ASTM standard 0.6/1KV ABC cable 3x2AWG+2AWG AAC+ACSR

Port: | Qingdao |
Payment Terms: | L/C,D/A,D/P,T/T |
Supply Ability: | 10000 Kilometer/Kilometers per Month |
Place of Origin: | Henan China |
Brand Name: | Jinshui |
Model Number: | ABC |
Insulation Material: | XLPE or PE |
Type: | Low Voltage |
Application: | Overhead |
Conductor Material: | Aluminum |
Jacket: | None |
Rated Voltage: | 0.6/1KV, 11KV, 33KV |
Cores: | Duplex, Triplex, Quadruplex |
Type of phase conductor: | AAC |
Type of neutral conductor: | AAC, AAAC, ACSR |
Standard: | IEC, ASTM |
Certificates: | ISO9001, CE, CCC |
Packaging Detail: | Export wooden drum, steel-wooden drum as customer's requests |
Specifications
Standard: National Standard IEC and ASTM
Rated Voltage: 0.6/1KV, 11KV, 33KV
Construction: Phase conductor: aluminum stranded(AAC)
Neutral conductor: aluminum stranded(AAC), aluminum alloy stranded(AAAC), aluminum conductor steel reinforced(ACSR)
Insulation: XLPE or PE
Application: The cables are designed for aerial power lines and room-entrance wires with voltage up to and including 0.6/1KV.
Uesd for overhead service application such as street linghting, outdoor lighting and temporary service for cunstruction.which improves the safety and reliance of electrified wire netting.
1 Type:Duplex Service Drop, Triplex Service Drop, Quadruplex Service Drop
a Duplex Service Drop
Applications:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.
b Triplex Service Drop
Applications: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .
c Quadruplex Service Drop
Applications: Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
2 Construction
a Phase Conductor construction:The phase conductor is aluminum alloy 1350-H19 hard-drawn, compressed concentric-lay-stranded.
b Neutral Conductor Construction
Cable assemblies are available with the following neutral conductors:
Aluminum conductors, coated-steel reinforced (ACSR), concentric-lay-stranded
Aluminum alloy 1350-H19 hard-drawn, concentric-lay-stranded
Aluminum alloy 6201-T81, concentric-lay-stranded
c Insulation Material
The standard insulation on the phase conductor is black low-density crosslinked polyethylene (XLPE)
Alternatively, black linear low-density polyethylene (LDPE) insulation with a 75°C temperature rating is available upon request.
SPEC mm2 | conductor structure | Approx. | ||||||
Phase | Neutral(Bare ACSR) | insulation | insulation | Overall | Approx. | packing | ||
(Compacted AL) | Aluminium | Steel | material | Thickness | Diameter | Weight | Meters Per | |
(No./mm) | (No./mm) | (No./mm) | (mm) | (mm) | (kg/km) | Drum | ||
1×16+1×16 | 7/1.72 | 6/1.72 | 1/1.72 | XLPE | 1.2 | 12.5 | 121.9 | 250-4000m |
1×25+1×25 | 7/2.15 | 6/2.15 | 1/2.15 | 1.2 | 14.9 | 182.2 | 250-4000m | |
1×35+1×35 | 7/2.54 | 6/2.54 | 1/2.54 | 1.4 | 17.5 | 254.7 | 250-3500m | |
1×50+1×50 | 7/2.92 | 6/2.92 | 1/2.92 | 1.4 | 20.1 | 333.9 | 250-3000m | |
1×70+1×70 | 19/2.15 | 12/2.15 | 17/2.15 | 1.4 | 23.6 | 382.2 | 250-3000m | |
1×95+1×95 | 19/2.54 | 12/5.24 | 17/5.24 | 1.6 | 27.6 | 528.2 | 250-3000m | |
2×16+1×16 | 7/1.72 | 6/1.72 | 1/1.72 | (HDPE) | 1.2 | 14.2 | 187.6 | 250-4000m |
2×25+1×25 | 7/2.15 | 6/2.15 | 1/2.15 | 1.2 | 16.7 | 273.8 | 250-3500m | |
2×35+1×35 | 7/2.54 | 6/2.54 | 1/2.54 | 1.4 | 19.7 | 386.9 | 250-3500m | |
2×50+1×50 | 7/2.92 | 6/2.92 | 1/2.92 | 1.4 | 22.5 | 506 | 250-3000m | |
2×70+1×70 | 19/2.15 | 12/2.15 | 7/2.15 | 1.4 | 26.1 | 617.2 | 250-3000m | |
2×95+1×95 | 19/2.54 | 12/5.24 | 7/5.24 | 1.6 | 30.5 | 850.9 | 250-3000m | |
3×16+1×16 | 7/1.72 | 6/1.72 | 1/1.72 | 1.2 | 16.3 | 253.3 | 250-3500m | |
3×25+1×25 | 7/2.15 | 6/2.15 | 1/2.15 | 1.2 | 19.1 | 371.9 | 250-3500m | |
3×35+1×35 | 7/2.54 | 6/2.54 | 1/2.54 | 1.4 | 22.5 | 519.1 | 250-3000m | |
3×50+1×50 | 7/2.92 | 6/2.92 | 1/2.92 | 1.4 | 25.7 | 678.1 | 250-3000m | |
3×70+1×70 | 19/2.15 | 12/2.15 | 7/2.15 | 1.4 | 29.7 | 1024.3 | 250-3000m | |
2×95+1×95 | 19/2.54 | 12/2.54 | 7/2.54 | 1.6 | 34.6 |
Code Name |
Phase Conductor |
Bare Neutral Messenger |
Weight Per 1000ft (lbs) |
Ampacity(amps) |
||||||
Size AWG |
Stranding |
Insulation Thickness(mls) |
Size AWG |
Stranding |
Breaking Strength(lbs) |
XLPE |
Poly |
XLPE |
Poly |
|
6201 ALLOY NEUTRAL-MESSENGER |
||||||||||
Minex |
6 |
Solid |
45 |
6 |
7 |
1,110 |
106.6 |
102.9 |
85 |
70 |
Hippa |
6 |
7 |
45 |
6 |
7 |
1,110 |
113.2 |
105.7 |
85 |
70 |
Prawn |
4 |
Solid |
45 |
4 |
7 |
1,760 |
158.4 |
154.1 |
115 |
90 |
Barnacles |
4 |
7 |
45 |
4 |
7 |
1,760 |
168.3 |
158.2 |
115 |
90 |
Shrimp |
2 |
7 |
45 |
2 |
7 |
2,800 |
253.7 |
239.7 |
150 |
120 |
Gammarus |
1/0 |
7 |
60 |
1/0 |
7 |
4,460 |
411.7 |
386.0 |
205 |
160 |
Leda |
1/0 |
19 |
60 |
1/0 |
7 |
4,460 |
402.7 |
386.0 |
205 |
160 |
Dungenese |
2/0 |
7 |
60 |
2/0 |
7 |
5,390 |
506.8 |
476.3 |
235 |
185 |
Cyclops |
2/0 |
19 |
60 |
2/0 |
7 |
5,390 |
495.3 |
476.3 |
235 |
185 |
Dlustra |
3/0 |
19 |
60 |
3/0 |
7 |
6,790 |
611.4 |
589.1 |
275 |
215 |
Lepas |
4/0 |
19 |
60 |
4/0 |
7 |
8,560 |
757.1 |
730.5 |
315 |
245 |
- Next: Overhead Conductor(ACSR, AAC, AAAC, ACSS/TW, ACCC, AACSR, ACAR, OPGW)Bare Conductor