Aluminum armoured cable

| Port: | China Main Port | 
| Payment Terms: | L/C,D/P,T/T | 
| Supply Ability: | 500 Kilometer/Kilometers per Month | 
| Place of Origin: | Henan China | 
| Brand Name: | Jinshui | 
| Model Number: | 4*185mm2 | 
| Insulation Material: | PVC | 
| Type: | Low Voltage | 
| Application: | Underground | 
| Conductor Material: | Aluminum | 
| Jacket: | PVC | 
| Material: | aluminum | 
| Delivery Detail: | After received deposits 10-20days | 
| Packaging Detail: | wooden drum,Iron-wooden drum | 
Specifications
1 Conductor:Copper or Aluminium
2 Insulation:PVC 
3 Voltage:Low Voltage
4 Standard:IEC 60502,GB/T 12706
Technical Parameters of our Power Cable
1). Standard: IEC60502; GB/T12706;IEC 60840;IEC62067;GB/T 11017;GB/Z 18890
2). Detailed description or construction:
* Conductor: compacted or uncompacted copper or aluminium
* Insulation: Polyvinyl chloride (PVC)
* Filler: Polypropylene filament with lapped binding tape
* Binder: Binding tape
* Inner sheath: Polyvinyl chloride (PVC)
* Armour: Galvanized steel wire armored (SWA) or steel tape armored (STA)
*Sheath: Polyvinyl chloride (PVC)
3). The rated voltages U0/U(Um) of the cables considered in this standard are as follows:
U0/U(Um) =0.6/1(1.2)
4). Voltage:0.6/1kV,
In the voltage designation of cables U0/U(Um):
* U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
* U is the rated power frequency voltage between conductors for which the cable is designed;
* Um is the maximum value of the "highest system voltage" for which the equipment maybe used.
5). Application:
For laying indoors, in tunnel or cable trench with large difference of level able to bear external mechanical forces.
6). Marking: According to the customers' requirements
7). Nominal cross-sectional areas:
1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2,
240mm2, 300mm2, 400mm2, 500mm2, 630mm2, 800mm2.
| Type | Designation | Applications | |
| VV YJV VLV YJLV | Copper conductor, PVC ,XLPE insulated, PVC sheathed power cable Aluminium conductor, PVC ,XLPE insulated, PVC sheathed power cable | For laying indoors, in tunnel or cable trench, unable to bear external mechanical forces. Single core cable is not permissible to lay in magnetic duct. | |
| VY YJY VLY YJLY | Copper conductor, PVC,XLPE insulated, PE sheathed power cable Aluminium conductor, PVC ,XLPE insulated, PE sheathed power cable | ||
| VV22 YJV22 VLV22 YJLV22 | Copper conductor, PVC ,XLPE insulated, steel tape armoured, PVC sheathed power cable Aluminium conductor, PVC ,XLPE insulated, steel tape armoured, PVC sheathed power cable | For laying indoors, in tunnel, in cable trench or direct in ground, a ble to bear external mechanical forces, but unable to bear large pulling force. | |
| VV23 YJV23 VLV23 YJLV23 | Copper conductor, PVC ,XLPE insulated, steel tape armoured, PE sheathed power cable Aluminium conductor, PVC ,XLPE insulated, steel tape armoured, PE sheathed power cable | ||
| VV32 YJV32 VLV32 YJLV32 | Copper conductor, PVC ,XLPE insulated, steel wire armoured, PVC sheathed power cable Aluminium conductor, PVC ,XLPE insulated, steel wire armoured, PVC sheathed power cable | For laying indoors, in tunnel, in cable trench or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force. | |
| VV33 YJV33 VLV33 YJLV33 | Copper conductor, PVC ,XLPE insulated, steel wire armoured, PE sheathed power cable Aluminium conductor, PVC ,XLPE insulated, steel wire armoured, PE sheathed power cable | ||
| Note: The armoured single core cables is only used for D.C. system. As for A.C. system, non-magnetic armour material should be applied. | |||
- Next: high voltage XLPE Insulation PVC jacket Power Cable
- Previous: IEC standard Aluminum conductor PVC insulated electrical wire
 