BS5308 Part 2 Type pair insrumentation PVC-IS-OS-SWA-PVC/ RE-Y(St)Y PIMF SWAY Cable

BS5308 Part 2 Type pair insrumentation PVC-IS-OS-SWA-PVC/ RE-Y(St)Y PIMF SWAY Cable
Port: qingdao
Payment Terms: L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability: 1000 Kilometer/Kilometers per Week good quality on Instrument Cable
Place of Origin: Henan China
Brand Name: hongda
Model Number: instrumentation cable
Shielding: Foil
Conductor Material: Copper
Jacket: PVC
Insulation Material: PVC
Model: Instrumentation Cable
Type: armored xlpe cable
model2: insulated Instrument Cable
standard: bs5308 IEC 602270
Insulation: pvc/pe/xlpe
Jacket/sheath: pvc/pe/xlpe
Voltage: 300/500
Quality control: ISO9001
Sample: available
Delivery Detail: 20 days
Packaging Detail: wooden/metal wooden drums or according to your require

 BS5308 Part 2 Type pair insrumentation PVC-IS-OS-SWA-PVC/ RE-Y(St)Y PIMF SWAY  Cable

 

Application

Cables

The armoured versions (Part 2 Type 2) are generally used when the risk of mechanical damage is increased. The galvanised steel wire armour provides excellent protection. Generally used within industrial process manufacturing plants for communication, data and voice transmission signals and services, Also used for the interconnection of electrical equipment and instruments, typically in chemical or petrolchemical industry. The armored versions are generally use for outdoor installation for direct burial or installed in the duct and suitable for wet and damp areas.

 

Construction

Conductor

Annealed or tinned copper, sizes: 0.5mm2 and 0.75mm2 mulitistranded(Class 5), 1.5mm2 multistranded(Class 2) to BS6360

Insulation

PVC (polyvinyl chloride),type TI1 to BS 6746

Pairing

Two insulated conductors uniformly twisted together with a lay not exceeding 100mm

Colour code

Multipair cables:See technical information

Individual screen

Aluminium/polyester tape is applied over each pair metallic side down in contact with tinned copper drain wire, 0.5mm2

Binder tape

PETP transparent tape

Collective screen

Inner Sheath

Amour

Outer sheath

Sheath colour

Aluminium/polyester tape is applied over the laid up pairs metallic side down in contact with tinned copper drain wire, 0.5mm2

PVC (polyvinyl chloride), type TM 1 to BS 6746

Galvanized steel wire armour

PVC Sheath, type TM 1 or type 6 to BS 6746

Black or blue

PETP transparent binder tape PE inner sheath Tinned copper drain wire Galvanized steel wire armour

Annealed or tinned copper, sizes: 0.5mm2 and 0.75mm2 mulitistranded(Class 5), 0.5 mm2, 1.0 mm2 solid(Class 1), 1.5mm2 or 2.5mm2, multistranded(Class 2) to BS6360 PE (Polyethylene) type 03 to BS6234 Two insulated conductors uniformly twisted together with a lay not exceeding 100mm

See technical information

PETP transparent tape Aluminium/polyester tape is applied over the laid up pairs metallic side down in contact with tinned copper drain wire, 0.5mm2 PE (Polyethylene) type 2C or type 03 to BS6234 Galvanized steel wire armour PVC Sheath, type TM 1 to BS 6746

Black or blue

Standard of insulated cable:
It is manufacture under GB/T12706-2002 standard(The same as IEC60502).

 

UP TO 600/1000V PE INSULATION INSTRUMENTATION CABLE 
Generally to IEC Standard No.: BS 5308-1978 
Maximum working temperature 70° C 
PE or PVC/Multi-pair/ Collectively screened/Unarmoured/PVC 
PE or PVC/Multi-pair/ Individually & Collectively screened/Unarmoured/PVC 
PE or PVC/Multi-pair/ Collectively screened/Galvanized steel wire armoured/PVC 
PE or PVC/Multi-pair/ Individually & Collectively screened/ Galvanized steel wire armoured/PVC 
PE or PVC/Multi-pair/ Collectively screened/Galvanized steel wire braiding/PVC 
PE or PVC/Multi-pair/ Individually & Collectively screened/ Galvanized steel wire braiding/PVC

 

Voltage rating
600/1000V

Temperature rating
-20°C to +60°C

Bending radius 
Single core: 10 x overall diameter 
Multicores: 8 x overall diameter

 

Instrument Cable Application:

For use in installations designed to connect electrical instrumentation circuits and provide communication services in and around process plants. Suitable for direct burial applications.

Specification of instrument cable:

Instrument Cable Conductors:

0.5mm – class 5 flexible copper

0.75mm – class 5 flexible copper

1.5mm – class 2 stranded copper

Insulation: PE (Polyethylene)

Screen: CAM (Collective Aluminium Mylar)

Bedding: PE (Polyethylene)

Armour: SWA

Outer Sheath: PVC (Polyvinyl-Chloride)

Voltage Rating: 300/500volts

Temp. Rating: 65 C

Flexible  instrumentation multi-core cables about PVC insulated and twisted parallel cable

 

 

Standard: National Standard GB/T 5023; IEC60227

Rated Voltage: 300/300V;

 Construction: 1. annealed flexible copper conductor

                       2.PVC insulated 

 Application: used for electric appliance, electric tool, electric instruments and lighting, automatic system 

Application of insulated cable Instrument Cable :
It is used to transmit and distribute power on the power line of A. C. Rated voltage 0.6/1kV.

XLPE insulated electric cable Instrument Cable 0.6/1kv
norminalsectional area  insulati-on thicknes sheath thickness(mm) overal diameter of cable (mm) D.C resistance of conductor(km)                 current rating
in air(A) direct in soil(A)
cu Al cu Al cu Al
1×1.5 0.7 1.5 6 <=12.1 <=12.1 30 25 45 35
1×4 0.7 1.5 7 <=7.41 <=7.41 45 35 60 50
1×6 0.7 1.5 7 <=3.08 <=4.61 55 45 70 55
1×35 0.9 1.5 12 <=0.524 <=0.868 175 140 190 150
1×50 1 1.5 13 <=0.387 <=0.641 210 170 225 180
1×70

1

.1

1.5 14 <=0.268 <=0.443 270 215 280 225
1×95 1.1 1.5 16 <=0.193 <=0.320 340 275 335 270
1×120 1.2 1.5 18 <=0.153 <=0.253 400 320 380 305
1×150 1.4 2 21 <=0.124 <=0.206 460 370 425 340
1×185 1.6 2 23 <=0.0991 <=0.164 530 415 480 375
1×240 1.7 2 25 <=0.0754 <=0.125 625 490 555 435
                 
3×1.5 0.7 1.5 10 <=12.1 <=12.1 25 25 30 30
3×2.5 0.7 1.5 11 <=7.41 <=12.1 30 25 35 30
3×4 0.7 1.5 12 <=4.61 <=7.41 40 30 50 40
               
Attention: We can provide more info than above data, if needed.The above are just some examples.

 

Using features of insulated cable Instrument Cable :
1. Rated voltage: Uo/U: 0.6/1kV
2. No. Of core: Single-core, Two-core, Three-core, Four-core, Five-core, Three core and earth(Three primary conductor and one Neutral conductor), Three core and two((Three primary conductor and Two Neutral conductor), Four core and earth((Four primary conductor and One Neutral conductor).
3. The highest allowed operating temperature of conductor for long-term working is 70oC. In short-circuit (Max. Long-term is no more than 5 seconds). The highest temperature for conductor is no more than 160oC.
4. D. C. Resistance of the conductor complies with the stipulations of GB/T3956-1997.
5. The environment temperature should be no lower than 0oC when lay. Otherwise it should be preheated.

Model: insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable, insulated cable

 

welcome to inquire us  Instrument Cable

Tags: , ,

Contact us

 

 

 

Search

You May Like

  • No related articles