China supplier AAC/AAAC conductor PE/XLPE Insulated ABC cable

Port: | Tianjin |
Payment Terms: | L/C,T/T,Western Union |
Supply Ability: | 5000 Kilometer/Kilometers per Month PE/XLPE Insulated ABC cable |
Place of Origin: | Hebei China |
Brand Name: | HAOHUA |
Model Number: | abc cable |
Insulation Material: | PE/XLPE/PVC |
Type: | Low Voltage |
Application: | Overhead |
Conductor Material: | Aluminum |
Jacket: | None |
Certificate: | CE, CCC,ISO9001certification |
Color: | as customer requirement |
Company nature: | Manufactury for PE/XLPE Insulated ABC cable |
Delivery Detail: | 7-20 working days after receiving the payment |
Packaging Detail: | PE/XLPE Insulated ABC cable should be supplied in steel/wooden drum. |
China supplier AAC/AAAC conductor PE/XLPE Insulated ABC cable
We can customize various types of cable in accordance with your requirements
Applications of PE/XLPE Insulated ABC cable
AAC/AAAC conductor PE/XLPE Insulated ABC cable as a new-type Aerial cable is used for transmitting electric power overhead,extensively used in rebuilding of urban and forest region electrical wire netting.It improves the safety and reliance of electrified wire netting.
Rated Voltage for PE/XLPE Insulated ABC cable :
UO/U 0.6/1kV,11kV,33kV
Type:Duplex Service Drop, Triplex Service Drop, Quadruplex Service Drop
a Duplex Service Drop
Applications:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.
b Triplex Service Drop
Applications: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .
c Quadruplex Service Drop
Applications: Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
Description of PE/XLPE Insulated ABC cable :
Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and
temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated cond-uctors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
Model and Specification of AAC/AAAC conductor PE/XLPE Insulated ABC cable
SPEC mm2 |
Conductor structure |
Insulation Material |
Insulation Thickness (mm) |
Approx overall diameter (mm) |
Approx weight (kg/km) |
|
Phase (compacted Al) |
Neutral (alloy) |
|||||
No./mm |
No./mm |
|||||
1*16+1*16 |
7/1.72 |
7/1.72 |
XLPE
(HDPE)
PVC |
1.2 |
12.5 |
110.1 |
1*25+1*25 |
7/2.15 |
7/2.15 |
1.2 |
14.9 |
163.9 |
|
1*35+1*35 |
7/2.54 |
7/2.54 |
1.4 |
17.5 |
229.0 |
|
1*50+1*50 |
7/2.92 |
7/2.92 |
1.4 |
20.1 |
300.0 |
|
1*70+1*70 |
19/2.15 |
19/2.15 |
1.4 |
23.6 |
423.2 |
|
1*95+1*95 |
19/2.54 |
19/2.54 |
1.6 |
27.6 |
585.4 |
|
2*16+1*16 |
7/1.72 |
7/1.72 |
1.2 |
14.2 |
175.8 |
|
2*25+1*25 |
7/2.15 |
7/2.15 |
1.2 |
16.7 |
258.4 |
|
2*35+1*35 |
7/2.54 |
7/2.54 |
1.4 |
19.7 |
361.2 |
|
2*50+1*50 |
7/2.92 |
7/2.92 |
1.4 |
22.5 |
472.1 |
|
2*70+1*70 |
19/2.15 |
19/2.15 |
1.4 |
26.1 |
658.3 |
|
2*95+1*95 |
19/2.54 |
19/2.54 |
1.6 |
30.5 |
908.2 |
|
3*16+1*16 |
7/1.72 |
7/1.72 |
1.2 |
16.3 |
241.5 |
|
3*25+1*25 |
7/2.15 |
7/2.15 |
1.2 |
19.1 |
353.6 |
|
3*35+1*35 |
7/2.54 |
7/2.54 |
1.4 |
22.5 |
493.5 |
|
3*50+1*50 |
7/2.92 |
7/2.92 |
1.4 |
25.7 |
644.1 |
|
3*70+1*70 |
19/2.15 |
19/2.15 |
1.4 |
29.7 |
895.2 |
|
3*95+1*95 |
19/2.54 |
19/2.54 |
1.6 |
34.6 |
1233.5 |
Aerial Cable, Aerial bundle cable, ABC cable Picture
w 35kV Stee
Wendy Jiang- Sale engineer
TEL: 0086-531-88814697
FAX: 0086-531-88876156
MOB: 0086-18253153062
SKYPE:hongliangcablesales3
EMAIL: wendy(at)hldlcable.com
Send Your Inquiry Details in the Below for Free Sample, Click "Send" now!
- Next: 11kV 33kV 185mm2 240mm2 300mm SWA armoured XLPE insulated Power Cable
- Previous: Underground application 25mm 35mm 50mm 70mm 95mm 120mm power cable
Contact us
Search
You May Like
-
BS standard 0.6/1kV 2/3/4/5 cores twist conductor XLPE insulation aerial bundle cable abc cable
-
Aerial bundle cable Overhead line electrical power cable 3x70mm2+54.6mm2+16mm2 ABC cable
-
ABC cable Aerial bundled cable Overhead cable 3x25 mm2+54.6 mm2+16 mm2
-
Power Transmission Line Electrical Power Cable AAC/AAAC/ACSR/ABC Cable