CU/XLPE/CWS/PVC/AWA/MDPE 240mm2 300mm2 400mm2 XLPE 11kV power cable price

Port: | Tianjin |
Payment Terms: | L/C,T/T,Western Union |
Supply Ability: | 5000 Kilometer/Kilometers per Month 11kV cable |
Place of Origin: | Hebei China |
Brand Name: | HAOHUA |
Model Number: | CU/XLPE/CWS/PVC/AWA/MDPE |
Insulation Material: | XLPE |
Type: | Medium Voltage |
Application: | Construction |
Conductor Material: | Copper |
Jacket: | PVC, PE or LSZH |
Amour for 11kV cable: | AWA |
Standard for 11kV cable: | IEC 60502, BS 6622, GB/T12706 |
Rated voltage: | 11kV XLPE cable |
Company nature: | Manufactury for 11kV cable |
Delivery Detail: | Shipped in 20 days after payment |
Packaging Detail: | Packed in wooden drums, steel drum or as per requirement for11kV cable |
CU/XLPE/CWS/PVC/AWA/MDPE 240mm2 300mm2 400mm2 XLPE 11kV power cable price
Nominal Section for 11kV cable
Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800
Operating Features FOR 11kV Ccable:
1)The maximum conductor operating temperature: 90°C
During short circuit (lasting less than 5 seconds) the maximum temperature of the cable conductor shall not be above 250°C
Environment temperature should be no lower than 0°C for laying the cable.
2)Bending Radius of the Cable:
Single Core Cable: Non Armored Cable 20D, Armored Cable 15D
Cores Cable: Non Armored Cable 15D, Armored Cable 12D.
Remarks: D means practical external diameter of the cable
Technical data of 11kV CU/XLPE/CWS/PVC/AWA/MDPE 1x240mm2 Power Cable
No. | Description | Unit | Particulars | ||
1 | Rated Voltage U0/U(Um) | kV | 6.35/11(12)kV | ||
2 | Standard applicable | IEC 60502-2 | |||
3 | Conductor Particulars; | ||||
i) | Nominal cross sectional area | mm2 | 240 | ||
ii) | Diameter of Conductor (approx.) | mm | 18.4 | ||
iii) | Number and diameter of individual wire | No./mm | 58/2.35 | ||
iv) | Material. (Copper/Aluminium) | Copper | |||
vi) | Shape. (Round/Shaped) | Round | |||
v) | Type | ||||
a) | Solid/Stranded | Stranded | |||
b) | Compacted/Uncompacted | Compacted | |||
vii) | Max. DC resistance of conductor at 20℃ | Ω/km | 0.0754 | ||
4 | Conductor Screen Particulars | ||||
i) | Material. (Compound/Tape) | Semi-conducting Compound | |||
ii) | Thickness. | mm | 0.8 | ||
iii) | Method of Application Lapped/Extruded | Extruded | |||
5 | Insulation Particulars; | ||||
i) | Material | XLPE | |||
ii) | Thickness; | ||||
a) | Nominal | mm | 3.4 | ||
b) | Minimum at a point. | mm | 2.96 | ||
iii) | Core Identification (Colour tape under metallic screen) | / | |||
6 | Insulation Screen Particulars | ||||
i) | Material. (Compound/Tape) | Semi-conducting Compound | |||
ii) | Thickness. | mm | 0.8 | ||
iii) | Method of Application Lapped/Extruded | Extruded | |||
7 | Metallic Screen Particulars | ||||
i) | Metallic type | Copper Wires + Copper Tape | |||
ii) | Nominal cross-section area of screen | mm2 | 130 | ||
iii) | No. of Cu screen wires/ Dia. of each wire | No./mm | 74/1.50 | ||
iv) | Number x thickness x width of tapes | mm | 1 x 0.10 x 20 | ||
No. | Description | Unit | Particulars | ||
8 | Innersheath | ||||
i) | Material | PVC | |||
ii) | Thickness | ||||
a) | Nominal | mm | 1.2 | ||
b) | Minimum at a point. | mm | 0.76 | ||
9 | Armour | ||||
i) | Type. (Wire/Tape) | Aluminium Wire Armour | |||
ii) | Wire/Tape (Diameter/Thickness) | 2.00 | |||
10 | Oversheath | ||||
i) | Material | MDPE | |||
ii) | Thickness | ||||
a) | Nominal | mm | 2.2 | ||
b) | Minimum at a point. | mm | 1.77 | ||
iii) | Colour | Black | |||
11 | Approximate overall diameter of the cable | mm | 44.1 | ||
12 | Approximate weight of cable | kg/km | 4672 | ||
13 | Minimum during installation bending radius | mm | 529 | ||
14 | High voltage test for 5min (21kV ) | No breakdown | |||
15 | Maximum allowable conductor temperature | ||||
i) | Full Load conditions | ℃ | 90 | ||
ii) | Short Circuit conditions | ℃ | 250 | ||
16 | Packing | ||||
i) | Drum Length | m | 500 | ||
ii) | Drum Dimension(D*d*B*b) | mm | 1600*800*1080*980 | ||
iii) | Net weigh of cable & Gross weight of drum with cable | kg | 2336&2596 | ||
iv) | Drum Material | Non-return Steel Wood Drum |
If you can't find the product you need in the list, please feel free contact me!!!
Packing | |||||
i) | Drum Length | m | 500 | ||
ii) | Drum Dimension(D*d*B*b) | mm | 1600*800*1080*980 | ||
iii) | Net weigh of cable & Gross weight of drum with cable | kg | 2336&2596 | ||
iv) | Drum Material | Non-return Steel Wood Drum |
Wendy Jiang- Sale engineer
TEL: 0086-531-88814697
FAX: 0086-531-88876156
MOB: 0086-18253153062
SKYPE:hongliangcablesales3
EMAIL: wendy(at)hldlcable.com
Send Your Inquiry Details in the Below for Free Sample, Click "Send" now!
- Next: copper conductor pvc insulated 6mm 10mm 16mm 25mm electric cable
- Previous: China manufacturer 8.7/15kV flame retardant 3 Core 150mm 185mm 240mm XLPE insulated power cable
Contact us
Search
You May Like
-
Factory Producing Cross Section 185mm2 240mm2 300mm2 10kV 3C/Cu/XLPE/STA/PVC XLPE Cable
-
0.6/1kV NYFGbY Copper conductor PVC/XLPE insulated SWA armored electrical cable size 240mm2
-
ZMS CABLE LV 0.6/1kv 240mm2 XLPE Insulated Steel Wire Armored Copper Conductor Cable
-
CU/XLPE/CWS/PVC/AWA/MDPE 240mm2 300mm2 400mm2 XLPE 11kV power cable price