copper or aluminum triplex service Drop abc cable Minex

Port: | Qingdao, any port in China |
Payment Terms: | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
Supply Ability: | 1000 Meter/Meters per Week |
Place of Origin: | Henan China |
Brand Name: | sanhe |
Model Number: | 6awg |
Insulation Material: | PVC |
Type: | High Voltage |
Application: | Overhead |
Conductor Material: | Aluminum alloy |
Jacket: | none |
Product name: | copper or aluminum triplex service Drop abc cable Minex |
Color: | Black Ect |
Certificate: | ISO9001 |
Key word: | Conductor |
Conductor: | Alulminum |
Package: | Steel Reel |
Conductor type: | Stranded Core |
Brand: | sanhe |
Delivery Time: | 15 Days |
Trade Term: | FOB |
Packaging Detail: | wooden drum, roll, coil |
copper or aluminum triplex service Drop abc cable Minex
Introduction of overhead insulated cable
Our overhead insulated cable have formed a system, such as single core, two-core, three-core and four-core. There are conductors of aluminum, copper or aluminum conductors steel-reinforced. We can manufacture the overhead insulated cable not only in accordance with China's standard GB12527-90 but also the other standards and special requirement by the customers.
Cable's characteristics
1) Rated voltage U:10kV
2) Installing temperature should not be below -200C.
3) Max.temperature when short circuit (Max.continuous time not more than
5sec):XLPE insulation 2500C
4) Max.admissible long -time operating temperature to conductor :
Max.admissible long -time operating temperature to the insulation of cable with loading structure:XLPE insulation 900C, High-density PE insulation 750C
5) admissible bending radius to cable:
6) Admissible bending radius to cable should be not less than 20(d+D)±5%mm.
Where:D-real overall diameter of cable (mm). d-real diameter of conductor (mm)
Application
Primarily used for overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltage of 600V pahse-to -pahse or less and at conductor temperatures not to exceed 750C for polyethylene insulated conductor or 900C for crossliked polyethlene (XLPE) insulated conductors.
Service drop cable meets or exceeds the following specifications:
1. Aluminum Wire ,1350-H19 for Electrical Purposes
2. Aluminum Conductor , Concentric-Lay-Stranded.
3. Aluminum Conductor , Concentric-Lay-Stranded,Coated Steel Reinforced(ACSR)
4. Concentric-Lay-Stranded6201-T81Conductors
5.Service drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76- 474.
Triplex Service Drop
Code word |
AWG or kcmil |
Bare Neutral Messenger |
Phase Conductor |
Weight kg/km |
||||
ALLOY |
Rated Strength Ibs |
AAC |
Insul Thick mm |
|||||
Number |
Dia mm |
Number |
Dia mm |
|||||
Minex |
2*6AWG+1*30.58 |
7 |
1.68 |
1110 |
1 |
4.11 |
1.14 |
152 |
Sandcrab |
2*1/0AWG+1*77.47 |
7 |
2.67 |
2800 |
7 |
3.12 |
1.52 |
504 |
Echinus |
2*1/0AWG+1*77.47 |
7 |
2.67 |
2800 |
19 |
1.89 |
1.52 |
505 |
Crayfish |
2*2/0AWG+1*97.65 |
7 |
3.00 |
3530 |
7 |
3.50 |
1.52 |
621 |
Sipho |
2*2/0AWG+1*97.65 |
7 |
3.00 |
3530 |
19 |
2.13 |
1.52 |
622 |
Fulgar |
2*3/0AWG+1*123.3G |
7 |
3.37 |
4460 |
19 |
2.39 |
1.52 |
767 |
Arca |
2*4/0AWG+1*155.4 |
7 |
3.78 |
5390 |
19 |
2.68 |
1.52 |
949 |
More packages for you to choose
production process of our factory
Prime Quality, Customer First
please contact me when you need.
E-mail: shcable010(at) cnzzcable.com.cn (at=@) |
||
TEL: +86 15617579707 | ||
Wechat: 15617579707 | ||
skype: +86 15617579707 | ||
Name: Echo Lu |
- Next: Multi-core power overhead abc cable Dachshund
- Previous: Duplex/Triplex/Quadruplex service drop ABC cable Mustang price
Contact us
Search
You May Like
-
BS standard 0.6/1kV 2/3/4/5 cores twist conductor XLPE insulation aerial bundle cable abc cable
-
Aerial bundle cable Overhead line electrical power cable 3x70mm2+54.6mm2+16mm2 ABC cable
-
ABC cable Aerial bundled cable Overhead cable 3x25 mm2+54.6 mm2+16 mm2
-
Power Transmission Line Electrical Power Cable AAC/AAAC/ACSR/ABC Cable