BS EN 50183 Aster 570 All Aluminum Alloy Conductors AAAC

BS EN 50183 Aster 570 All Aluminum Alloy Conductors AAAC
Port: qingdao, Shanghai, Ningbo etc.
Payment Terms: L/C,T/T,Western Union,MoneyGram,BS EN 50183 conductor
Supply Ability: 1000 Kilometer/Kilometers per Month BS EN 50183 conductor
Place of Origin: Henan China
Brand Name: Hongda
Model Number: Conductor AAAC ASTER 570
Insulation Material: No insulated
Type: Medium Voltage
Application: Overhead
Conductor Material: Aluminum
Jacket: No sheath
Product name: BS EN 50183 Aster 570 All Aluminum Alloy Conductors AAAC
Standard: BS EN 50183
Size: Aster 570, 570.2mm2
Application: Transmission line, transmission towers, and other structures
Advantage: economy, dependability, and strength to weight ratio
BS EN 50183: All Aluminum Alloy Conductors AAAC
Specification: 570.2mm2
Conductor: AAAC
Certificate: ISO9001, CCC
Sample order: Available
Delivery Detail: 10 days
Packaging Detail: export wooden drums ,metal drums or your requirement for BS EN 50183 conductor
Product Description

 

BS EN 50183 Aster 570 All Aluminum Alloy Conductors AAAC

 

Conductor AAAC ASTER 570 Application

Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum-alloy to achieve a high strength to weight ratio; affords good sag characteristics.

 

(1) AAAC conductors are extensively used for overhead distribution and transmission lines adjacent to ocean coast lines where there can be a problem of corrosion in the steel of an ACSR construction.

 

(2) The aluminum alloy conductors are used in replace of single-layer ACSR conductors to reduce power loss in overhead distribution and transmission lines, when replacing the aluminum conductor steel reinforced, the AAAC can save 5-8% of the construction cost.

 

(3) AAAC referred to have higher strength but lower conductivity than pure aluminum being lighter, alloy conductors can sometimes be used to advantage in replace of the more conventional ACSR.

 

Features

Aluminum alloy conductors have a number of advantages over the use of the ACSR or AAC (All aluminum conductors)

. Lower power losses than for equivalen single aluminum-layer ACSR conductors. ( The inductive effect of the steel core in the ACSR is eliminated).

  • Simpler fittings than those required for ACSR.
  • Excellent corrosion resistance in environments conductive to galvanic corrosion in ACSR.
  • Strength and sag approximately the same for equivalent 6/1 and 26/7 ACSR conductors.
  • Outside diameters are the same as for strandard ACSR conductors, permitting interchangeability of fittings.
  • Greater resistance to abrasion than that for 1350 wires in all aluminum or ACSR conductors.
  • High tensile strength as compared to AAC conductor.
  • Higher conductivity as compared to ACSR conductor.

Conductor AAAC ASTER 570 STANDARDS

  • ASTM B399
  • BS EN50183
  • BS 3242
  • DIN 48201
  • IEC 61089

Notes

  • Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
  • Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq.ft sun, 0.5 coefficients of emissivity and absorption. 

     

    AAAC – All Aluminum Alloy Conductors BS EN 50183

    Area No. of Wires Diameter Weight Rated Strength D.C. Resistance at 20°C Standard Length
    mm2 Wire Cond kg.km kN ohm/km m±5%
    mm mm
    15.9 7 1.70 5.1 43.3 4.69 2.0701 3000
    24.2 7 2.10 6.3 66.2 7.15 1.3566 3000
    34.4 7 2.50 7.5 93.8 10.14 0.9572 3000
    49.5 7 3.00 9.0 135.1 14.6 0.6647 3000
    48.3 19 1.80 9.0 132.7 14.26 0.6841 3000
    65.8 19 2.10 10.5 180.7 19.41 0.5026 2000
    93.3 19 2.50 12.5 256.0 27.51 0.3546 2000
    117.0 19 2.80 14.0 321.2 34.51 0.2827 2000
    147.1 37 2.25 15.8 405.3 43.40 0.2256 2000
    181.6 37 2.50 17.5 500.3 53.58 0.1827 2000
    242.5 61 2.25 20.3 670.3 71.55 0.1373 2000
    299.4 61 2.50 22.5 827.5 88.33 0.1112 2000
    400.1 61 2.89 26.0 1105.9 118.04 0.0832 2000
    499.8 61 3.23 29.1 1381.4 147.45 0.0666 2000
    626.2 91 2.96 32.6 1737.7 184.73 0.0534 2000
    802.1 91 3.35 36.9 2225.8 236.62 0.0417 2000
    999.7 91 3.74 41.1 2774.3 294.91 0.0334 2000

All Aluminum Alloy Conductors (AAAC) BS EN 50183

Designation Area Stranding Overall Dia. Nominal Breaking Load D.C. Resistance at 20°C Standard Weight Standard Length
mm2 No. mm mm kN ohm/km kg/km m±5%
ASTER 22 22.0 7 2.00 6.00 7.15 1.4989 60.0 4000
ASTER 34.4 34.4 7 2.50 7.50 11.17 0.9593 93.8 3000
ASTER 54.6 54.6 7 3.15 9.45 17.73 0.6042 148.9 3000
ASTER 75.5 75.5 19 2.25 11.3 24.55 0.4388 207.4 3000
ASTER 117 117.0 19 2.80 14.0 38.02 0.2833 321.2 2000
ASTER 148 148.1 19 3.15 15.8 48.12 0.2239 406.5 2000
ASTER 181.6 181.6 37 2.50 17.5 59.03 0.1831 500.3 2000
ASTER 228 227.8 37 2.80 19.6 74.04 0.1460 627.6 2000
ASTER 288 288.3 37 3.15 22.1 93.71 0.1154 794.3 2000
ASTER 366 366.2 37 3.55 24.9 115.36 0.0908 1008.9 2000
ASTER 570 570.2 61 3.45 31.1 185.33 0.0585 1576.0 2000
ASTER 851 850.7 91 3.45 38.0 276.47 0.0394 2360.7 2000
ASTER 1144 1143.5 91 4.00 44.0 360.22 0.0293 3173.4 2000
ASTER 1600 1595.9 127 4.00 52.0 502.72 0.0210 4427.5 2000

 

 

Our Services

 

 Conductor AAAC ASTER 570

Insection Equipments:

Conductor AAAC ASTER 570

Process equipments:

 

Certification:

 

 

Packaging & Shipping

Packing: 

Steel wooden drum (fumigation)
Cable length in each drum: 500m/1000m or as per actual cable length requirements.

Drum size:
As per cable length and container size
*In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!

Shipping:
Port: Tianjin, Qingdao, or other ports as per your requireents.

Sea freight:
FOB/C&F/CIF quotation are all available.

 

 

FAQ

Q 1: I didn’t find the cable I need in this page?
A: Dear Friend, we supply customized service. So, you can contact me directly for the as follows information, I will reply you asap!

Q 2: What’s your Minimum Order Quantity?
A: You are advised to please confirm with us as it is based on the specification of the cables. Normally, it is 100m for small electric wires. 500 to 1000 per drum for power cable.

Q 3: What’s your delivery time?
A: It depends on whether we just has the stock for your type. Or, it takes about 7 – 15 days for normal orders.

Q 4: How can I get a sample to check your quality?
A: After price confirmation, you can require for sample to check our quality. Sample is free, but the freight charge should be paid.

Q: What is your terms of payment ?
A: Payment<=1000USD, 100% in advance. Payment>=1000USD, 30% T/T in advance ,balance before shipment.

Company Information

Company Profile

Hongda cable Co., Ltd. is one of the most professional cable & wire producer under modern enterprise system in China, which was founded in 1988, integrating scientific research, development, production and sales. The company mainly produces 1-35 kV power cable, ABC cable, AAC, AAAC, ACSR.

Our advantages

1.  With more than 17 years manufacturing experience, our products are strictly in accordance with ISO, CE, UL and BV;

2.  Good cost-control system, with highly-competitive prices;

3.  Strong and Professional R&D team to meet your specific needs;

4.  Fast delivery&reliable products are always the reason why you choose us.

Contact Information

Contact information

 

Any needs or question ,please contact us ,we will be more pleasure to service you.

Skype ID: xinyuanyy
Cellphone/WhatsApp/Wechat/ICQ: +86 158 3829 0725

Facebook: xin.yuan.73307

We are looking forward to your inquiry and nice cooperaton.

Tags: , ,

Contact us

 

 

 

Search

You May Like

  • No related articles