating
*Frost Heave Prevention
*Roof Gutter De-lcing
*Surface Snow Melting
Operating Voltage: 110-120 or 208-277 VAC or 380-480VAC
TEMPERATURE :
Max. conductor temperature on continuous:75℃,105℃,135℃
Maximum conductor short time temperature:105℃,135℃,155℃
Minimum construction temperature:-40℃
Minimum Self-Regulating Indices | ||
Heating cable | S.R index (W/°F) | S.R index (W/°C) |
3 W/ft | 0.038 | 0.068 |
5 W/ft | 0.060 | 0.108 |
8 W/ft | 0.074 | 0.133 |
10 W/ft | 0.100 | 0.180 |
CONSTRUCTION :
No. | ITEMS | UNIT | TECHNICAL PARTICULARS |
2*1.3mm2 | |||
1 | Standard Applied | IEC60898 | |
2 | Rated Voltage | V | 220 |
3 | Number of Cores | No. | 2 |
4 | Conductor | ||
— Cross sectional area | MM2 | 1.3mm2 | |
— Material | Nickel plated Copper wire | ||
— Type of conductor | Round | ||
— No. and dia of strands | Nos./mm | 19/0.3 | |
— Diameter | mm | 1.6 | |
5 | Conductor screen | ||
— Material | Semi-conductive conductor screen | ||
— Nominal thickness | mm | 2 | |
6 | Insulation | ||
— Material | Radiation Cross-Linked Dielectric Insulation | ||
— Nominal thickness | 0.7 | ||
7 | Tinned Copper Braid | mm | 0.3 |
8 | Jacket | ||
— Material | Fluoro polymer over jacket | ||
— Nominal thickness | mm | 0.7 | |
9 | OD of the finished cable (Approx.) | mm | 5.3mm*11mm |
10 | Weight of the finished cable (Approx.) | Kg/km | 90 |
11 | Min. bending radius at laying in terms of cable diameter | D | 10D |
12 | D.C Testing voltage | V/min | 2500V/1 |
13 | Max. conductor temperature on continuous | °C | 135 |
14 | Maximum conductor short time temperature | °C | 220 |
:
FAQ :
Q:What are Self-Regulating Heating Cables?
A:1.Any heating cable providing a watt output which increases as temperatures fall and decreases as temperatures rise. Self-regulating heating cables use a carbon matrix-heating element with variable resistance.
2.Self-regulating cables have a conductive polymer-heating element where the resistance exhibits a PTC characteristic, the resistance of the element increases with temperature. Conversely, the cable’s power output decreases with increasing temperature. As the temperature increases the cable power output approaches zero. At this temperature the cable effectively “shuts off”. A hazardous area T-rating can be assigned to self-regulating cables regardless of installation conditions.
3.Being a parallel construction, the self-regulating heating cable can adjust its power output for local condition along its length.
Q:Can TubeTrace be manufactured with different colored outer jackets?
A:Yes, most any color is possible. Additional manufacturing set-up costs may apply.
Q:For heat tracing systems, is thermal insulation really necessary?
A:Yes. The heat losses without thermal insulation are excessive and not practical to compensate for with heat tracing.
Related Products
0.6/1kv ABC twist cable | aac aaac acsr | ARMORED CABLE |
HIGH VOLTAGE SCREENED ABC | 4 core 95mm2 abc | concentirc aluminum conductor cable transmission |
- Next: 0.6/1KV 12/20KV 26/35KV ZRC-YJV YJV22 YJV32 Cable Cu/XLPE/SWA/PVC XLPE Insulated underground power cable
- Previous: LV multi core XLPE Insulated Free with IEC60502 LSZH Low Smoke Zero Halogen Fire Retardent Cable