Aluminium/polyester tape Screen NF M 87-202 EGPF Instrumentation Cables

Aluminium/polyester tape Screen NF M 87-202 EGPF Instrumentation Cables
Port: Shanghai, Qingdao, Ningbo, Shenzhen
Payment Terms: L/C,D/P,T/T,Western Union,MoneyGram,instrumentation cables specification
Supply Ability: 1500 Kilometer/Kilometers per Month French Standard NF M 87-202 EGSF Instrumentation Cables
Place of Origin: Henan China
Brand Name: Hongda
Model Number: NF M 87-202
Shielding: Foil
Conductor Material: Copper
Jacket: PVC
Insulation Material: PVC
Applications: used for safety for the transmission
Conductor: Annealed or tinned copper
Sizes: 0.5mm~2 and 1.5mm~2
Insulation: PVC (70 mm maximum pair length)
Voltage Rating: 300/500V
Outer Sheath: PVC (Flame retardant, sunlight, mineral oil and hydrocarton resistant)
Maximum Voltage: 250V
Voltage Test: 2000V
Operating Temperature: -40°C/+90°C
Installation Temperature: MAX+50°C
Packaging Detail: Pack in drum, other packaging can be customized for instrumentation cables specification
Product Description

 

Aluminium/polyester tape Screen NF M 87-202 EGPF Instrumentation Cables

NF M 87-202 EGPF

NF M 87-202 EGPF

NF M 87-202 Instrumentation Cables Applications

These NF M 87-202 EGPF instrumentation cables are used for safety extra-low use in petroleum and petrochemical units particularly for the transmission of a.c. or d.c. analogue signals, They lead cover brings an enhanced resistance to aromatics hydrocarbons.

NF M 87-202 Instrumentation Cables Construction

Conductor Solid or Stranded copper conductor
Insulation PVC (70 mm maximum pair length)
Binder tape Polyster tape
Collective Screen Aluminium/polyester tape
Binder tape PETP transparent tape
Outer Sheath PVC (Flame retardant, sunlight, mineral oil and hydrocarton resistant)
Outer Sheath Colour Light-blue

 

 

NF M 87-202 Instrumentation Cables Core identification

Colours Natural Red Blue Yellow
1 pair    
1 triple  
1 quad

Natural cores printed with pair/triple number 

NF M 87-202 Instrumentation Cables Standards References

  • NF M 87-202
  • UTE C 32-014
  • NF C 32-020
  • IEC 60332-1
  • IEC 60332-3-24

NF M 87-202 Instrumentation Cables Characteristics

Voltage Rationg 300/500V
Operating Temperature -40°C/+90°C
Installation Temperature MAX+50°C
Maximum Voltage 250V
Voltage Test 2000V

 

Maximum conductor d.c. Resistance

 

Conductor Size Ohm/km at +20°C
1/0.80mm(0.50 sqmm) 37.50
7/0.40mm(0.88 sqmm) 21.40
7/0.53mm(1.50 sqmm) 12.50

 

NF M 87-202 Instrumentation Cables Capacitance between cond. (nf/km)

  • 0.5 sqmm ≤ 145
  • 0.88 sqmm ≤ 160
  • 1.50 sqmm ≤ 180

 

NF M 87-202 Instrumentation Cables Type/codification

 

1 Serie Number of pairs, triples or quads / 01 to 27
2 Serie Lay up in pair(IP) ,triple (IT) , quads (IQ)
3 Serie Core section 05 (0.5mm^2) , 09 (0.88 mm^2) or 15(1.5mm^2)
4 Serie Overall screen(EG) or individual screen + overall screen(EI)
5 Serie Mechanical protection: without armour (SF), with armour (FA), with lead + armour(PF)

  

NF M 87-202 Instrumentation Cables Dimensions and Weight

NF M 87-202 Number of beams x cross section Cond. mm^2 Outer Diameter(mm) Weight(kg/km)
      Min. Max.  
01 IQ 05 EGPF 1X4X0.50 0.50 11.30 12.60 453
02 IP 05 EGPF 2X2X0.50 0.50 10.60 11.90 401
03 IP 05 EGPF 3X2X0.50 0.50 13.70 15.70 635
07 IP 05 EGPF 7X2X0.50 0.50 16.30 18.70 840
12 IP 05 EGPF 12X2X0.50 0.50 19.40 22.20 1160
19 IP 05 EGPF 19X2X0.50 0.50 22.90 26.30 1550
27 IP 05 EGPF 27X2X0.50 0.50 25.90 19.80 1855
01 IQ 09 EGPF 1X4X0.88 0.88 12.70 14.60 575
01 IP 09 EGPF 1X2X0.88 0.88 11.70 13.40 500
02 IP 09 EGPF 2X2X0.88 0.88 11.80 13.20 485
03 IP 09 EGPF 3X2X0.88 0.88 16.80 18.50 759
07 IP 09 EGPF 7X2X0.88 0.88 20.80 22.90 1136
12 IP 09 EGPF 12X2X0.88 0.88 25.20 27.80 1605
19 IP 09 EGPF 19X2X0.88 0.88 30.00 33.10 2185
27 IP 09 EGPF 27X2X0.88 0.88 34.30 37.90 2798
03 IP 09 EGPF 3X2X0.88 0.88 16.20 18.60 825
07 IP 09 EGPF 7X2X0.88 0.88 19.90 22.90 1205
12 IP 09 EGPF 12X2X0.88 0.88 24.20 27.80 1740
19 IP 09 EGPF 19X2X0.88 0.88 28.80 33.00 2300
27 IP 09 EGPF 27X2X0.88 0.88 33.00 37.80 2910
01 IP 15 EGPF 1X2X1.50 1.50 12.70 14.10 546
03 IP 15 EGPF 3X2X1.50 1.50 18.00 19.80 887
07 IP 15 EGPF 7X2X1.50 1.50 22.60 24.90 1362
12 IP 15 EGPF 12X2X1.50 1.50 27.70 30.60 2039
19 IP 15 EGPF 19X2X1.50 1.50 33.20 36.60 2783
27 IP 15 EGPF 27X2X1.50 1.50 37.80 41.70 3556
01 IT 05 EGPF 01X3X0.50 0.50 10.90 12.20 421
07 IT 05 EGPF 7X3X0.50 0.50 18.50 20.40 959
12 IT 05 EGPF 12X3X0.50 0.50 22.30 24.60 1353
19 IT 05 EGPF 19X3X0.50 0.50 26.30 29.00 1838
01 IQ 09 EGPF 1X4X0.88 0.88 13.00 14.40 573
01 IT 09 EGPF 1X3X0.88 0.88 12.00 13.70 530
07 IT 09 EGPF 7X3X0.88 0.88 23.10 25.50 1396
12 IT 09 EGPF 12X3X0.88 0.88 28.20 31.10 2071
19 IT 09 EGPF 19X3X0.88 0.88 33.60 37.00 2821
01 IT 15 EGPF 1X3X1.50 1.50 13.10 14.60 594
07 IT 15 EGPF 7X3X1.50 1.50 25.40 28.00 1785
12 IT 15 EGPF 12X3X1.50 1.50 30.80 33.90 2526
19 IT 15 EGPF 19X3X1.50 1.50 37.00 40.80 3617

 

Related Picture:

 

Certifications

 

Packaging & Shipping

Packing: 

Steel wooden drum (fumigation)
Cable length in each drum: 500m/1000m or as per actual cable length requirements.

Drum size:
As per cable length and container size
*In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!

Shipping:
Port: Tianjin, Qingdao, or other ports as per your requireents.

Sea freight:
FOB/C&F/CIF quotation are all available.

Contact Information

Contact information

 

Any needs or question ,please contact us ,we will be more pleasure to service you.

 

We are looking forward to your inquiry and nice cooperaton.

 

Tags: , ,

Contact us

 

 

 

Search

You May Like

  • No related articles