Fire Resistant 4core LV Armoured Electrical Cable XLPE Insulated Copper Core Steel Wire Armored Cable

Fire Resistant 4core LV Armoured Electrical Cable XLPE Insulated Copper Core Steel Wire Armored Cable
Payment Terms: L/C,T/T
Place of Origin: Shanghai China
Brand Name: SAHN, OEM
Model Number: fire resistant cable, YJV22, YJV32, YJV72, NH--YJV
Insulation Material: xlpe or pvc
Type: Low Voltage
Application: Power Station
Conductor Material: Copper
Jacket: PVC
Product name: Fire Resistant 4core LV Armoured Electrical Cable XLPE Copper Cable
Voltage: low voltage, 0.6/1kV
Conductor: Copper
Insulation: XLPE or PVC
Armour: Steel tape armour, Steel wire or Aluminum wire armor, or unarmored
Sheath: PVC, ZR-PVC, PE, LSOH
Special requiremets: Fire-resistant, flame retardant, low smoke halogen free
Fire proof: Mica tape
Certificates: CE, RoHS, CCC, KEMA
Warranty: 2 years since delivery

Fire Resistant 4core LV Armoured Electrical Cable XLPE Insulated Copper Core Steel Wire Armored Cable

 

Application:

To be laid directly in ground, outdoors, indoors and in cable ducts.

Used for tall building, Hospital, Theatre, Power station, Metro Tunnel or Petrochemical Industry or other special place required for low smoke , zero halogen clean and safe cable.

 

 

Construction:

 

1 ….. stranded (RM) bare copper
2 ….. Mica Tape for Fire Resistant 
3 ….. core insulation of cross-linked polyethylene
4 ….. Fillers
5 ….. Wrapping tape or Flame Retardant tape

6 ….. PVC Inner Bedding 

7 ….. Galvanized Steel Wire Armour
8 ….. outer sheath of polyvinylchloride (PVC)

 

Standards:

 

IEC 60502, 60228, 60332, 60331

DIN VDE 0276-620
HD 620 S1: 1996
DIN EN 60228 class 2 (construction)

Technical data:

Test voltage 0.6/1 kV [kV] 3.5 / 5 min.
Temperature range in motion -5°C till +70°C
fixed -20°C till +70°C
Operating temperature short circuit °C 250
Short circuit time max. [sec] 5
Bending radius min. x diameter 15
Flammability standard EN 60332-1-2

 

 

Specifications:

 

Nom. Cross-section of conductor

Strands

No./Dia. Of Conductor

Insulation Thickness Inner Covering Thickness Dia. Of Armor Wire Sheath Thickness Approx. O.D.

Approx.

Weight

Max. D.C Resistance of Conductor (20 ℃) Testing Voltage A.C Current Rating
mm2 pc/mm mm     mm (mm) kg/km Ω /km kV/5min In air (A) In soil(A)
4 × 4 7/0.85 0.7 1.0 0.9 1.8 18.0 699 4.61 3.5 34 45
4 × 6 7/1.04 0.7 1.0 1.25 1.8 19.0 820 3.08 3.5 43 57
4 × 10 7/1.38 0.7 1.0 1.25 1.8 22.0 1233 1.83 3.5 60 77
4 × 16 7/1.78 0.7 1.0 1.6 1.8 24.5 1550 1.15 3.5 83 105
4 × 25 7/2.14 0.9 1.0 1.6 1.8 29.2 2036 0.727 3.5 105 125
4 × 35 7/2.52 0.9 1.0 2.0 1.9 32.5 2501 0.524 3.5 125 155
4 × 50 10/2.52 1.0 1.0 2.0 2.0 33.0 3064 0.387 3.5 160 185
4 × 70 14/2.52 1.1 1.0 2.0 2.1 37.0 3974 0.268 3.5 200 225
4 × 95 19/2.52 1.1 1.2 2.0 2.3 43.0 5032 0.193 3.5 245 270
4 × 120 24/2.52 1.2 1.2 2.5 2.5 45.0 6327 0.153 3.5 285 310
4 × 150 30/2.52 1.4 1.4 2.5 2.7 51.0 7765 0.124 3.5 325 345
4 × 185 37/2.52 1.6 1.4 2.5 2.8 56.0 9205 0.0991 3.5 375 390
4 × 240 48/2.52 1.7 1.4 2.5 3.0 62.0 11444 0.0754 3.5 440 450
4 × 300 61/2.52 1.8 1.6 2.5 3.2 67.0 13830 0.0601 3.5 505 515
4 × 400 61/2.97 2.0 1.6 3.15 3.5 74.0 19673 0.0470 3.5 570 575

 

 
Certification

CERTIFICATION

 

Factory show

FACTORY SHOW

 

PRO.&INS. Process

 

PACKING AND SHIPPING

 
Packing and shipping

We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.

Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.

 

 

You can contact me directly for soonest response 🙂

 

 

 

 

 