Duplex Service Drop Wire ABC Aerial Bundle Cable Pekingese 6 awg

Port: | Qingdao or Shanghai or Shenzhen |
Payment Terms: | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
Supply Ability: | 300 Kilometer/Kilometers per Month |
Place of Origin: | Henan China |
Brand Name: | Hongda |
Model Number: | Service Cable |
Insulation Material: | XLPE PE PVC |
Type: | Low Voltage |
Application: | Overhead |
Conductor Material: | Aluminum |
Jacket: | NO sheath |
Product name: | Duplex Service Drop Wire ABC Aerial Bundle Cable Pekingese 6 awg |
Conductor: | Alulminum |
Color: | Black |
Core: | Duplex Triplex Quadruplex |
Rated voltage: | 0.6/1KV |
Character: | UV Proof Weather Resistant |
Standard: | NFC 33209 IEC |
Packaging Detail: | Packaging in roll or wooden drum |
Duplex Service Drop Wire ABC Aerial Bundle Cable Pekingese 6 awg
Get more information connect with
Tina
Mobile: +86 157 3715 6317 (WhatsApp / Wechat)
Email: tina@ hdcable.com.cn
Application
The aerial bundled cables designed for overhead distribution lines have all conductors made of aluminium 1350 and insulated with XLPE. Phase and neutral cores are laid up in a bundle with a left hand lay. Can be used for fixed installation as overhead power lines up to 1000 V incl.
Standard
- BS 7870-5:1999
- NFC 33-209
- IEC 60502
- AS/NZS 3560.1
- Construction
Conductor (for either phase, neutral or street lighting) | The conductors shall be of aluminium 1350 wires and are compacted circular stranded(RM). |
---|---|
Insulation | XLPE. 1, 2 and 3 raised longitudinal ribs on the surface of the cores. The surface of the neutral core should have at least 12 ribs for cross-sections up to 50 mm^2 and a minimum of 16 ribs for cores above 50 mm^2. In the case of five core bundles the surface of the protective core should be smooth. |
Assembly | 2 up to 4 cores of equal cross section are stranded together in left-hand lay, additionally 1 or 2 cores of reduced cross section can be co-stranded. |
- Technical Data
Rated voltage | kV | 0.6/1 |
Test voltage | Veff kV | 4 |
Laying temperature | °C | min. -20 |
Operating temperature | °C | -30 ~ +80 |
Conductor temperature | °C | max. +80 |
Short-circuit temperature | °C/s | max. +130 /5 |
Bending radius (min.) | 18 × o of cable |
Type | Application |
Duplex Service Drop |
To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75°C maximum. |
Triplex Service Drop |
To supply power from the utility's lines to the consumer's weatherhead.For service at 600 volt or less (phase to phase) at a conductor temperature of 75°C maximumfor polyethylene insulation 90°C maximum for crosslinked insulation. |
Quadruplex Service Drop |
Used to supply 3 phase power, usually from a polemounted transformer, to the user'sservice head where connection to the service entrance cable is made. To be used at voltages of 600volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethyleneinsulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors.
|
Aerial bundle cable / Triplex Service Drop-Aluminum Conductor, ASTMB-232 | ||||||||||
Code Name | Phase Conductors(AAC) | Bare Neutral(AAAC) | Weight | Ampacity | ||||||
Size/no of wires | Insulation thickness | Nominal Diameter | Size/no of wire | rated strength | XLPE | Aluminum | Total | |||
Bare | OD | |||||||||
mm | mm | mm | kg | kg/km | kg/km | kg/km | A | |||
Fulgur | 3/0-19 | 1.52 | 11.9 | 15 | 1/0-7 | 2023 | 168 | 650 | 819 | 242 |
Balanus | 3/0-19 | 2.03 | 11.9 | 16 | 1/0-7 | 2023 | 216 | 650 | 868 | 242 |
Stonecrab | 3/0-7 | 1.52 | 11.8 | 14.8 | 3/0-7 | 3080 | 165 | 752 | 917 | 242 |
Flustra | 3/0-7 | 1.52 | 11.9 | 15 | 3/0-7 | 3080 | 168 | 752 | 920 | 242 |
Crisia | 3/0-19 | 2.03 | 11.9 | 16 | 3/0-7 | 3080 | 216 | 752 | 969 | 242 |
Squid | 4/0-7 | 1.52 | 13.3 | 16.3 | 2/0-7 | 2431 | 191 | 820 | 1011 | 279 |
Arca | 4/0-19 | 1.52 | 13.4 | 16.5 | 2/0-7 | 2431 | 192 | 820 | 1012 | 279 |
Bugula | 4/0-19 | 2.03 | 13.4 | 17.5 | 2/0-7 | 2431 | 246 | 820 | 1066 | 279 |
Kingerab | 4/0-7 | 1.52 | 13.3 | 16.3 | 4/0-7 | 3883 | 191 | 948 | 1137 | 279 |
Lepas | 4/0-19 | 1.52 | 13.4 | 16.5 | 4/0-7 | 3883 | 192 | 948 | 1140 | 279 |
Cassi | 4/0-19 | 2.03 | 13.4 | 17.5 | 4/0-7 | 3883 | 246 | 948 | 1194 | 279 |
Get more information connect with
Tina
Mobile: +86 157 3715 6317 (WhatsApp / Wechat)
Email: tina@ hdcable.com.cn
Zhengzhou Hongda Cable Co., Ltd. was established in March of 1999. Our company owns registered capital of RMB6,000,000. Our company covers an area of 46,000 square meters, including 20,000 square meters of building area, and has more than 120 staff members and professional workers accounting for above one quarter.
We mainly aim at managing cross-linking XLPE insulated power cables, PVC insulated power cables, plastic insulated control cables, insulated overhead cables, and stranded aluminum and ACSR. At present, the cables' biggest cross area is 500 square meters with a maximum electric power of 10KV, and the annual producing capacity is 20,000 kilometers.
If you have another question, pls feel free to contact us below
Tina
HENEN HONGDA CABLE CO., LTD.
Office: 21/F, Yaxing Times Square, Songshan Road, Erqi Zone, Zhengzhou 450000, China
Factory: Huijin Rd & Changping Rd, East Development Zone, Zhandian, Jiaozuo 454950, China.
Tel: +86 371 6097 5619 | Fax: +86 371 6097 5616
Email: tina @ hdcable.com.cn
Mobile: +86 15737156317 (WhatsApp / Wechat)
Skype ID: tinatian201603