Flame Retardant Copper Power Cable VVG VVG-P VVGNG

Port: | Qingdao |
Payment Terms: | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
Supply Ability: | 500 Kilometer/Kilometers per Month |
Place of Origin: | Henan China |
Brand Name: | Hongda |
Model Number: | VVG AVVG |
Insulation Material: | PVC |
Type: | Low Voltage |
Application: | Construction |
Conductor Material: | Copper |
Jacket: | PVC |
Product name: | Flame Retardant Copper Aluminum Power Cable VVG AVVG |
Rated voltage: | 600/1000 Volts |
Conductor: | Copper or Aluminum |
Insulation: | PVC |
Sheath: | PVC |
Color: | Black |
Standard: | BS IEC ASTM DIN |
Certificate: | ISO9001 |
Core: | Multi-core |
Delivery Detail: | About 15 days or as your order quantity |
Packaging Detail: | Standard export wooden drum |
Flame Retardant Copper Power Cable VVG VVG-P VVGNG
Construction:
1. Conductor – copper, single or multiwire, round- or sector-shaped, 1 or 2 class as per GOST 22483.
2. Insulation – PVC. Insulated multiconductor cable conductors carry identification coloring. Neutral conductor insulation is blue. Grounding conductor insulation is in two colors (yellow-green).
3. Twisting – Insulated conductors of two-, three-, four-, and five- conductor cables are twisted. Two conductor cables feature conductors of the same area. Three-, four-, and five- conductor cables feature all the conductors of the same area or one conductor (ground or neutral one ) of a smaller area.
4. Jacket – PVC, VVng cables are sheathed with flameretardant PVC.
Application:
These cables are intended for distributing electric power in fixed installations rated for nominal alternating voltages of 0.66 KV and 1 KV 50 Hz. They are meant for laying inside both dry and wet industrial premises on special trestles, in assemblies as well as for laying outdoors. Cables are not recommended for burying in trenches.
VVG cables are flameretardant if laid individually.
VVGng cables are flameretardant if laid in bunches.
Operation temperature |
– 50 °C … + 50 °C
|
Minimum installation temperature without prior heating |
-15°C
|
Admissible continuous temperature of conductors |
+70°C
|
Minimum installation bending radius
– single-conductor cable
– multi-conductor cable
|
10 cable diameters |
Minimum service life |
30 years
|
Cable types |
Rated outer dimensions of the cable, mm (reference) |
Weight of conductors, kg/km
(reference)
|
Cable's weight, kg/km
(reference) |
VVG-P 2*1,5 (single) – 1 |
5,4*8,4
|
27
|
76
|
VVG-P 2*2,5 (single) – 1 |
5,8*9,2
|
44
|
100
|
VVG-P 2*4,0 (single) – 1 |
6,7*10,9
|
71
|
146
|
VVG-P 2*6,0 (single) – 1 |
7,2*11,9
|
106
|
192
|
VVG-P 2*10,0 (single) – 1 |
8,0*13,5
|
178
|
279
|
VVG-P 2*16,0 – 1 |
10,1*17,2
|
288
|
447
|
VVG-P 3*1,5 (single) – 1 |
5,4*11,3
|
40
|
112
|
VVG-P 3*2,5 (single) – 1 |
5,8*12,5
|
66
|
148
|
VVG-P 3*4,0 (single) – 1 |
6,7*15,2
|
106
|
217
|
VVG-P 3*6,0 (single) – 1 |
7,2*16,7
|
–
|
–
|
VVG-P 3*10,0 (single) – 1 |
8,0*19,1
|
267
|
419
|
VVG-P 3*16,0 – 1 |
10,1*24,3
|
–
|
–
|
VVG 2*25,0 – 1 |
22,9
|
459
|
818
|
VVG 2*35,0 – 1 |
25,7
|
636
|
1077
|
VVG 3*1,5 (single) – 1 |
9,4
|
40
|
116
|
VVG 3*2,5 (single) – 1 |
10,3
|
67
|
152
|
VVG 3*4,0 (single) – 1 |
12,1
|
107
|
220
|
VVG 3*6,0 (single) – 1 |
13,3
|
160
|
286
|
AVVG 3*16,0+1*10,0 (single)- 1 |
19,1
|
157
|
379
|
VVG 3*10,0 (single) – 1 |
15,0
|
269
|
418
|
VVG 3*16,0 – 1 |
18,7
|
434
|
653
|
VVG 3*25,0 – 1 |
22,9
|
688
|
1007
|
VVG 3*35,0 – 1 |
25,7
|
955
|
1338
|
VVG 3*2,5+1*1,5 (single) – 1 |
11,2
|
80
|
179
|
VVG 3*4,0+1*2,5 (single) – 1 |
13,3
|
129
|
258
|
VVG 3*6,0+1*4,0 (single) – 1 |
14,5
|
196
|
348
|
VVG 3*10,0+1*6,0 (single) – 1 |
16,4
|
322
|
497
|
VVG 3*16,0+1*10,0 – 1 |
18,7
|
520
|
759
|
VVG 3*25,0+1*16,0 – 1 |
23,3
|
832
|
1201
|
VVG 3*35,0+1*16,0 – 1 |
28,3
|
1098
|
1533
|
VVG 4*1,5 (single) – 1 |
10,2 |
54 |
142
|
VVG 4*2,5 (single) – 1 |
11,2 |
89 |
189 |
VVG 4*4,0 (single) – 1 |
13,3 |
142 |
277 |
VVG 4*6,0 (single) – 1 |
14,5 |
214 |
366 |
VVG 4*10,0 (single) – 1 |
16,4 |
358 |
537 |
VVG 4*16,0 – 1 |
20,5 |
579 |
842 |
VVG 4*25,0 – 1 |
25,5 |
918 |
1324 |
VVG 4*35,0 – 1 |
28,3 |
1273 |
1732 |
VVG 5*1,5 (single) – 1 |
11,1 |
67 |
173 |
VVG 5*2,5 (single) – 1 |
12,1 |
111 |
233 |
VVG 5*4,0 (single) – 1 |
14,5 |
178 |
344 |
VVG 5*6,0 (single) – 1 |
15,9 |
268 |
457 |
VVG 5*10,0 (single) – 1 |
18,4 |
448 |
690 |
VVG 5*16,0 – 1 |
22,6 |
724 |
1060 |
VVG 5*25,0 – 1 |
27,6 |
1147 |
1632 |
VVG 5*35,0 – 1 |
30,7 |
1591 |
2147 |
Zhengzhou hongda cable Co., Ltd.
Established Year: 1999
Registered capital of RMB:5,000,000
Factory Area:300,000m2
Main products:
Areial bundle cable ,XLPE insulated power cable ,PVC insulated power cable ,electrical wire ,bare aluminum conductor(AAC AAAC ACSR )and so on
Main export county:
USA Philippines Malaysia Indonesia Venezuela, Colombia Mexico
Dominica India South Africa Zambia Kenya and so on .
1. We have a large production base, and advanced production equipment
2. Have an competitive price and high quality
3. Excellent after-sale service
4. Free issue:packaging list,invoice
5. Powerful technology team
6. Strict quality assurance system and perfect testing means
7. Advanced process equipment
8. Delivery on time
9. Our cable sales to Middle East,Africa,Russia,Southeast Asia, etc.
10.We have a good reputation in the overseas
Q: Are you trading company or manufacturer ?
A: We are factory.
Q: How long is your delivery time?
A: Generally it is 5-10 days if the goods are in stock. or it is 15-20 days if the goods are not in stock, it is according to quantity.
Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge but do not pay the cost of freight.
Q: What is your terms of payment ?
A: 30% T/T in advance,70% T/T balance before shipment
Tina Sales Director
|