as/nzs 4961 concentrico de cobre cable electric wire concentric cable from Through the pull test
Port: | Qingdao or Other port |
Payment Terms: | L/C,D/A,D/P,T/T,Western Union |
Supply Ability: | 300000 Meter/Meters per Month |
Place of Origin: | Henan China |
Brand Name: | Sanhe |
Model Number: | concentric cable |
Insulation Material: | XLPE ,PE,PVC |
Type: | Low Voltage |
Application: | Construction |
Conductor Material: | 8000 AL or AL or copper |
Jacket: | PE , PVC,XLPE |
MOQ: | 1000m |
Inspect: | each drum |
Price: | Factory price |
Voltage: | 600V to 2200V |
Delivery time: | 7-15 Days |
Certificate: | ISO,TUV |
Name: | concentrico cable |
Conductor: | 8000Al,AL. Copper |
Insulation: | XLPE ,PE ,PVC |
Sheath: | XLPE ,PE ,PVC |
Packaging Detail: | Wooden drum |
as/nzs 4961 concentrico de cobre cable electric wire concentric cable from Through the pull test
Our company founded in 2008, with own factory, have more business experience.
Ⅰ Applications
The concentric cable is used as electric service entrance from the power distribution network until meter panel ,and as feeder cable from the meters panel until the panel or general distribution panel,just as it is specified in the National electric code,
this type of conductor can be used in dry and wet place,directly buried or outdoor;it’s maximum temperature of operation is 70℃( PVC or PE insulation) or 90℃ (XLPE insulation) and it’s voltage of service for all the applications is 600V.
Ⅱ Specification
1. Conductor : Copper or Aluminum or 8000 series Aluminum Alloy
2. Insulation: PVC or PE or XLPE
3. Concentric neutral: Copper or Aluminum or 8000 series Aluminum Alloy
4. Sheath: PVC or PE or XLPE
Conductores concentricos de Aluminio
2×#6 | 3×#6 | 2×#4 | 3×#4 | 4×#4 | 3×#2 | 4×#2 | ||
Fase | No hilos | 7 | ||||||
Diametro hilo (mm) |
1.55 | 1.96 | 2.47 | |||||
Diametro fase (mm) |
4.66 | 5.88 | 7.42 | |||||
Seccion fase (mm2) |
13.3 | 21.2 | 33.6 | |||||
Espesor aislamiento (mm) |
1.14 |
|||||||
Diametro sobre aislamiento (mm) |
6.94 | 8.16 | 9.70 | |||||
Neutro |
Cobertura (%) | ≥90 | ||||||
No hilos | 25 | 65 | 26 | 65 | 103 | 65 | 103 | |
Diametro hilo (mm) |
0.81 | 0.51 | 1.02 | 0.64 | 0.51 | 0.81 | 0.64 | |
AWG | 20 | 24 | 18 | 22 | 24 | 20 | 22 | |
Seccion (mm2) |
12.97 | 13.33 | 21.3 | 21.11 | 21.12 | 33.7 | 33.44 | |
Espesor cubierta (mm) | 1.14 | 1.52 | 1.14 | 2.03 | 1.52 | 2.03 | 2.03 | |
Diametro exterior aproximado (mm) |
11.14 | 11.2×18.2 | 12.7 | 13.8×21.9 | 22 | 15.6×25.3 | 26 |
Over 20 Types of packages to offer your customers
Click here : " Send enquiry "
Instricity inspection by professinals is guaranteed
Click here : " Send enquiry "
You can choose many more models
Best Quality, Factory price, Please Choose us.
Click here : " Send enquiry "
Major Buyers Rely on our services
Click here : " Send enquiry "
Over 2000 Customers have come to us
Please send enquiry, Do not be hesitate to contact me.
Click here : " Send enquiry "
Zhengzhou Sanhe cable.,Ltd.
WhatsApp: | +86 13683803874 | |
Tel: | +86-371-69176007 | |
Fax: | +86-371-69176006 | |
Wechat: | chen1368380038 | |
Email: | shcable017(at)cnzzcable.com.cn | |
Name: | Jack chen |
- Next: Copper/PVC/PVC cable Flat/Round Electrical insulated wire
- Previous: 4 core 95mm lv abc cable (cable abc) stock lot
Contact us
Search
You May Like
-
China concentric neutral cable manufacturer electrical power cable 0.6/1 kv
-
Aluminum /XLPE/PVC Conductor aluminum 8000 Concentrico 2x10mm2 2x16mm2 3x10mm2 4x16mm2
-
0.6/1kV, 2x10mm2 2x16mm2 3x10mm2 Aluminum Aerial Concentric Service Cable Concentrico Cable
-
Medium Voltage 8.7/15kV 12/20kV 18/30kV Concentric Split Single Phase Service cable
-
600V copper/aluminum XLPE insulated PVC sheath NYCY concentric cable/concentrico cable power cable