copper / aluminum cable types of electrical underground power cables

Port: | QINGDAO, SHANGHAI or as your require |
Payment Terms: | L/C,D/A,D/P,T/T,Western Union,MoneyGram |
Supply Ability: | 800 Kilometer/Kilometers per Month copper / aluminum cable |
Place of Origin: | Henan China |
Brand Name: | Hongda cable |
Model Number: | copper / aluminum cable |
Insulation Material: | XLPE |
Type: | Low Voltage |
Application: | Industrial |
Conductor Material: | Aluminum |
Jacket: | PVC |
Color: | Red/yellow/green/blue or as your request |
Application: | Industrail / family use |
Properties: | High safety & competitive price |
Standard: | CCC/ BS /ASTM /GB |
Voltage: | 0.6/1KV low voltgate |
Cores: | 1 core to 5 cores |
Size: | NA2XY |
Sheath: | ZR-PVC |
Conductor: | Stranded Round Compacted Copper |
Product name: | NA2XY Aluminium Conductor XLPE Insulated PVC Sheathed Cable |
Delivery Detail: | 10 days or depend on quantity for copper / aluminum cable |
Packaging Detail: | copper / aluminum cable types of electrical underground power cables is adopt for export wooden drum, wooden iron drum or other export standard package. We can also pack it according to your requirement. |
0.6/1 kV, NA2XY (Al / XLPE / PVC)
(Aluminium Conductor, XLPE Insulated, PVC Sheathed)
Standard Specification : SPLN 43 – 6 & IEC 60502 – 1
copper / aluminum cable types of electrical underground power cables
Applications
These cables are used for Power cable : Indoors, cable trunking, outdoors and burried in the ground, for power stations, industry and switchgear as well as for urban supply networks, if mechanical damage is unlikely.
Construction
Conductors | The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228. |
Insulation | XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90°C continuous operation. |
Assembly / Inner Covering | The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The material is compatible with the insulating material,The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound. |
Armour | Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request. |
Outer Sheath | Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request. |
Fire Performance of Cable Sheaths | Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2. |
Colour Code
Colour Code (1)
1 Core | Red or Black |
2 Cores | Red, Black |
3 Cores | Red, Yellow, Blue |
4 Cores | Red, Yellow, Blue, Black |
5 Cores | Red, Yellow, Blue, Black, Green |
Above 5 Cores | Black Cores with White numerals |
Colour Code (2)
1 Core | Brown or Blue |
2 Cores | Brown, Blue |
3 Cores | Brown, Black, Grey |
4 Cores | Blue, Brown, Black, Grey |
5 Cores | Green/Yellow, Blue, Brown, Black, Grey |
Above 5 Cores | Black Cores with White numerals |
Other colours can be manufactured upon request.
Cable Parameters
No. of Core
|
Nom. cross Section Area |
Single quantity of conductor |
Insu. Thick |
Sheath thick |
Approx. dia. Of cable |
D.C resistant((Ω/km) |
|
(mm2) |
(mm) |
(mm) |
(mm) |
Cu |
Al | ||
1 |
1.5~800 |
1~61 |
0.8~2.9 |
1.4~2.4 |
6.1~46.1 |
12.1~0.221 |
0~0.0367 |
2 |
1.5~400 |
1~61 |
0.8~2.6 |
1.8~2.8 |
10.5~56.0 |
119~8356 |
100~3320 |
3 |
1.5~400 |
1~61 |
0.8~2.6 |
1.8~3.0 |
10.9~60.6 |
142.0~12103.0 |
113.0~4869.0 |
4 |
2.5~400 |
1~61 |
0.8~2.6 |
1.8~3.2 |
12.7~70.0 |
232.0~16788 |
169~6708 |
5 |
2.5~400 |
1~61 |
0.8~2.6 |
1.8~3.6 |
13.6~87.0 |
272~21164 |
193~8564 |
3+1 |
4~400, 2.5~240 |
1~37 1~61 |
1.0~2.6 0.8~1.6 |
1.8~3.3 |
14.3~66.0 |
254~14562 |
211~5968 |
3+2 |
4~400, 2.5~240 |
1~61 1~37 |
1~2.6 0.8~1.6 |
1.8~3.3 |
15.2~78.2 |
345~18250 |
238~7666 |
4+1 |
4~400, 2.5~240 |
1~61 1~37 |
1~2.6 0.8~1.6 |
1.8~3.4 |
15.6~79.1 |
358~19928 |
251~8366 |
More product
ABC cable
APPLICATIONS Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
Get Quotation |
|
Power cable Application: The product applies to the lines of 0.6/1kv rated voltage , it is mainly used for electric transmission and transportation in high buildings,subways,power station ,entertainment places,inductrial enterprises and sea pertrol platform etc. , where a high intensity of cable laying and a strong flame-ratardant ability are required.
Get Quotation |
|
AAC
APPLICATIONS Classes 1 AA and A are used primarily for overhead transmission and primary and secondary distribution, where ampacity must be maintained and a lighter conductor (compared to ACSR) is desired, and when conductor strength is not a critical factor. Classes B and C are used primarily as bus, apparatus connectors and jumpers, where additional flexibility is required.
Get Quotation |
Packing:
Steel wooden drum (fumigation)
Cable length in each drum: 500m/1000m or as per actual cable length requirements.
Standard Packing :
- 10 – 800 sqmm supplied in wooden drum @ 1000 meters
- Length Tolerance per drum ± 2%
Drum size:
As per cable length and container size
*In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!
Shipping:
Port: Tianjin, Qingdao, or other ports as per your requireents.
Sea freight:
FOB/C&F/CIF quotation are all available.
Our service
we are one of the biggest manufacture in china mainland. We will give you a perfect shopping experience . If you need visit our factory , we will meet you at the airport or train station.
Also we can offer other service
Custom Merchandise:we can make cable as your need include the color ,size and so on.we also offer OEM .
Complete Course Tracking:we can offer you the service from the business begin to you get the cable and use it .
Hongda Cable Co–Professional Cable and Conductor Manufacturer
1) More than 18 years experience.
2) 10,000m² factory, 100 staffs, annual output 100,000 metic tons.
3)Sound Quality Control
(1) Material inspection;
(2) Manufacturing inspection;
(3) Finished products inspection;
(4) Inspection before delivery.
(5) Third party inspection.
(6) Inspection of storage at port of departure.
4) ISO Certificated.
5) Plenty of material and lobor gurantee the delivery prompt and price competitive.
6) 24/7 service.
Contact information
Any needs or question ,please contact us ,we will be more pleasure to service you.
We are looking forward to your inquiry and nice cooperaton.
- Next: 0.3 / 0.5KV Light Moveable Flexible Mining Cable
- Previous: ACSR aluminum conductor steel reinforced 556.5 mcm osprey conductor for transmission towers