DIN 48204 Compact Aluminum ACSR Conductor 120mm2

DIN 48204 Compact Aluminum ACSR Conductor 120mm2
Port: qing dao
Payment Terms: L/C,D/A,T/T
Supply Ability: 10000000 Kilometer/Kilometers per Month
Place of Origin: Henan China
Brand Name: JIN SHUI
Model Number: DIN 48204 Compact Aluminum ACSR Conductor 120mm2
Insulation Material: bare
Type: Medium Voltage
Application: Overhead
Conductor Material: Aluminum
Jacket: bare
Product name: DIN 48204 Compact Aluminum ACSR Conductor 120mm2
Delivery Detail: within 15 days after receiving the payment
Packaging Detail: wooden drum;iron wooden drum

DIN 48204 Compact Aluminum ACSR Conductor 120mm2

 

ACSR conductor:

 Standard: ASTM B232 ,IEC61089, BS215 part2, DIN48204, BS EN50182, GB/T 1179-2008

 

 Brief Description:

ACSR conductor consists of a solid or stranded steel core surrounded by strands of aluminium (E.C. GRADE). 

ACSR Conductor may be manufactured for having a wide range of tensile strength as per requirement. 

The principal advantage of these conductors are high tensile strength and light weight with longer spans as well as 

with lesser supports. Due to the greater diameter of ACS Conductor a much higher corona limit can be obtained causing 

big advantages on high as well as extra high voltage overhead lines.

 

Package:In wooden drums or steel-wooden drums.

Date sheet:

Aluminum Conductors Steel Reinforced         ASTM B 232

 

Code name

Area

Stranding and wire diameter

Approx. overall diameter

Weight

Nominal breaking load

Nominal DC resistance at 20 deg.

 

Nominal

Alum.

Steel

Total

Alum.

Steel

Alum.

Steel

Total

 

 

AWG or MCM

mm2

mm2

mm2

mm

mm

mm

kg/km

kg/km

kg/km

kN

Ohm/km

 
 

TURKEY

6

13.29

2.19

15.48

6/1.68

1/1.68

5.04

37

17

54

5.24

2.1586

 

SWAN

4

21.16

3.55

24.71

6/2.12

1/2.12

6.36

58

27

85

8.32

1.3557

 

SWANATE

4

21.16

5.35

26.51

7/1.96

1/2.61

6.53

58

42

100

10.53

1.3557

 

SPARROW

2

33.61

5.61

39.22

6/2.67

1/2.67

8.01

92

44

136

12.7

0.8535

 

SPARATE

2

33.61

8.52

42.13

7/2.47

1/3.30

8.24

92

67

159

16.11

0.8535

 

RAVEN

1/0

53.48

8.9

62.38

6/3.37

1/3.37

10.11

147

69

216

19.32

0.5364

 

QUAIL

2/0

67.42

11.23

78.65

6/3.78

1/3.78

11.34

185

88

273

23.62

0.4255

 

PIGEON

3/0

85.03

14.19

99.22

6/4.25

1/4.25

12.75

233

110

343

29.41

0.3373

 

PENGUIN

4/0

107.23

17.87

125.1

6/4.77

1/4.77

14.31

294

139

433

37.06

0.2675

 

PARTRIDGE

266.8

135.16

22

157.16

26/2.57

7/2.00

16.28

374

172

546

50.29

0.2143

 

MERLIN

336.4

170.45

9.48

179.93

18/3.47

1/3.47

17.35

470

74

544

38.23

0.1691

 

LINNET

336.4

170.45

27.81

198.26

26/2.89

7/2.25

18.31

472

217

689

62.71

0.1699

 

ORIOLE

336.4

170.45

39.81

210.26

30/2.69

7/2.69

18.83

473

311

784

77.27

0.1704

 

IBIS

397.5

201.42

32.77

234.19

26/3.14

7/2.44

19.88

558

256

814

72.11

0.1438

 

LARK

397.5

201.42

46.97

248.39

30/2.92

7/2.92

20.44

560

367

927

88.69

0.1442

 

PELICAN

477

241.68

13.42

255.10

18/4.14

1/4.14

20.70

666

105

771

52.16

0.1193

 

FLICKER

477

241.68

31.29

272.97

24/3.58

7/2.39

21.49

670

245

915

76.66

0.1199

 

HAWK

477

241.68

39.42

281.10

26/3.44

7/2.67

21.79

670

308

978

86.65

0.1199

 

HEN

477

241.68

56.39

298.07

30/3.20

7/3.20

22.40

671

441

1112

105.34

0.1201

 

OSPREY

556.5

282.00

15.68

297.68

18/4.47

1/4.47

22.35

777

122

899

60.88

0.1022

 

PARAKEET

556.5

282.00

36.58

318.58

24/3.87

7/2.58

23.22

781

286

1067

88.22

0.1027

 

DOVE

556.5

282.00

45.94

327.94

26/3.72

7/2.89

23.55

781

359

1140

101.03

0.1027

 

EAGLE

556.5

282.00

65.81

347.81

30/3.46

7/3.46

24.21

783

515

1298

122.92

0.103

 

Aluminum Conductors Steel Reinforced           BS 215 Part 2

 

Code name

Area

Stranding and wire diameter

Approx. overall diameter

Weight

Nominal breaking load

Nominal DC resistance at 20 deg.

 

Nominal

Alum.

Steel

Total

Alum.

Steel

Alum.

Steel

Total

 

 

mm2

mm2

mm2

mm2

mm

mm

mm

kg/km

kg/km

kg/km

kN

Ohm/km

 

MOLE

10

10.62

1.77

12.39

6/1.50

1/1.50

4.50

29

14

43

4.14

2.076

 

SQUIRREL

20

20.94

3.49

24.43

6/2.11

1/2.11

6.33

58

27

85

7.88

1.368

 

GOPHER

25

26.25

4.37

30.62

6/2.36

1/2.36

7.08

72

34

106

9.61

1.093

 

WEASEL

30

31.61

5.27

36.88

6/2.59

1/2.59

7.77

87

41

128

11.45

0.9077

 

FOX

35

36.66

6.11

42.77

6/2.79

1/2.79

8.37

101

48

149

13.2

0.7822

 

FERRET

40

42.41

7.07

49.48

6/3.00

1/3.00

9

117

55

172

15.2

0.6766

 

RABBIT

50

52.88

8.82

61.7

6/3.35

1/3.35

10.05

145

69

214

18.35

0.5426

 

HORSE

70

73.37

42.8

116.17

12/2.79

7/2.79

13.95

203

335

538

61.2

0.3936

 

RACOON

75

79.2

13.2

92.4

6/4.10

1/4.10

12.3

217

103

320

27.2

0.3622

 

OTTER

80

83.88

13.98

97.86

6/4.22

1/4.22

12.66

230

109

339

28.80

0.3419

 

CAT

90

95.40

15.90

111.30

6/4.50

1/4.50

13.50

262

124

386

32.70

0.3007

 

HARE

100

105.00

17.50

122.50

6/4.72

1/4.72

14.16

288

137

425

36.00

0.2733

 

DOG

100

105

13.5

118.5

6/4.72

7/1.57

14.15

288

106

394

32.7

0.2733

 

TIGER

125

131.1

30.6

161.7

30/2.36

7/2.36

16.52

362

240

602

58

0.2202

 

WOLF

150

158

36.9

194.9

30/2.59

7/2.59

18.13

437

289

726

69.2

0.1828

 

LYNX

175

183.4

42.8

226.2

30/2.79

7/2.79

19.53

507

335

842

79.8

0.1576

 

CARACAL

175

184.2

10.3

194.5

18/3.61

1/3.61

18.05

507

80

587

41.1

0.1563

 

PANTHER

200

212

49.5

261.5

30/3.00

7/3.00

21

586

388

974

92.25

0.1363

 

BEAR

250

264

61.6

325.6

30/3.35

7/3.35

23.45

730

483

1213

111.1

0.1093

 

BISON

350

381.8

49.5

431.3

54/3.00

7/3.00

27

1056

388

1444

120.9

0.07573

 

DEER

400

429.3

100.2

529.5

30/4.27

7/4.27

29.89

1186

785

1971

178.5

0.06726

 

ZEBRA

400

428.9

55.6

484.5

54/3.18

7/3.18

28.62

1186

435

1621

131.9

0.0674

 

MOOSE

500

528.7

68.5

597.2

54/3.53

7/3.53

31.77

1462

537

1999

161.1

0.0547

 

 

ACSR Aluminum Conductor Steel-reinforced Power Cable

 Features:
1) It is manufactured according to IEC 60889/BS 215/ASTM B 232

2) rated voltage is 500KV or lowe

3) This series includes:

a) All aluminum conductors (AAC)

b) All aluminum alloy conductors (AAAC)

c) Aluminum conductor steel reinforced (ACSR)

d) Anti-corrosion ACSR

e) All steel conductor

4)Packing:Standard export wooden drums

(Aluminum Stranded Conductor ,Aluminum Conductor Steel-Reinforced,ACSR,bare wire,AAAC,Aluminum Stranded Conductor, bare wire,bare Aluminum wire, aluminum conductor )

Aluminium Conductor Steel Reinforced Henan ACSR factory

 

SPECIFICATIONS

ACSR bare conductor meets or exceeds the following ASTM specifications:
• B230 Aluminum 1350-H19 Wire for Electrical Purposes.
• B232 Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR).
• B498 Zinc-Coated (Galvanized) Steel Core Wire for Use in Overhead Electrical Conductors.
• B500 Metallic Coated Stranded Steel Core for Use in Overhead Electrical Conductors.

 

CONSTRUCTION

• Aluminum 1350-H19 wires, concentrically stranded about a steel core. Standard core wire for ACSR is class A galvanized.
• Class A core stranding is also available in zinc-5% aluminum-mischmetal alloy coating.
• For aluminum-clad (AW) ACSR, please refer to the ACSR/AW catalog sheet
• Additional corrosion protection is available through the application of grease to the core or infusion of the complete cable with grease.
• ACSR conductor is also available in non-specular.


The Details Of Products
 
The Headoffice
 
The Factory
 
 
The Conton Fair
 
Welcome your kind enquiry!!!
Tags: , ,

Contact us

 

 

 

Search