BS EN 50182 NF-C 34125 All Aluminum Alloy AAAC ASTER Conductor

Port: | qingdao, Shanghai, Ningbo etc. |
Payment Terms: | L/C,T/T,Western Union,MoneyGram,AAAC ASTER Conductor |
Supply Ability: | 1000 Kilometer/Kilometers per Month AAAC ASTER Conductor |
Place of Origin: | Henan China |
Brand Name: | Hongda |
Model Number: | AAAC ASTER Conductor |
Insulation Material: | No insulated |
Type: | Medium Voltage |
Application: | Overhead |
Conductor Material: | Aluminum |
Jacket: | No sheath |
Product name: | BS EN 50182 NF-C 34125 All Aluminum Alloy AAAC ASTER Conductor |
Standard: | BS EN 50183, NF-C 34125 |
Size: | 22 to 1600mm2 |
Application: | Transmission line, transmission towers, and other structures |
Advantage: | economy, dependability, and strength to weight ratio |
NF-C 34125: | All Aluminum Alloy Conductors AAAC |
Specification: | 22 to 1600mm2 |
Conductor: | AAAC |
Certificate: | ISO9001, CCC |
Sample order: | Available |
Delivery Detail: | 10 days |
Packaging Detail: | export wooden drums ,metal drums or your requirement for AAAC ASTER Conductor |
BS EN 50182 NF-C 34125 All Aluminum Alloy AAAC ASTER Conductor
AAAC ASTER Conductor Application
Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum-alloy to achieve a high strength to weight ratio; affords good sag characteristics.
(1) AAAC conductors are extensively used for overhead distribution and transmission lines adjacent to ocean coast lines where there can be a problem of corrosion in the steel of an ACSR construction.
(2) The aluminum alloy conductors are used in replace of single-layer ACSR conductors to reduce power loss in overhead distribution and transmission lines, when replacing the aluminum conductor steel reinforced, the AAAC can save 5-8% of the construction cost.
(3) AAAC referred to have higher strength but lower conductivity than pure aluminum being lighter, alloy conductors can sometimes be used to advantage in replace of the more conventional ACSR.
Features
Aluminum alloy conductors have a number of advantages over the use of the ACSR or AAC (All aluminum conductors)
. Lower power losses than for equivalen single aluminum-layer ACSR conductors. ( The inductive effect of the steel core in the ACSR is eliminated).
- Simpler fittings than those required for ACSR.
- Excellent corrosion resistance in environments conductive to galvanic corrosion in ACSR.
- Strength and sag approximately the same for equivalent 6/1 and 26/7 ACSR conductors.
- Outside diameters are the same as for strandard ACSR conductors, permitting interchangeability of fittings.
- Greater resistance to abrasion than that for 1350 wires in all aluminum or ACSR conductors.
- High tensile strength as compared to AAC conductor.
- Higher conductivity as compared to ACSR conductor.
AAAC ASTER Conductor STANDARDS
- ASTM B399
- BS EN50183
- BS 3242
- DIN 48201
- IEC 61089
Notes
- Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
- Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq.ft sun, 0.5 coefficients of emissivity and absorption.
AAAC – All Aluminum Alloy Conductors BS EN 50183
Area No. of Wires Diameter Weight Rated Strength D.C. Resistance at 20°C Standard Length mm2 Wire Cond kg.km kN ohm/km m±5% mm mm 15.9 7 1.70 5.1 43.3 4.69 2.0701 3000 24.2 7 2.10 6.3 66.2 7.15 1.3566 3000 34.4 7 2.50 7.5 93.8 10.14 0.9572 3000 49.5 7 3.00 9.0 135.1 14.6 0.6647 3000 48.3 19 1.80 9.0 132.7 14.26 0.6841 3000 65.8 19 2.10 10.5 180.7 19.41 0.5026 2000 93.3 19 2.50 12.5 256.0 27.51 0.3546 2000 117.0 19 2.80 14.0 321.2 34.51 0.2827 2000 147.1 37 2.25 15.8 405.3 43.40 0.2256 2000 181.6 37 2.50 17.5 500.3 53.58 0.1827 2000 242.5 61 2.25 20.3 670.3 71.55 0.1373 2000 299.4 61 2.50 22.5 827.5 88.33 0.1112 2000 400.1 61 2.89 26.0 1105.9 118.04 0.0832 2000 499.8 61 3.23 29.1 1381.4 147.45 0.0666 2000 626.2 91 2.96 32.6 1737.7 184.73 0.0534 2000 802.1 91 3.35 36.9 2225.8 236.62 0.0417 2000 999.7 91 3.74 41.1 2774.3 294.91 0.0334 2000
All Aluminum Alloy Conductors (AAAC) BS EN 50183
Designation | Area | Stranding | Overall Dia. | Nominal Breaking Load | D.C. Resistance at 20°C | Standard Weight | Standard Length | |
mm2 | No. | mm | mm | kN | ohm/km | kg/km | m±5% | |
ASTER 22 | 22.0 | 7 | 2.00 | 6.00 | 7.15 | 1.4989 | 60.0 | 4000 |
ASTER 34.4 | 34.4 | 7 | 2.50 | 7.50 | 11.17 | 0.9593 | 93.8 | 3000 |
ASTER 54.6 | 54.6 | 7 | 3.15 | 9.45 | 17.73 | 0.6042 | 148.9 | 3000 |
ASTER 75.5 | 75.5 | 19 | 2.25 | 11.3 | 24.55 | 0.4388 | 207.4 | 3000 |
ASTER 117 | 117.0 | 19 | 2.80 | 14.0 | 38.02 | 0.2833 | 321.2 | 2000 |
ASTER 148 | 148.1 | 19 | 3.15 | 15.8 | 48.12 | 0.2239 | 406.5 | 2000 |
ASTER 181.6 | 181.6 | 37 | 2.50 | 17.5 | 59.03 | 0.1831 | 500.3 | 2000 |
ASTER 228 | 227.8 | 37 | 2.80 | 19.6 | 74.04 | 0.1460 | 627.6 | 2000 |
ASTER 288 | 288.3 | 37 | 3.15 | 22.1 | 93.71 | 0.1154 | 794.3 | 2000 |
ASTER 366 | 366.2 | 37 | 3.55 | 24.9 | 115.36 | 0.0908 | 1008.9 | 2000 |
ASTER 570 | 570.2 | 61 | 3.45 | 31.1 | 185.33 | 0.0585 | 1576.0 | 2000 |
ASTER 851 | 850.7 | 91 | 3.45 | 38.0 | 276.47 | 0.0394 | 2360.7 | 2000 |
ASTER 1144 | 1143.5 | 91 | 4.00 | 44.0 | 360.22 | 0.0293 | 3173.4 | 2000 |
ASTER 1600 | 1595.9 | 127 | 4.00 | 52.0 | 502.72 | 0.0210 | 4427.5 | 2000 |
AAAC ASTER Conductor
Insection Equipments:
AAAC ASTER Conductor
Process equipments:
Certification:
Packing:
Steel wooden drum (fumigation)
Cable length in each drum: 500m/1000m or as per actual cable length requirements.
Drum size:
As per cable length and container size
*In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!
Shipping:
Port: Tianjin, Qingdao, or other ports as per your requireents.
Sea freight:
FOB/C&F/CIF quotation are all available.
Q 1: I didn’t find the cable I need in this page?
A: Dear Friend, we supply customized service. So, you can contact me directly for the as follows information, I will reply you asap!
Q 2: What’s your Minimum Order Quantity?
A: You are advised to please confirm with us as it is based on the specification of the cables. Normally, it is 100m for small electric wires. 500 to 1000 per drum for power cable.
Q 3: What’s your delivery time?
A: It depends on whether we just has the stock for your type. Or, it takes about 7 – 15 days for normal orders.
Q 4: How can I get a sample to check your quality?
A: After price confirmation, you can require for sample to check our quality. Sample is free, but the freight charge should be paid.
Q: What is your terms of payment ?
A: Payment<=1000USD, 100% in advance. Payment>=1000USD, 30% T/T in advance ,balance before shipment.
Company Profile
Hongda cable Co., Ltd. is one of the most professional cable & wire producer under modern enterprise system in China, which was founded in 1988, integrating scientific research, development, production and sales. The company mainly produces 1-35 kV power cable, ABC cable, AAC, AAAC, ACSR.
Our advantages
1. With more than 17 years manufacturing experience, our products are strictly in accordance with ISO, CE, UL and BV;
2. Good cost-control system, with highly-competitive prices;
3. Strong and Professional R&D team to meet your specific needs;
4. Fast delivery&reliable products are always the reason why you choose us.
Contact information
Any needs or question ,please contact us ,we will be more pleasure to service you.
Skype ID: xinyuanyy
Cellphone/WhatsApp/Wechat/ICQ: +86 158 3829 0725
Facebook: xin.yuan.73307
We are looking forward to your inquiry and nice cooperaton.
- Next: NF-C 34125 Aluminium conductor steel reinforced – ACSR CANNA Conductor
- Previous: 21/35 kV Medium voltage AL/XLPE/CWS/PVC Electric cable with the concentric conductor screen
Contact us
Search
You May Like
- No related articles